INTRODUCTION
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems. Refer to SYSTEM APPLICATION table to determine correct engine control system.
| Application | System |
| 1.8L & 2.2L | EEC |
| 5.8L | MCU |
| All Others | EEC-IV |
Note. Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
ECT SENSOR
| Temperature °F (°C) | Ohms |
| 68 (20) | 2200-2700 |
| 104 (40) | 1000-1300 |
| 140 (60) | 500-650 |
| 176 (80) | 290-350 |
EGR VALVE POSITION (EVP) SENSOR
| Percentage of EGR | Volts |
| 0 | 0.40-0.83 |
| 10 | 0.75-1.18 |
| 20 | 1.10-1.52 |
| 30 | 1.45-1.87 |
| 40 | 1.80-2.22 |
| 50 | 2.15-2.57 |
| 60 | 2.50-2.91 |
| 70 | 2.85-3.26 |
| 80 | 3.20-3.61 |
| 90 | 3.55-3.95 |
| 100 | 3.90-4.30 |
EXHAUST GAS OXYGEN (EGO) SENSOR
| Condition | (1) Voltage |
| Increasing Engine Speed | Increases |
| Decreasing Engine Speed | Decreases |
| Engine At Idle | 0.2-0.8 |
| (1) Measure between oxygen sensor and ground. |
| (1) | Measure between oxygen sensor and ground. |
VAF & VAT SENSORS
| Door Position | (1) Volts |
| Fully Closed | 3.90 |
| 1/8 Open | 3.24 |
| 1/4 Open | 5.60 |
| 3/8 Open | 5.62 |
| 1/2 Open | 5.83 |
| 5/8 Open | 6.02 |
| 3/4 Open | 6.57 |
| 7/8 Open | 7.46 |
| Fully Open | 7.87 |
| (1) Voltage may vary by 15 percent. |
| (1) | Voltage may vary by 15 percent. |
Note. If using hot air gun to heat sensor, avoid overheating plastic or rubber components.
| Temperature °F (°C) | (1) Volts |
| 20 (-6) | 3.64 |
| 30 (-1) | 3.36 |
| 40 (4) | 3.05 |
| 44 (7) | 2.79 |
| 50 (10) | 2.29 |
| 60 (16) | 2.61 |
| 70 (21) | 2.35 |
| 80 (27) | 2.05 |
| 90 (32) | 1.76 |
| 100 (38) | 1.57 |
| (1) Voltage may vary by 15 percent. |
| (1) | Voltage may vary by 15 percent. |
| Temperature °F (°C) | (1) Ohms |
| 4 (-20) | 15,000 |
| 32 (0) | 5210 |
| 68 (20) | 2500 |
| 104 (40) | 1100 |
| 140 (60) | 600 |
| 176 (80) | 300 |
| (1) Resistance may vary by 15 percent. |
| (1) | Resistance may vary by 15 percent. |
THROTTLE POSITION SENSOR (TPS)
| Throttle Position | (1) Ohms | (1) Volts |
| 1/8 Open | .998 | .989 |
| 1/4 Open | 1.104 | 1.60 |
| 3/8 Open | 1.278 | 2.37 |
| 1/2 Open | 1.462 | 2.74 |
| 5/8 Open | 1.480 | 3.15 |
| 3/4 Open | 1.459 | 3.43 |
| 7/8 Open | 1.144 | 3.60 |
| Full Open | 1.072 | 4.02 |
| (1) Values may vary by 15 percent. |
| (1) | Values may vary by 15 percent. |
ACT & ECT SENSORS
| Temperature F (°C) | (1) Volts | (1) Ohms |
| 50 (10) | 3.51 | 58,700 |
| 68 (20) | 3.07 | 37,300 |
| 86 (30) | 2.60 | 24,200 |
| 104 (40) | 2.13 | 16,150 |
| 122 (50) | 1.70 | 10,970 |
| 140 (60) | 1.33 | 7700 |
| 158 (70) | 1.33 | 7700 |
| 176 (80) | .78 | 3840 |
| 194 (90) | .60 | 2800 |
| 212 (100) | .46 | 2007 |
| (1) Values may vary by 15 percent. |
| (1) | Values may vary by 15 percent. |
ACT & ECT SENSORS SPECIFICATIONS
CYLINDER IDENTIFICATION (CID) SENSOR
| Application | Ohms |
| All Models (1) | 300-7000 |
| (1) On 1.9L engines, CID sensor is located in crankshaft position sensor. |
| (1) | On 1.9L engines, CID sensor is located in crankshaft position sensor. |
| Percentage of EGR | (1) Volts |
| 0 | 0.40 |
| 10 | 0.75 |
| 20 | 1.10 |
| 30 | 1.45 |
| 40 | 1.80 |
| 50 | 2.15 |
| 60 | 2.50 |
| 70 | 2.85 |
| 80 | 3.20 |
| 90 | 3.55 |
| 100 | 3.90 |
| (1) Voltage may vary by 15 percent. |
| (1) | Voltage may vary by 15 percent. |
| Condition | (1) Voltage |
| Increasing Engine Speed | Increases |
| Decreasing Engine Speed | Decreases |
| Engine At Idle | 0.2-0.8 |
| (1) Measure between oxygen sensor and ground. |
| (1) | Measure between oxygen sensor and ground. |
MASS AIRFLOW (MAF) SENSOR
| Engine Condition (1) | (2) Voltage |
| Idle | .6 |
| 20 MPH | 1.1 |
| 40 MPH | 1.7 |
| 60 MPH | 2.1 |
| (1) Engine at normal operating temperature. (2) Voltage may vary depending on vehicle load and temperature. |
| (1) | Engine at normal operating temperature. |
| (2) | Voltage may vary depending on vehicle load and temperature. |
MAF SENSOR DATA SPECIFICATIONS
MANIFOLD ABSOLUTE PRESSURE (MAP) SENSOR
| Manifold Vacuum In. Hg | (1) Frequency Hz |
| 0 | 159 |
| 3 | 150 |
| 6 | 141 |
| 9 | 133 |
| 12 | 125 |
| 15 | 117 |
| 18 | 109 |
| 21 | 102 |
| 24 | 95 |
| 27 | 88 |
| 30 | 80 |
| (1) Frequency value may vary by 15 percent. |
| (1) | Frequency value may vary by 15 percent. |
MAP SENSOR SPECIFICATIONS
| Elevation (Feet) | Volts |
| 0 | 1.55-1.63 |
| 1000 | 1.52-1.60 |
| 2000 | 1.49-1.57 |
| 3000 | 1.46-1.54 |
| 4000 | 1.43-1.51 |
| 5000 | 1.40-1.48 |
| 6000 | 1.37-1.45 |
| 7000 | 1.35-1.43 |
MAP SENSOR VOLTAGE OUTPUT
| Barometric Pressure In. Hg | (1) Frequency Hz |
| 17.1 | 122.4 |
| 18.3 | 125.5 |
| 19.5 | 128.7 |
| 20.7 | 131.9 |
| 21.8 | 135.1 |
| 23.0 | 138.3 |
| 24.2 | 141.8 |
| 25.4 | 145.4 |
| 26.6 | 148.9 |
| 27.7 | 152.5 |
| 28.9 | 156.1 |
| 30.1 | 159.6 |
| 31.0 | 162.4 |
| (1) Frequency value may vary by 15 percent. |
| (1) | Frequency value may vary by 15 percent. |
MAP/BP SENSOR SPECIFICATIONS
PRESSURE FEEDBACK EGR (PFE) SENSORS
| Pressure (psi) | (1) Voltage |
| 1.82 | 4.75 |
| 1.36 | 4.38 |
| 0.91 | 4.00 |
| 0.46 | 3.63 |
| 0.0 | 3.25 |
| 2.47 | 1.22 |
| 3.63 | 0.25 |
| (1) Voltage may vary by 15 percent. |
| (1) | Voltage may vary by 15 percent. |
PFE SENSOR SPECIFICATIONS
DELTA PRESSURE FEEDBACK EGR (DPFE)
| Pressure (psi) | (1) Voltage |
| 4.34 | 4.56 |
| 3.25 | 3.54 |
| 2.17 | 2.51 |
| 1.08 | 1.48 |
| 0 | 0.45 |
| (1) Voltage may vary by 15 percent. |
| (1) | Voltage may vary by 15 percent. |
DPFE SENSOR SPECIFICATIONS
MANUAL LEVER POSITION (MLP) SENSOR
| Position | (1) Voltage | (1) Ohms |
| P | 4.41 | 4160 |
| R | 3.60 | 1440 |
| N | 2.83 | 2733 |
| D | 2.09 | 401 |
| 1 | .68 | 81 |
| (1) Value may vary by 15 percent. |
| (1) | Value may vary by 15 percent. |
MLP SENSOR SPECIFICATIONS
| Throttle Angle | (1) Volts |
| 0° | 0.50 |
| 10° | 0.97 |
| 20° | 1.44 |
| 30° | 1.90 |
| 40° | 2.37 |
| 50° | 2.84 |
| 60° | 3.31 |
| 70° | 3.78 |
| 80° | 4.24 |
| (1) Voltage may vary by 15 percent. |
| (1) | Voltage may vary by 15 percent. |
TRANSMISSION OIL TEMPERATURE (TOT) SENSOR
| Temperature °F (°C) | (1) Volts | (1) Ohms |
| 32 (0) | 3.88 | 96,255 |
| 41 (5) | 3.71 | 75,201 |
| 50 (10) | 3.53 | 59,175 |
| 59 (15) | 3.32 | 46,883 |
| 68 (20) | 3.10 | 37,387 |
| 77 (25) | 2.86 | 30,000 |
| 86 (30) | 2.62 | 24,215 |
| 95 (35) | 2.38 | 19,657 |
| 104 (40) | 2.15 | 16,043 |
| 113 (45) | 1.92 | 13,161 |
| 122 (50) | 1.71 | 10,050 |
| 131 (55) | 1.51 | 8990 |
| 140 (60) | 1.33 | 7487 |
| 149 (65) | 1.17 | 6265 |
| 158 (70) | 1.03 | 5260 |
| 167 (75) | .90 | 4450 |
| 176 (80) | .78 | 3775 |
| 185 (85) | .69 | 3215 |
| 194 (90) | .60 | 2750 |
| 200 (95) | .52 | 2361 |
| (1) Value may vary by 15 percent. |
| (1) | Value may vary by 15 percent. |
TOT SENSOR (AXODE) SPECIFICATIONS
EVR SENSOR
| Application | Ohms |
| 5.8L | 20-45 |
HEATED EXHAUST GAS OXYGEN (HEGO) SENSOR
| Condition | (1) Voltage |
| Increasing Engine Speed | Increases |
| Decreasing Engine Speed | Decreases |
| Engine At Idle | 0.2-0.6 |
| (1) Measure between HEGO sensor and ground. |
| (1) | Measure between HEGO sensor and ground. |
HEATED EXHAUST GAS OXYGEN SENSOR VOLTAGE