FLOOR
When FLOOR is selected
- The air inlet blend door is at no vacuum, blocking recirculated air and allowing outside air.
- The footwell airflow door is at the full vacuum position, opening the door and allowing airflow through the footwell ducts.
- The defrost airflow door and the vent/register blend door are in the no vacuum position, closing off airflow to the windshield defroster hose nozzles and driver, passenger and center registers.
- The temperature control can be positioned to mix air flowing through and around the heater core to achieve the selected temperature level.
- The A/C compressor is disabled.
- The blower motor is ON.