INTRODUCTION
Mode 6 is designed to allow access to the results of onboard diagnostic monitoring tests of specific components/systems that are not continuously monitored. These systems include the catalytic converter, EVAP system, oxygen sensor, oxygen sensor heater, EGR system, secondary AIR system, and sometimes misfire.
Mode 6 data is output from the PCM/ECM in hexadecimal form. The $ sign indicates a hexadecimal number. Depending on the software in the scanner, the output could be displayed in hexadecimal numbers (no conversion), raw data (conversion to decimal numbers), or measurable values (applying conversion factor to raw data).
Before reading mode 6 information, ensure that the monitor for the information you are accessing has run to completion. If the monitor is not complete, the mode 6 data will not be accurate.
ES 350
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8A | Multiply by 0.00012 | V | Rich to Lean response rate deterioration level |
| $01 | $8A | Multiply by 0.00012 | V | Lean to Rich response rate deterioration level |
| $01 | $90 | Multiply by 0.001 | Second | Rich to Lean delay level |
| $01 | $90 | Multiply by 0.001 | Second | Lean to Rich delay level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel cut |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8A | Multiply by 0.00012 | V | Rich to Lean response rate deterioration level |
| $05 | $8A | Multiply by 0.00012 | V | Lean to Rich response rate deterioration level |
| $05 | $90 | Multiply by 0.001 | Second | Rich to Lean delay level |
| $05 | $90 | Multiply by 0.001 | Second | Lean to Rich delay level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel cut |
| $06 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $42 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 1 Sensor 2 |
| $46 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 2 Sensor 2 |
REAR HO2S HEATER
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles-Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle-Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles-Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle-Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles-Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle-Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles-Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle-Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles-Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle-Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles-Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle-Total |
MISFIRE
GS 350
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8A | Multiply by 0.00012 | V | Rich to Lean response rate deterioration level |
| $01 | $8A | Multiply by 0.00012 | V | Lean to Rich response rate deterioration level |
| $01 | $90 | Multiply by 0.001 | Second | Rich to Lean delay level |
| $01 | $90 | Multiply by 0.001 | Second | Lean to Rich delay level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8A | Multiply by 0.00012 | V | Rich to Lean response rate deterioration level |
| $05 | $8A | Multiply by 0.00012 | V | Lean to Rich response rate deterioration level |
| $05 | $90 | Multiply by 0.001 | Second | Rich to Lean delay level |
| $05 | $90 | Multiply by 0.001 | Second | Lean to Rich delay level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8B | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $06 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles-Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle-Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles-Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle-Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles-Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle-Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles-Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle-Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles-Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle-Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles-Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle-Total |
MISFIRE
GS 450h
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8E | Multiply by 0.001 | No dimension | A/F sensor deterioration level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8E | Multiply by 0.001 | No dimension | A/F sensor deterioration level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $06 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
| $3D | $D8 | Multiply by 0.001 | KPa | Test value for canister small leak (P1420) |
| $3D | $D9 | Multiply by 0.001 | KPa | Test value for canister gross leak (P1421) |
| $3D | $DA | Multiply by 0.001 | KPa | Test value for fuel tank small leak (P1422) |
| $3D | $DB | Multiply by 0.001 | KPa | Test value for fuel tank gross leak (P1423) |
| $3D | $DC | Multiply by 0.001 | KPa | Test value for fuel vapor-containment valve close stuck (P2451) |
| $3D | $DD | Multiply by 0.001 | KPa | Test value for fuel vapor-containment valve open stuck (P2450) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles-Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle-Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles-Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle-Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles-Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle-Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles-Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle-Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles-Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle-Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles-Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle-Total |
MISFIRE
GS 460
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8E | Multiply by 0.001 | No dimension | A/F sensor deterioration level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8E | Multiply by 0.001 | No dimension | A/F sensor deterioration level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $06 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles-Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle-Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles-Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle-Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles-Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle-Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles-Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle-Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles-Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle-Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles-Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle-Total |
| $A8 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 7: Misfire counts for last ten driving cycles-Total |
| $A8 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 7: Misfire counts for last/current driving cycle-Total |
| $A9 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 8: Misfire counts for last ten driving cycles-Total |
| $A9 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 8: Misfire counts for last/current driving cycle-Total |
MISFIRE
GX 460
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $06 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $31 | $BD | Multiply by 0.01 | KPa | Delta Manifold Absolute Pressure |
EXHAUST GAS RECIRCULATION SYSTEM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $42 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 1 Sensor 2 |
| $46 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 2 Sensor 2 |
REAR HO2S HEATER
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $71 | $E1 | Multiply by 0.01 | G/sec. | AIR amount for AIR insufficient |
| $71 | $E2 | Multiply by 0.01 | KPa | Averaged AIR pressure for AIR pump stuck ON |
| $71 | $E3 | Multiply by 0.01 | KPa | Averaged AIR pressure for AIR pump stuck OFF |
| $71 | $E4 | Multiply by 0.01 | KPa | Test value for AIR control valve ON |
| $71 | $E5 | Multiply by 0.01 | KPa | Test value for AIR control valve OFF |
| $71 | $EA | Multiply by 0.01 | KPa | Test value for AIR valve stuck OFF |
SECONDARY AIR INJECTION (AIR) - FOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $72 | $E1 | Multiply by 0.01 | G/sec. | Test value for AIR insufficient |
| $72 | $E4 | Multiply by 0.01 | KPa | Test value for AIR control valve ON |
| $72 | $E5 | Multiply by 0.01 | KPa | Test value for AIR control valve OFF |
SECONDARY AIR INJECTION (AIR) - FOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles- Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle- Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles- Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle- Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles- Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle- Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles- Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle- Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles- Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle- Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles- Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle- Total |
| $A8 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 7: Misfire counts for last ten driving cycles- Total |
| $A8 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 7: Misfire counts for last/current driving cycle- Total |
| $A9 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 8: Misfire counts for last ten driving cycles- Total |
| $A9 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 8: Misfire counts for last/current driving cycle- Total |
MISFIRE
HS 250h
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1 SENSOR 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $42 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 1 Sensor 2 |
REAR HO2S HEATER
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles- Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle- Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles- Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle- Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles- Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle- Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles- Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle- Total |
MISFIRE
IS F
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $06 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles- Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle- Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles- Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle- Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles- Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle- Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles- Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle- Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles- Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle- Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles- Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle- Total |
| $A8 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 7: Misfire counts for last ten driving cycles- Total |
| $A8 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 7: Misfire counts for last/current driving cycle- Total |
| $A9 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 8: Misfire counts for last ten driving cycles- Total |
| $A9 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 8: Misfire counts for last/current driving cycle- Total |
MISFIRE
IS 250
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8A | Multiply by 0.00012 | V | Rich to Lean response rate deterioration level |
| $01 | $8A | Multiply by 0.00012 | V | Lean to rich response rate deterioration level |
| $01 | $90 | Multiply by 0.001 | Second | Rich to Lean delay level |
| $01 | $90 | Multiply by 0.001 | Second | Lean to rich delay level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $02 | $8F | Multiply by 0.003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8A | Multiply by 0.00012 | V | Rich to Lean response rate deterioration level |
| $05 | $8A | Multiply by 0.00012 | V | Lean to rich response rate deterioration level |
| $05 | $90 | Multiply by 0.001 | Second | Rich to Lean delay level |
| $05 | $90 | Multiply by 0.001 | Second | Lean to rich delay level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $06 | $8F | Multiply by 0.003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles-Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle-Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles-Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle-Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles-Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle-Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles-Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle-Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles-Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle-Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles-Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle-Total |
MISFIRE
IS 350
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8A | Multiply by 0.00012 | V | Rich to Lean response rate deterioration level |
| $01 | $8A | Multiply by 0.00012 | V | Lean to rich response rate deterioration level |
| $01 | $90 | Multiply by 0.001 | Second | Rich to Lean delay level |
| $01 | $90 | Multiply by 0.001 | Second | Lean to rich delay level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8A | Multiply by 0.00012 | V | Rich to Lean response rate deterioration level |
| $05 | $8A | Multiply by 0.00012 | V | Lean to rich response rate deterioration level |
| $05 | $90 | Multiply by 0.001 | Second | Rich to Lean delay level |
| $05 | $90 | Multiply by 0.001 | Second | Lean to rich delay level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $06 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles- Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle- Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles- Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle- Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles- Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle- Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles- Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle- Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles- Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle- Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles- Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle- Total |
MISFIRE
LS 460 & LS 460L
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8A | Multiply by 0.00012 | V | Rich to Lean response rate deterioration level |
| $01 | $8A | Multiply by 0.00012 | V | Lean to rich response rate deterioration level |
| $01 | $90 | Multiply by 0.001 | Second | Rich to Lean delay level |
| $01 | $90 | Multiply by 0.001 | Second | Lean to rich delay level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8A | Multiply by 0.00012 | V | Rich to Lean response rate deterioration level |
| $05 | $8A | Multiply by 0.00012 | V | Lean to rich response rate deterioration level |
| $05 | $90 | Multiply by 0.001 | Second | Rich to Lean delay level |
| $05 | $90 | Multiply by 0.001 | Second | Lean to rich delay level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $42 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 1 Sensor 2 |
| $46 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 2 Sensor 2 |
REAR HO2S HEATER
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles- Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle- Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles- Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle- Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles- Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle- Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles- Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle- Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles- Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle- Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles- Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle- Total |
| $A8 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 7: Misfire counts for last ten driving cycles- Total |
| $A8 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 7: Misfire counts for last/current driving cycle- Total |
| $A9 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 8: Misfire counts for last ten driving cycles- Total |
| $A9 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 8: Misfire counts for last/current driving cycle- Total |
MISFIRE
LS 600hL
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel cut |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel cut |
| $06 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
| $3D | $D8 | Multiply by 0.001 | KPa | Test value for canister small leak (P1420) |
| $3D | $D9 | Multiply by 0.001 | KPa | Test value for canister gross leak (P1421) |
| $3D | $DA | Multiply by 0.001 | KPa | Test value for fuel tank small leak (P1422) |
| $3D | $DB | Multiply by 0.001 | KPa | Test value for fuel tank gross leak (P1423) |
| $3D | $DC | Multiply by 0.001 | KPa | Test value for fuel vapor-containment valve close stuck (P2451) |
| $3D | $DD | Multiply by 0.001 | KPa | Test value for fuel vapor-containment valve open stuck (P2450) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $42 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 1 Sensor 2 |
| $46 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 2 Sensor 2 |
REAR HO2S HEATER
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles- Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle- Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles- Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle- Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles- Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle- Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles- Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle- Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles- Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle- Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles- Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle- Total |
| $A8 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 7: Misfire counts for last ten driving cycles- Total |
| $A8 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 7: Misfire counts for last/current driving cycle- Total |
| $A9 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 8: Misfire counts for last ten driving cycles- Total |
| $A9 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 8: Misfire counts for last/current driving cycle- Total |
MISFIRE
LX 570
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel cut |
| $02 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel cut |
| $06 | $8F | Multiply by 0.0003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $42 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 1 Sensor 2 |
| $46 | $91 | Multiply by 0.001 | Ohm | Maximum sensor heater current - Bank 2 Sensor 2 |
REAR HO2S HEATER
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $71 | $E1 | Multiply by 0.01 | G/sec. | AIR amount for AIR insufficient |
| $71 | $E2 | Multiply by 0.01 | KPa | Averaged AIR pressure for AIR pump stuck ON |
| $71 | $E3 | Multiply by 0.01 | KPa | Averaged AIR pressure for AIR pump stuck OFF |
| $71 | $E4 | Multiply by 0.01 | KPa | Test value of AIR control valve ON |
| $71 | $E5 | Multiply by 0.01 | KPa | Test value of AIR control valve OFF |
SECONDARY AIR INJECTION (AIR) - FOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $72 | $E1 | Multiply by 0.01 | G/sec. | AIR amount for AIR insufficient |
| $72 | $E2 | Multiply by 0.01 | KPa | Averaged AIR pressure for AIR pump stuck ON |
| $72 | $E3 | Multiply by 0.01 | KPa | Averaged AIR pressure for AIR pump stuck OFF |
| $72 | $E4 | Multiply by 0.01 | KPa | Test value of AIR control valve ON |
| $72 | $E5 | Multiply by 0.01 | KPa | Test value of AIR control valve OFF |
SECONDARY AIR INJECTION (AIR) - FOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles- Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle- Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles- Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle- Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles- Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle- Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles- Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle- Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles- Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle- Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles- Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle- Total |
| $A8 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 7: Misfire counts for last ten driving cycles- Total |
| $A8 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 7: Misfire counts for last/current driving cycle- Total |
| $A9 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 8: Misfire counts for last ten driving cycles- Total |
| $A9 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 8: Misfire counts for last/current driving cycle- Total |
MISFIRE
RX 350
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $85 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 EXHAUST CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $02 | $8F | Multiply by 0.003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $06 | $8F | Multiply by 0.003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles- Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle- Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles- Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle- Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles- Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle- Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles- Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle- Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles- Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle- Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles- Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle- Total |
MISFIRE
RX 450h
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $31 | $BD | Multiply by 0.01 | KPa | Delta Manifold Absolute Pressure |
EXHAUST GAS RECIRCULATION SYSTEM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $01 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $01 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $02 | $8F | Multiply by 0.003 | G | Maximum oxygen storage capacity |
HO2S BANK 1 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $05 | $91 | Multiply by 0.004 | MA | A/F sensor current |
A/F SENSOR BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
| $06 | $8F | Multiply by 0.003 | G | Maximum oxygen storage capacity |
HO2S BANK 2 SENSOR 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.003 | No dimension | Oxygen storage capacity of catalyst-bank 1 |
CATALYST-BANK 1
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.003 | No dimension | Oxygen storage capacity of catalyst-bank 2 |
CATALYST-BANK 2
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
| $3D | $D8 | Multiply by 0.001 | KPa | Test value for canister small leak (P1420) |
| $3D | $D9 | Multiply by 0.001 | KPa | Test value for canister gross leak (P1421) |
| $3D | $DA | Multiply by 0.001 | KPa | Test value for fuel tank small leak (P1422) |
| $3D | $DB | Multiply by 0.001 | KPa | Test value for fuel tank gross leak (P1423) |
| $3D | $DC | Multiply by 0.001 | KPa | Test value for fuel vapor-containment valve close stuck (P2451) |
| $3D | $DD | Multiply by 0.001 | KPa | Test value for fuel vapor-containment valve open stuck (P2450) |
EVAP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycles-Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles-Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycles- Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycle- Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycles- Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycle- Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycles- Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycle- Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycles- Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycle- Total |
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 5: Misfire counts for last ten driving cycles- Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 5: Misfire counts for last/current driving cycle- Total |
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 6: Misfire counts for last ten driving cycles- Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 6: Misfire counts for last/current driving cycle- Total |
MISFIRE
SC 430
| Monitor ID | Test ID | Scaling | Unit | Description of Test Value |
|---|---|---|---|---|
| $01 | $03 | Multiply by 0.001 | V | Criteria of Lean sensor O2S is Lean when voltage is lower than this value |
| $01 | $04 | Multiply by 0.001 | V | Criteria of Rich sensor O2S is Rich when voltage is higher than this value |
| $01 | $05 | Multiply by 0.001 | Seconds | Rich - Lean switch time |
| $01 | $06 | Multiply by 0.001 | Seconds | Lean - Rich switch time |
| $01 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $01 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $01 | $81 | Multiply by 0.001 | Seconds | Duration while sensor voltage stuck Lean or Rich |
| $01 | $82 | Multiply by 0.001 | Seconds | Time of one cycle of sensor output |
FRONT HEATED OXYGEN SENSOR (BANK 1 SENSOR 1)
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $05 | $03 | Multiply by 0.001 | V | Criteria of Lean sensor O2S is Lean when voltage is lower than this value |
| $05 | $04 | Multiply by 0.001 | V | Criteria of Rich sensor O2S is Rich when voltage is higher than this value |
| $05 | $05 | Multiply by 0.001 | Seconds | Rich - Lean switch time |
| $05 | $06 | Multiply by 0.001 | Seconds | Lean - Rich switch time |
| $05 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $05 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $05 | $81 | Multiply by 0.001 | Seconds | Duration while sensor voltage stuck Lean or Rich |
| $05 | $82 | Multiply by 0.001 | Seconds | Time of one cycle of sensor output |
FRONT HEATED OXYGEN SENSOR (BANK 2 SENSOR 1)
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $02 | $05 | Multiply by 0.001 | Seconds | Rich - Lean switch time |
| $02 | $06 | Multiply by 0.001 | Seconds | Lean - Rich switch time |
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $84 | Multiply by 0.01526 | % | Percentage of time that sensor voltage is lower than 0.05 V |
| $02 | $85 | Multiply by 0.01526 | % | Percentage of time that sensor voltage is higher than 0.7 V |
| $02 | $86 | Multiply by 0.1 | Seconds | Duration that sensor voltage is higher than 0.45 V |
| $02 | $87 | Multiply by 0.01526 | % | Percentage of time that sensor voltage is higher than 0.45 V |
| $02 | $88 | Multiply by 0.1 | Seconds | Cumulative time that sub-feedback compensation factor remained 7% or more |
| $02 | $89 | Multiply by 0.01526 | % | Percentage of time that sub-feedback compensation factor remained 0.05 V or more |
| $02 | $8A | Multiply by 1 | Time | Frequency of sensor switching |
| $02 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
REAR HEATED OXYGEN SENSOR (BANK 1 SENSOR 2)
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $06 | $05 | Multiply by 0.001 | Seconds | Rich - Lean switch time |
| $06 | $06 | Multiply by 0.001 | Seconds | Lean - Rich switch time |
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $84 | Multiply by 0.01526 | % | Percentage of time that sensor voltage is lower than 0.05 V |
| $06 | $85 | Multiply by 0.01526 | % | Percentage of time that sensor voltage is higher than 0.7 V |
| $06 | $86 | Multiply by 0.1 | Seconds | Duration that sensor voltage is higher than 0.45 V |
| $06 | $87 | Multiply by 0.01526 | % | Percentage of time that sensor voltage is higher than 0.45 V |
| $06 | $88 | Multiply by 0.1 | Seconds | Cumulative time that sub-feedback compensation factor remained 7% or more |
| $06 | $89 | Multiply by 0.01526 | % | Percentage of time that sub-feedback compensation factor remained 0.05 V or more |
| $06 | $8A | Multiply by 1 | Time | Frequency of sensor switching |
| $06 | $8B | Multiply by 0.001 | Seconds | 0.35 - 0.2 V sensor switch time |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel-cut |
REAR HEATED OXYGEN SENSOR (BANK 2 SENSOR 2)
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $21 | $A1 | Multiply by 0.0003 | No dimension | Locus length ratio of O2S sensor 1 and sensor 2 |
| $21 | $A2 | Multiply by 0.0003 | No dimension | Voltage area ratio of O2S sensor 1 and sensor 2 |
| $21 | $A3 | Multiply by 0.0003 | No dimension | Locus length ratio of O2S sensor 1 and sensor 2 |
| $21 | $A4 | Multiply by 0.0003 | No dimension | O2S frequency ratio of sensor 2 and sensor 1 |
| $21 | $A5 | Multiply by 0.0003 | No dimension | Locus length ratio of O2S sensor 1 and sensor 2 |
| $21 | $A6 | Multiply by 0.0003 | No dimension | Voltage area ratio of O2S sensor 1 and sensor 2 |
CATALYST - FRONT O2S AND REAR O2S TYPE (BANK 1)
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $22 | $A1 | Multiply by 0.0003 | No dimension | Locus length ratio of O2S sensor 1 and sensor 2 |
| $22 | $A2 | Multiply by 0.0003 | No dimension | Voltage area ratio of O2S sensor 1 and sensor 2 |
| $22 | $A3 | Multiply by 0.0003 | No dimension | Locus length ratio of O2S sensor 1 and sensor 2 |
| $22 | $A4 | Multiply by 0.0003 | No dimension | O2S frequency ratio of sensor 2 and sensor 1 |
| $22 | $A5 | Multiply by 0.0003 | No dimension | Locus length ratio of O2S sensor 1 and sensor 2 |
| $22 | $A6 | Multiply by 0.0003 | No dimension | Voltage area ratio of O2S sensor 1 and sensor 2 |
CATALYST - FRONT O2S AND REAR O2S TYPE (BANK 2)
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $35 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 1 INTAKE CAM
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $36 | $81 | Multiply by 0.01 | Second | Forced movement of oil control valve time |
BANK 2 INTAKE CAM
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.001 | KPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | KPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | KPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | KPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | KPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | KPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | KPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | KPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | KPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | KPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | KPa | Test value for purge flow insufficient (P0441) |
EVAP - KEY-OFF TYPE
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire counts for last ten driving cycles - Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire counts for last driving cycle and current driving cycle - Total |
MISFIRE - ALL CYLINDERS
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire counts for last ten driving cycles - Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire counts for last driving cycle and current driving cycle - Total |
MISFIRE - CYLINDER 1
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire counts for last ten driving cycles - Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire counts for last driving cycle and current driving cycle - Total |
MISFIRE - CYLINDER 2
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire counts for last ten driving cycles - Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire counts for last driving cycle and current driving cycle - Total |
MISFIRE - CYLINDER 3
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire counts for last ten driving cycles - Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire counts for last driving cycle and current driving cycle - Total |
MISFIRE - CYLINDER 4
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A6 | $0B | Multiply by 1 | Time | EWMA misfire counts for last ten driving cycles - Total |
| $A6 | $0C | Multiply by 1 | Time | Misfire counts for last driving cycle and current driving cycle - Total |
MISFIRE - CYLINDER 5
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A7 | $0B | Multiply by 1 | Time | EWMA misfire counts for last ten driving cycles - Total |
| $A7 | $0C | Multiply by 1 | Time | Misfire counts for last driving cycle and current driving cycle - Total |
MISFIRE - CYLINDER 6
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A8 | $0B | Multiply by 1 | Time | EWMA misfire counts for last ten driving cycles - Total |
| $A8 | $0C | Multiply by 1 | Time | Misfire counts for last driving cycle and current driving cycle - Total |
MISFIRE - CYLINDER 7
| MID | TID | Scaling | Unit | Description |
|---|---|---|---|---|
| $A9 | $0B | Multiply by 1 | Time | EWMA misfire counts for last ten driving cycles - Total |
| $A9 | $0C | Multiply by 1 | Time | Misfire counts for last driving cycle and current driving cycle - Total |
MISFIRE - CYLINDER 8