Contents Section: Automatic Air Conditioner All sections

Insufficient Cooling Infiniti FX35 I рестайлинг

Automatic Air Conditioner 3 illustrations

Insufficient Cooling

SYMPTOM: Insufficient cooling

Scheme 192

Scheme 192: INSPECTION FLOW
*1. FUNCTION CONFIRMATION PROCEDURE , see No. 4 to 6.
*2. AIR MIX DOOR MOTOR CIRCUIT
*3. TEST READING
*4. AUXILIARY MECHANISM: TEMPERATURE SETTING TRIMMER
*5. FUNCTION CONFIRMATION PROCEDURE , No. see 13.
*6. LAN SYSTEM CIRCUIT
*7. BLOWER MOTOR CIRCUIT
*8. MAGNET CLUTCH CIRCUIT
*9. PERFORMANCE TEST DIAGNOSIS
*10. OPERATIONAL CHECK
*11. CONTAMINATED REFRIGERANT
*12. CHECKING DRIVE BELTS - VQ35DE or CHECKING DRIVE BELTS - VK45DE
*13. SYSTEM DESCRIPTION - VQ35DE or SYSTEM DESCRIPTION - VK45DE

INSUFFICIENT COOLING INSPECTION FLOW CHART REFERENCES

Scheme 193

Scheme 193: PERFORMANCE TEST DIAGNOSIS
*1. PERFORMANCE CHART
*2. PERFORMANCE CHART
*3. TROUBLE DIAGNOSIS FOR UNUSUAL PRESSURE
*4. AIR MIX DOOR MOTOR CIRCUIT

INSUFFICIENT COOLING DIAGNOSIS FLOW CHART REFERENCES (1 OF 2)

Scheme 194

Scheme 194
*1. REMOVAL AND INSTALLATION OF COMPRESSOR CLUTCH
*2. BLOWER MOTOR CIRCUIT
*3. CHECKING DRIVE BELTS - VQ35DE or CHECKING DRIVE BELTS - VK45DE

INSUFFICIENT COOLING DIAGNOSIS FLOW CHART REFERENCES (2 OF 2)