Home/Ford/Focus/Ford Focus III (2011-2015)/Repair manual/Manual HVAC System/Climate Control System - General Information - Except Elect…
Contents Wiring diagrams Section: Manual HVAC System All sections

Climate Control System - General Information - Except Electric: Specifications Ford Focus III

Specifications

Specifications
Motorcraft® PAG Refrigerant Compressor Oil YN-12-DWSH-M1C231-B
Motorcraft® R-134a Refrigerant YN-19 (US); CYN-16-R (Canada)WSH-M17B19-A
Motorcraft® A/C System Flushing Solvent YN-23
Motorcraft® A/C Cooling Coil Coating YN-29

LUBRICANTS, FLUIDS, SEALERS AND ADHESIVES

Motorcraft® PAG Refrigerant Compressor Oil YN-12-D4.9 fl oz (145 ml)
Motorcraft® R-134a Refrigerant YN-19 (US); CYN-16-R (Canada)21.2 fl oz (0.60 kg)

CAPACITIES

Polyalkylene Glycol (PAG) Oil Amount fl oz (ml)Method of Adding
After installing the A/C Compressor.Service compressor already contains full system charge of oil. No oil matching is required.
After installing the receiver/drier cartridge.1 fl oz (30 ml) plus the amount collected during refrigerant recovery.Inject to low-side service port during system charging.
After installing the evaporator core, and the receiver/drier cartridge.1 fl oz (30 ml) plus the amount collected during refrigerant recovery.Add directly to inlet port or inject to low-side service port during system charging.
After installing the condenser core.2 fl oz (60 ml)Add directly to inlet port or inject to low-side service port during system charging.
After installing/reassembling the thermostatic expansion valve.1 fl oz (30 ml) plus the amount collected during refrigerant recovery.Inject to low-side service port during system charging.
After installing a refrigerant Hose/Line.2 fl oz (60 ml) plus the amount collected during refrigerant recovery (1) .Inject to low-side service port during system charging.
After an O-ring Leak Repair.1 fl oz (30 ml) plus the amount collected during refrigerant recovery (2) .Inject to low-side service port during system charging.
After a service port leak repair.Amount collected during refrigerant recovery.Inject to low-side service port during system charging.
(1) If an excessive amount of PAG oil is lost due to a hose rupture/separation or other damage, the total system PAG oil capacity must be added.
(2) The amount specified may be used for one or multiple O-ring leak repairs. Do not multiply the PAG oil amount by the number of O-ring leaks being repaired.
(1)If an excessive amount of PAG oil is lost due to a hose rupture/separation or other damage, the total system PAG oil capacity must be added.
(2)The amount specified may be used for one or multiple O-ring leak repairs. Do not multiply the PAG oil amount by the number of O-ring leaks being repaired.

REFRIGERANT OIL ADDING (WHEN NEW COMPONENTS ARE INSTALLED)