IAC Valve Reset Procedure
- Turn ON the ignition for 20 seconds.
- Turn OFF the ignition for 10 seconds.
- Start the engine.
- Check for the proper idle speed.
Fuel Tank Draining Procedure
| CAUTION | Gasoline or gasoline vapors are highly flammable. A fire could occur if an ignition source is present. Never drain or store gasoline or diesel fuel in an open container, due to the possibility of fire or explosion. Have a dry chemical (Class B) fire extinguisher nearby. |
- Disconnect the negative battery cable.
- Use a hand operated pump device in order to remove the fuel through the fuel filler pipe.