Contents Section: Engine Control Systems All sections

Engine Control System (Service Specifications): Other Lexus LX J200 рестайлинг

SERVICE DATA [01/2012 - ]

Standard resistance4 (THA) - 5 (E2)20°C (-4°F)12.5 to 16.9 kohms
20°C (68°F)2.19 to 2.67 kohms
60°C (140°F)0.50 to 0.68 kohms

MAF METER (INTAKE AIR TEMPERATURE SENSOR)

Standard resistance1 - 220°C (68°F)6.9 to 7.9 ohms

CAMSHAFT TIMING OIL CONTROL VALVE

Standard resistance1 - 2Approximately 20°C (68°F)2.32 to 2.59 kohms
Approximately 80°C (176°F)0.310 to 0.326 kohms

ENGINE COOLANT TEMPERATURE SENSOR

Standard resistance1 (M-) - 2 (M+)20°C (68°F)0.3 to 100 ohms

THROTTLE CONTROL MOTOR

Standard resistance1 - 220°C (68°F)120 to 280 kohms

KNOCK SENSOR

Standard resistance1 (HA1A) - 2 (+B)20°C (68°F)1.6 to 3.2 ohms

AIR FUEL RATIO SENSOR (FOR BANK 1 SENSOR 1)

Standard resistance1 (HA2A) - 2 (+B)20°C (68°F)1.6 to 3.2 ohms

AIR FUEL RATIO SENSOR (FOR BANK 2 SENSOR 1)

Standard resistance1 (HT1B) - 2 (+B)20°C (68°F)11 to 16 ohms

HEATED OXYGEN SENSOR (FOR BANK 1 SENSOR 2)

Standard resistance1 (HT2B) - 2 (+B)20°C (68°F)11 to 16 ohms

HEATED OXYGEN SENSOR (FOR BANK 2 SENSOR 2)

Recommended spark plugDENSO made: SK20HR11
Correct electrode gap for new spark plug1.0 to 1.1 mm (0.039 to 0.043 in.)
Maximum electrode gap for used spark plug1.3 mm (0.051 in.)
Standard insulation resistance10 Mohms or higher

SPARK PLUG