Home/Honda/Accord/Honda Accord IV (1989-1993)/Repair manual/Sensor Range Charts/Engine Controls - Sensor Operating Range Charts
Contents Section: Sensor Range Charts All sections

Engine Controls - Sensor Operating Range Charts Honda Accord IV

INTRODUCTION

Sensor operating range information can help determine if a sensor is out of calibration. Although an out-of-calibration sensor may not set a trouble code, it may cause driveability problems.

BARO Pressure - In. HgVolts
02.8-3.0
52.3-2.5
101.8-2.0
151.3-1.5
20.8-1.0
25.3-.5
(1) Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS article in the ENGINE PERFORMANCE Section.
(1)Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS article in the ENGINE PERFORMANCE Section.

ATMOSPHERIC PRESSURE SENSOR VOLTAGE TEST (1)

Temperature - °F (°C)Ohms
4 (-20)15,000-18,000
68 (20)1000-4000
176 (80)200-400
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

COOLANT TEMP (TW) SENSOR RESISTANCE TEST (1)

Temperature - °F (°C)Ohms
4 (-20)15,000-18,000
68 (20)1000-4000
176 (80)200-400
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

INTAKE AIR TEMP (TA) SENSOR RESISTANCE TEST (1)

Vacuum Applied - In. Hg.Volts
02.8-3.0
52.3-2.5
101.8-2.0
151.3-1.5
20.8-1.0
25.3-.5
(1) Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS article in the ENGINE PERFORMANCE Section.
(1)Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS article in the ENGINE PERFORMANCE Section.

MAP SENSOR VOLTAGE TEST (1)

PositionVolts (Approx.)
Accord & Prelude
Fully Closed1.2
Fully Open4.0
Civic & CRX
Fully Closed1.0
Fully OpenN/A
(1) Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS article in the ENGINE PERFORMANCE Section. Voltage should increase smoothly as vacuum is applied.
(1)Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS article in the ENGINE PERFORMANCE Section. Voltage should increase smoothly as vacuum is applied.

EGR LIFT SENSOR VOLTAGE TEST (1)

ConditionVolts
LeanLess Than 0.4
RichGreater Than 0.6
(1) Measure voltage between ground and O2 sensor terminal using a high-impedance DVOM.
(1)Measure voltage between ground and O2 sensor terminal using a high-impedance DVOM.

OXYGEN SENSOR VOLTAGE TEST (1)

Condition(1) Volts
Throttle Valve
Fully Closed.5
Wide Open4.5
(1) Voltage change from fully closed to wide open should be smooth.
(1)Voltage change from fully closed to wide open should be smooth.

THROTTLE ANGLE (POSITION) SENSOR SPECIFICATIONS

ApplicationVolts
All Models (1)(2) 0-5
(1) Backprobe terminals at sensor. (2) Pulses between 0 and 5 volts with sensor turning.
(1)Backprobe terminals at sensor.
(2)Pulses between 0 and 5 volts with sensor turning.

VEHICLE SPEED SENSOR VOLTAGE TEST

See also:
WIRING DIAGRAMS