AIR CONDITIONING (A/C) SYSTEM RECOVERY, EVACUATION AND CHARGING
- Refrigerant recovery and recycle.
- Remove the access cover.
- Remove the dust covers from the high and low pressure connections.
- Connect the high and low pressure lines to the appropriate connections.
- Open the valves on the connections.
- Turn the valves on the station to the correct positions.
- Allow the system to recover the refrigerant from the system.
- Close the valves on the refrigerant station.
- Close the valves on the connections.
- Disconnect the high and low pressure connections.
- Install the dust covers to the connectors.
- Evacuation.
- Remove the dust covers from the high and low pressure connections.
- Connect the high and low pressure lines to the appropriate connections.
- Open the valves on the connections.
- Allow the station to evacuate the A/C system.
- Recharging
- Close the valves on the refrigerant station.
- Close the valves on the connections.
- Disconnect the high and low pressure connections.
- Install the dust covers to the connectors. Torque: 6 Nm
- Install the access cover.