SERVICE DATA
| Item | Specified Condition |
|---|---|
| Standard value (for brand-new cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm 2 , 13.6 to 18 psi) |
| Minimum standard value (for used cap) | 94 kPa (1.0 kgf/cm 2 , 13.6 psi) |
RESERVE TANK CAP (FOR INVERTER)
| Item | Tester Connection | Specified Condition |
|---|---|---|
| IGCT relay Resistance | 3 - 5 | 10 kohms or higher (No auxiliary battery voltage is applied across terminals 1 and 2) |
| 3 - 5 | Below 1 ohms (Auxiliary battery voltage is applied across terminals 1 and 2) |
RELAY
| SMRB Resistance | 4 (SMRB) - 2 (GND) | 19.0 to 35.5 ohms (at -40°C (-40°F) to 80°C (176°F)) |
|---|---|---|
| SMRG Resistance | 1 (SMRG) - 2 (GND) | 19.0 to 35.5 ohms (at -40°C (-40°F) to 80°C (176°F)) |
| SMRP Resistance | 3 (SMRP) - 2 (GND) | 112 to 274 ohms (at -40°C (-40°F) to 80°C (176°F)) |
| Precharge resistor | 28.5 to 31.5 ohms | |
| Electric vehicle fuse | Below 1 ohms |
HYBRID BATTERY JUNCTION BLOCK
| Service plug grip | Always | Below 1 ohms |
SERVICE PLUG GRIP
| EV switch | H72-3 (S) - H72-14 (E) | Below 1 ohms (EV switch being pushed and held) |
|---|---|---|
| 10 kohms or higher (EV switch not operated) | ||
| SPORT mode switch | H72-6 (PWR) - H72-14 (E) | Below 1 ohms (Mode switch being turned and held at SPORT position) |
| 10 kohms or higher (Mode switch not turned) | ||
| ECO mode switch | H72-5 (ECO) - H72-13 (E) | Below 1 ohms (Mode switch being turned and held at ECO position) |
| 10 kohms or higher (Mode switch not turned) | ||
| NORMAL mode switch | H72-4 (NORM) - H72-14 (E) | Below 1 ohms Mode switch being pushed and held at NORMAL position |
| 10 kohms or higher Mode switch not pushed | ||
| Seat heater switch | 3 (RV) - 4 (SW) LH Side | 0.28 to 0.42 kohms (Off) |
| 0.28 to 0.42 kohms (On (Min.)) | ||
| 2.72 to 4.08 kohms (On (Max.)) | ||
| 1 (REL1) - 6 (SW) | 0.28 to 0.42 kohms (Off) | |
| 0.28 to 0.42 kohms (On (Min.)) | ||
| 2.72 to 4.08 kohms (On (Max.)) |
COMBINATION SWITCH ASSEMBLY