HOW TO PROCEED WITH TROUBLESHOOTING [01/2012 - ]
HINT
Use these procedures to troubleshoot the clock system.
- VEHICLE BROUGHT TO WORKSHOP NEXT: Go to next step
- INSPECT BATTERY VOLTAGE Standard voltage 11 to 14 V If the voltage is below 11 V, recharge or replace the battery before proceeding. NEXT: Go to next step
- PROBLEM SYMPTOMS TABLE Refer to the Problem Symptoms Table. Refer to «PROBLEM SYMPTOMS TABLE [01/2012 - ]»(ref-604039-S16709572492014031100000) . RESULT Result Proceed to Fault is not listed in problem symptoms table A Fault is listed in problem symptoms table B B --> Go to step 5 A: Go to next step
- OVERALL ANALYSIS AND TROUBLESHOOTING Terminals of ECU. Refer to «TERMINALS OF ECU [01/2012 - ]»(ref-603988-S34817283392014031100000) NEXT: Go to next step
- ADJUST, REPAIR OR REPLACE NEXT --> END
PROBLEM SYMPTOMS TABLE [01/2012 - ]
HINT
Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.
| Symptom | Suspected Area | Refer To |
|---|---|---|
| Clock is not displayed | Multi-display power source circuit | Refer to Multi-display Power Source Circuit |
| Clock time is very incorrect | Clock loses or gains time | |
| Replace multi-media module receiver assembly | Refer to REMOVAL [01/2012 - ] | |
| Nighttime clock illumination does not operate | Illumination circuit | Refer to Illumination Circuit |
| Replace multi-display assembly | Refer to REMOVAL [01/2012 - ] |
CLOCK SYSTEM