Contents Wiring diagrams Section: Automatic Transaxle System (F4A42) All sections

ACTUATORS Hyundai Sonata V facelift

ACTUATORS

Solenoid Valve for Pressure Control

  1. Sensor type : Normal open 3-way
  2. Operating temperature : -30°C~130°C (-22°F~266°F)
  3. Frequency

LR, 2ND, UD, OD : 61.27Hz (at the ATF temp, above

20°C (-4°F))

DCC : 30.64HZ

  1. Internal resistance : 3.0 ± 0.5 ohms (LR, 2ND, UD, OD, TCC) 4.35 ± 0.5 ohms (VFS)
  2. Surge voltage : 56 V (Except VFS)

Scheme 274

Scheme 274

Scheme 275

Scheme 275: LOCATION