Engine Controls - Sensor Operating Range Charts GMC Jimmy Typhoon

INTRODUCTION

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it will cause driveability problems.

Note. Perform all voltage tests with a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance, unless stated otherwise in testing procedures.

Temperature - °F (°C)Ohms
212 (100)177
158 (70)467
100 (38)1800
68 (20)3520
23 (-5)12,300
0 (-18)25,000
40 (-40)100,700
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

COOLANT TEMPERATURE RESISTANCE VALUES (1)

Temperature - °F (°C)Ohms
210 (100)185
160 (70)450
100 (38)1800
70 (20)3400
40 (4)7500
20 (-7)13,500
0 (-18)25,000
40 (-40)100,700
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

MANIFOLD AIR TEMPERATURE (MAT) SENSOR RESISTANCE VALUES (1)

Altitude (Ft.)Volts
Below 10003.8-5.5
1000-20003.6-5.3
2000-30003.5-5.1
3000-40003.3-5.0
4000-50003.2-4.8
5000-60003.0-4.6
6000-70002.9-4.5
7000-80002.8-4.3
8000-90002.6-4.2
9000-10,0002.5-4.0
(1) Measured at sensor, or as seen on Scan tester.
(1)Measured at sensor, or as seen on Scan tester.

MAP SENSOR VOLTAGE RANGE (1)

ConditionVolts
Lean.1
Rich.9
(1) Measure voltage between O2 sensor ground and signal terminals at ECM.
(1)Measure voltage between O2 sensor ground and signal terminals at ECM.

OXYGEN SENSOR VOLTAGE TEST (1)