Removal
- Disconnect the vapor hose (A).
- Remove the PCV valve (B).
Scheme 9
Installation
- Installation is reverse of removal.
PCV Valve installation
7.8 ~ 11.8 N.m (0.8 ~ 1.2 kgf.m, 5.8 ~ 8.7 lb-ft)
PCV Valve installation
7.8 ~ 11.8 N.m (0.8 ~ 1.2 kgf.m, 5.8 ~ 8.7 lb-ft)