SPECIFICATIONS
| Description | Specification |
|---|---|
| Air conditioning (A/C) refrigerant | HFC 134a |
| A/C compressor oil | ND-OIL8 |
LUBRICANTS, FLUIDS, SEALERS AND ADHESIVES
| Description | Grammes |
|---|---|
| A/C refrigerant | 750 |
CAPACITIES
| Item | Milliliters |
|---|---|
| Condenser core and desiccant bag | Add 33 |
| Evaporator | Add 46 |
| A/C compressor | 1. Drain old A/C compressor. With drain plug removed and ports uncapped, rotate shaft to remove oil and measure the amount of oil captured. 2. Drain new A/C compressor into a clean vessel. With drain plug removed and ports uncapped, rotate shaft to remove oil. Then add back a quantity of the new oil that is identical to the quantity of oil removed from the old A/C compressor. However, if this quantity is less than 30ml, then make it up to 30ml. |
| A/C lines - If air conditioning has been operational. | Add 10 per line |
REFRIGERANT OIL ADDING CAPACITIES
Note. Rotate the A/C compressor shaft at least 6 to 8 turns when draining the refrigerant oil.