Specification
| Item | Standard value |
|---|---|
| Rate voltage | DC 12V |
| Operating voltage range | DC9 ~16V |
| Operating temperature range | 30 ~ +65°C (-22 ~ 149°F) |
| Direction display | 8 |
| Renewal time | 2 sec. |
COMPASS MIRROR SPECIFICATION
| ITEM | DESCRIPTION | REMARK |
|---|---|---|
| Rated Voltage | DC 12V | Testing Voltage: 12.8V |
| Operating Voltage | 9 ~ 18V | Should be operation at limit rage |
| Operating Temperature | 30 ~ 85°C (-22 ~ 185°F) | |
| Storage Temperature | 40 ~ 105°C (40 ~ 221°F) | |
| Operating Humidity | 95% | |
| Operating Current | 23 ~ 100mA | |
| Low power Mode | 4 ~ 16mA | |
| Reduce power Mode | 10 ~ 25mA | |
| Insulation Resistant | 100Mohms (500VM) | The case is exclude in EARTH |
| Dark current | 0.3mA MAX |
HOMELINK SPECIFICATION
Learn & Transmit Specification
| Signal | Specification | Remark | |
|---|---|---|---|
| Learn RF Signal | Learning Frequency | 288-390 MHz | |
| Learning Range | 0-1 m | Between H/L & Drive seat | |
| Transmit RF Signal | Transmission Frequency | 288-390 MHz | |
| Transmission Range | 13m MIN | ||
| Output Power | 75.6dBμV/m MAX | Do as the FCC | |
LEARN & TRANSMIT SPECIFICATION
In case of OT (Original Transmitter) range < 80% of Transmission SPEC. It should be apply to transmission range for 80% of OT.
- Follow the OT or OR (Original Receiver) about reception & transmission frequency.
- Transmission Range means the distance from which the receiving device RF signal from HomeLink)
- Reception Range means the distance within which the HomeLink can be trained with RF signal from OT.