Circuit/System Description
The body control module (BCM) controls the horn relay by grounding the control circuit of the horn relay coil energizing the relay. When the horn relay is energized, the horn relay contacts close applying voltage through the horn fuse and the horn control circuit to the horns.
Battery positive voltage is applied at all times to the horn relay coil and the horn relay switch. Pressing the horn switch applies ground through the switch contacts and the horn relay control circuit to the coil side of the relay, energizing the relay. Battery voltage is then applied through the switch side of the relay, the horn fuse and the horn control circuit to the horns. The body control module (BCM) may also apply ground to the horn relay control circuit as described above. The horns sound as long as ground is applied to the horn relay control circuit.
System Description
The horn system consists of the following components
- HORN fuse
- Horn relay
- Horn switch
- Horn assembly
- Body control module (BCM)
System Operation
The vehicle horn system is activated under the following conditions
- When the horn switch is depressed
- The BCM commands the horns ON under any of the following conditions: When the content theft deterrent system detects a vehicle intrusion-For further information, refer to «Theft Systems Description and Operation»(ref-610088-S19145342442014042100000) . When the panic button is depressed on the remote control door lock transmitter-For further information, refer to «Keyless Entry System Description and Operation»(ref-610064-S30722733932014042100000) . When the keyless entry system is used to lock the vehicle, a horn chirp may sound to notify the driver that the vehicle has been locked. The notification feature may be enabled or disabled through personalization. For further information, refer to «Keyless Entry System Description and Operation»(ref-610064-S30722733932014042100000) . When the OnStar® system is used to sound the horns if equipped-For further information, refer to «OnStar Description and Operation»(ref-610055-S34609759942014042100000) .
Circuit Operation
Battery positive voltage is applied at all times to the horn relay coil and the horn relay switch. Pressing either of the horn switches applies ground to the horn relay control circuit. The BCM may also apply ground to the horn relay control circuit as described above. When the horn relay control circuit is grounded, the horn relay is energized and battery positive voltage is applied to the horns through the horn control circuit. The horns sound as long as ground is applied to the horn relay control circuit.