Contents Wiring diagrams Section: BCM (Body Control Module) All sections

PANIC Kia Sedona II facelift

PANIC

  1. If RKE PANIC signal is received, Siren output and hazard lamp operate for 27 seconds and the system return to the previous state as soon as the PANIC function finishes.
  2. The PANIC function will be stopped if any RKE signal is received during PANIC activation.
  3. If Key reminder switch is ON during PANIC function is operating, PANIC is stopped immediately.
  4. If the system goes to ALARM mode during PANIC function is operating, PANIC is stopped immediately and then ALARM function should be activated.
  5. During ALARM state; If RKE PANIC signal is received, ALARM mode is maintained and PANIC function should be ignored. ALARM has higher priority than PANIC function.
  6. During AFTER_ALARM state; If RKE PANIC signal is received, AFTR_ALARM mode is maintained and PANIC function should be activated.