INSTALLATION
Installation is in the reverse of removal (See REMOVAL ).
Scheme 147
Scheme 148
- CONNECT CHARGING HOSE TO MANIFOLD GAUGE SET Tighten the nuts by hand. CAUTION: Do not connect the wrong hoses.
- CONNECT QUICK DISCONNECT ADAPTERS TO CHARGING HOSES Tighten the nuts by hand.
- CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE SET
- REMOVE CAPS FROM SERVICE VALVES ON REFRIGERANT LINES
- CONNECT QUICK DISCONNECT ADAPTERS TO SERVICE VALVES HINT: Push the quick disconnect adapter onto the service valve, then slide the sleeve of the quick disconnect adapter downward to lock it.
Scheme 149
- CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE SET
- DISCONNECT QUICK DISCONNECT ADAPTERS FROM SERVICE VALVES ON REFRIGERANT LINE HINT: Slide the sleeve of the quick disconnect adapter upward to unlock the adapter and remove it from the service valve.
- INSTALL CAPS TO SERVICE VALVES ON REFRIGERANT LINE