Contents Section: Cooling Fan All sections

Cooling (Service Specifications): Other Lexus GS III рестайлинг

SERVICE DATA

Standard valve opening temperature80 to 84°C (176 to 183°F)
Standard valve lift8.0 mm (0.315 in.) or more at 95°C (203°F)

WATER INLET WITH THERMOSTAT

No. 1 cooling fan motorStandard current5.6 to 11. A at 20°C (68°F)
No. 1 cooling fan motor

COOLING FAN MOTOR

3 - 510 Mohms or higher
3 - 5Below 1 ohms (when battery voltage is applied to terminals 1 and 2)

COOLING FAN RELAY

Standard valve (for brand-new cap)93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm 2 , 13.5 to 17.8 psi)
Minimum standard valve (after using cap)78.5 kPa (0.8 kgf/cm 2 , 11.4 psi)

RADIATOR CAP (STANDARD JUDGMENT CRITERION)