Contents Section: Cooling System (mechanical) All sections

Cooling System Specifications GMC Value Van P2500

THERMOSTAT

All models use a thermostat that starts to open at 195°F (91°C), and is fully open at 222°F (106°C).

PRESSURE CAP

On "P" Series Motor Homes and some "G" Series Vans with the VIN J 6.2L diesel engine, a de-aeration tank is used instead of a coolant recovery tank.

The de-aeration tank uses a 9 psi (.6 kg/cm 2 ) pressure cap. All other models use a 15 psi (1.0 kg/cm 2 ) pressure cap which should be tested at 14-17 psi (.9-1.2 kg/cm 2 ).

WATER PUMP

Water pump is serviced only as an assembly.

MAINTENANCE

Inspect cooling system every 12 months or 15,000 miles. Drain and flush cooling system every 24 months or 30,000 miles. Maintain coolant level with 50% mixture of ethylene glycol based anti-freeze and low mineral content water in all seasons.

ApplicationQuarts (L)
2.5L
Astro/Safari(1) 10.0 (9.5)
S10/1511.6 (11.0)
2.8L10.5 (10.0)
4.3L
Astro/Safari(1) 13.5 (12.8)
"C" & "K" Series10.9 (10.3)
"G" Series(1) 11.1 (10.5)
4.8L
"C" & "K" Series
With Air Conditioning16.0 (15.1)
Without Air Conditioning15.5 (14.7)
"P" Series13.8 (13.1)
5.0L & 5.7L
"C" & "K" Series
With Air Conditioning(1) 18.0 (17.0)
Without Air Conditioning(1) 17.5 (16.6)
"G" Series(1) 17.0 (16.1)
"P" Series15.5 (14.7)
6.2L Diesel
"C" & "K" Series(1) 25.0 (23.7)
"G" Series
VIN C(1) 24.0 (22.7)
VIN J(1) 25.6 (24.2)
"P" Series
Motor Home24.7 (23.4)
All Except Motor Home25.0 (23.7)
7.4L
"C" & "K" Series
With Air Conditioning(1) 24.5 (23.2)
Without Air Conditioning(1) 23.0 (21.8)
"P" Series22.5 (21.3)
(1) On Astro/Safari, "C" and "K" Series Blazer and Suburban, and "G" Series Van models, add 2.85 qts. (2.7L) for auxiliary rear heater.
(1)On Astro/Safari, "C" and "K" Series Blazer and Suburban, and "G" Series Van models, add 2.85 qts. (2.7L) for auxiliary rear heater.

COOLANT CAPACITY