SENSOR RANGE CHARTS

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.

Note. Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.

Temperature - °F (°C)Ohms
68 (20)2100-2900
122 (50)680-1000
176 (80)300-330
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

COOLANT TEMPERATURE SENSOR RESISTANCE (1)

Temperature - °F (°C)Ohms
212 (100)76,770-93,830
(1) Heat sensor in water and measure resistance across sensor terminals.
(1)Heat sensor in water and measure resistance across sensor terminals.

EGR TEMPERATURE SENSOR RESISTANCE (1)

Temperature - °F (°C)Ohms
68 (20)2100-2900
122 (50)680-1000
176 (80)300-330
(1) Measure resistance between sensor terminals at pressure regulator.
(1)Measure resistance between sensor terminals at pressure regulator.

FUEL TEMPERATURE SENSOR RESISTANCE (1)

ConditionVolts
Lean0-0.3
Rich0.6-1.0
(1) Measure voltage between oxygen sensor terminal and ground, voltage should continuously change. Measure heater resistance between terminals "A" and "C" at sensor. Resistance should be 3-1000 ohms.
(1)Measure voltage between oxygen sensor terminal and ground, voltage should continuously change. Measure heater resistance between terminals "A" and "C" at sensor. Resistance should be 3-1000 ohms.

HEATED OXYGEN SENSOR VOLTAGE (1)

PositionReading
Closed ThrottleContinuity
Open ThrottleNo Continuity
(1) Check continuity between terminals No. 2 and 3 at sensor. (Scheme 1)
(1)Check continuity between terminals No. 2 and 3 at sensor. (Scheme 1)

CLOSED THROTTLE POSITION SWITCH CONTINUITY (1)

PositionOhms
Closed Throttle1700
Partially Open1700-10,500
Wide Open Throttle10,500
(1) Measure resistance between terminals No. 4 and 5 at sensor. (Scheme 1)
(1)Measure resistance between terminals No. 4 and 5 at sensor. (Scheme 1)

THROTTLE POSITION SENSOR RESISTANCE (1)

ApplicationTerminal NoVolts
J30"b"1.0-1.4
(1) Measure voltage between ground and indicated airflow meter terminal with engine idling at normal operating temperature.
(1)Measure voltage between ground and indicated airflow meter terminal with engine idling at normal operating temperature.

MASS AIRFLOW SENSOR VOLTAGE (LOW RPM) (1)

ApplicationTerminal NoVolts
J30"b"1.4-1.9
(1) Measure voltage between ground and indicated airflow meter terminal with engine running at 2000 RPM at normal operating temperature.
(1)Measure voltage between ground and indicated airflow meter terminal with engine running at 2000 RPM at normal operating temperature.

MASS AIRFLOW SENSOR VOLTAGE (HIGH RPM) (1)

Scheme 1

Scheme 1