Section contents
DiagnostData Academy

Power circuit management

How terminals S, 15, 50 and 75 are switched: an ignition lock with four switches or a start button, the “two out of three” rule for the terminal 15 relay, and starter operation — based on self-study program SSP 611.

DiagnostData AcademyControl units and coding Power circuit management
DiagnostData AcademyControl units and coding Power circuit management

How power supply circuit management works: which unit generates the terminals, why the ignition comes on even if one switch fails, and how the starter is engaged.

4switches in the ignition lock
2 out of 3wires live — and the terminal 15 relay switches on
2starter relays J906 and J907
2microswitches in the E408 start button

Who controls the terminals

without keyless access — J527 · with it — J764

Which control unit manages the power supply circuits — the terminals — depends on the equipment: without keyless access it is the steering column electronics control unit, with it — the steering column lock control unit. (without keyless access — J527 · with it — J764)

ignition lock — 4 switches: S, terminal 15 requests 1 and 2, terminal 50 request

Without keyless access, the ignition lock has four switches: contact S, two terminal fifteen requests and a terminal fifty request. (ignition lock — 4 switches: S, terminal 15 requests 1 and 2, terminal 50 request)

J527: status of terminals 15, 50, 75 and S — via CAN convenience

From them, the steering column control unit determines the status of terminals fifteen, fifty and seventy-five and contact S, and continuously transmits it over the CAN bus. (J527: status of terminals 15, 50, 75 and S — via CAN convenience)

Terminal fifteen: two of three

contact S: key inserted → CAN and separate wire in J519

Contact S closes when the key is inserted; the unit reports this over the bus and via a separate wire to the onboard power supply control unit. (contact S: key inserted → CAN and separate wire in J519)

J519 reads 3 wires: request 1, request 2, contact S

The terminal fifteen relay is switched by the onboard power supply control unit: it reads three wires — the two terminal fifteen requests and contact S. (J519 reads 3 wires: request 1, request 2, contact S)

voltage on 2 of 3 → relay J329 on

If at least two of the three wires carry voltage, the relay switches on — so the ignition comes on even if one switch fails. (voltage on 2 of 3 → relay J329 on)

Terminal fifty

start request to J623 — by wire and via CAN

The engine control unit receives the start request via a separate wire and over the CAN bus. (start request to J623 — by wire and via CAN)

J623 → relay J906, J907 → terminal 50 on the starter · diagnostic wire

The control unit switches both starter relays to ground, the starter receives terminal fifty voltage, and the unit checks via a diagnostic wire that the terminal is actually switched on. (J623 → relay J906, J907 → terminal 50 on the starter · diagnostic wire)

With keyless access

button E408: 2 microswitches → J764

With keyless access, the ignition lock is replaced by a start button with two microswitches — they are read by the steering column lock control unit. (button E408: 2 microswitches → J764)

one fails — no ignition, no start · switching off — once

If one microswitch fails, neither the ignition nor the start can be switched on — the engine can only be switched off with the button once. (one fails — no ignition, no start · switching off — once)

no terminal 75 relay — its status via CAN

There is no longer a separate terminal seventy-five relay: the control units receive its status over the CAN bus. (no terminal 75 relay — its status via CAN)

Summary

  • Which control unit manages the power supply circuits — the terminals — depends on the equipment: without keyless access it is the steering column electronics control unit, with it — the steering column lock control unit.
  • The terminal fifteen relay is switched by the onboard power supply control unit: it reads three wires — the two terminal fifteen requests and contact S.
  • If at least two of the three wires carry voltage, the relay switches on — so the ignition comes on even if one switch fails.
  • The control unit switches both starter relays to ground, the starter receives terminal fifty voltage, and the unit checks via a diagnostic wire that the terminal is actually switched on.
  • If one microswitch fails, neither the ignition nor the start can be switched on — the engine can only be switched off with the button once.

Next episode: interior lighting.

Section contents