Contents Section: Heater & Air Conditioning Control System -- Convertible All sections

SUNLOAD INPUT PROCESS Infiniti G37 IV рестайлинг

SUNLOAD INPUT PROCESS

The unified meter and A/C amp. also equips a processing circuit which averages the variations in detected sunload over a period of time. This prevents drastic swings in the air temperature control system operation due to small or quick variations in detected sunload.

For example, consider driving along a road bordered by an occasional group of large trees. The sunload detected by the sunload sensor varies whenever the trees obstruct the sunlight. The processing circuit averages the detected sunload over a period of time, so that the (insignificant) effect of the trees momentarily obstructing the sunlight does not cause any change in the air temperature control system operation. On the other hand, shortly after entering a long tunnel, the system recognizes the change in sunload, and the system reacts accordingly.

  1. PERFORM SELF-DIAGNOSIS Perform self-diagnosis function STEP-2. Refer to " «DIAGNOSIS DESCRIPTION»(ref-336714-S13742628812009072900000) ". 25 or -25 is displayed. YES: Go to Diagnosis Procedure. Refer to " «DIAGNOSIS PROCEDURE»(ref-336714-S13431394332009072900000) ". NO: INSPECTION END