DIODE ASSEMBLY
- Place diode (rectifier) assembly on bench. Connect ohmmeter positive lead to positive (+) terminal and negative lead to each rectifier terminal. (Scheme 7) Reverse ohmmeter leads and check again. Continuity should exist in only one direction.
- Connect ohmmeter positive lead to each rectifier terminal and negative lead to each negative (-) terminal. Reverse ohmmeter leads and check again. Continuity should exist in only one direction. If continuity is not as specified, replace diode assembly.
Scheme 7
OVERHAUL
Note. For overhaul procedures (Scheme 8), (Scheme 9) or (Scheme 10).