SERVICE DATA
| Radiator cap | Relief valve opening pressure: STD Minimum | 93-123 kPa (0.95-1.25 kgf/cm 2 ,13.5-17.8 psi) 78 kPa (0.8 kgf/cm 2 ,11.4 psi) |
|---|---|---|
| Electric cooling fan | Rotating amperage: at 20° C (68° F) Cooling fan computer wire harness amperage | 9.2-11.0A 9-14V |
| Thermostat | Valve opening temperature Valve lift at 95°C(203°F) | 80-84°C(176-183°F) 10 mm (0.39 in.) or more |
SERVICE DATA SPECIFICATIONS