Home/Ford/Taurus/Ford Taurus V (2007-2009)/Repair manual/Charging System/Charging System - General Information: Other
Contents Wiring diagrams Section: Charging System All sections

Charging System - General Information: Other Ford Taurus V

Charging System 2 illustrations ~192 words

Battery

The battery is a 12V DC source connected in a negative ground system. The battery case is sealed with 2 vent holes to release gases. The battery has 3 major functions

  1. Engine cranking power source
  2. Voltage stabilizer for the electrical system
  3. Temporary power source when electrical loads exceed the generator output current

Special Tools Illustration Tool Name Tool Number 73III Automotive Meter 105-R0057 or equivalent Flex Probe Kit 105-R025B SABRE Premium Battery and Electrical System Tester 010-00736 or equivalent Vehicle Communication Module (VCM) and Integrated Diagnostic System (IDS) software with appropriate hardware, or equivalent scan tool

Scheme 9

Scheme 9: Charging System

Scheme 10

Scheme 10

Pinpoint Tests

CAUTIONElectronic modules are sensitive to electrostatic discharge. If exposed to these charges, damage may result.

Refer to Inspection and Verification, the DTC Chart and the Symptom Chart for direction to the appropriate pinpoint test.

Generator On-Vehicle Tests

CAUTIONTo prevent damage to the generator, do not make the jumper wire connections except as directed.
CAUTIONDo not allow any metal object to come in contact with the housing and the internal diode cooling fins with the key on or off. A short circuit may result and burn out the diodes.

Note. Battery posts and cable clamps must be clean and tight for accurate meter indications.

Note. Refer to the battery tester manual for complete directions for testing the charging system.

  1. Turn off all lamps and electrical components.
  2. Place the transmission in NEUTRAL and apply the parking brake.
  3. Carry out the Load Test and No-Load Test according to the following component tests