Home/Ford/Escape/Ford Escape I (2000-2004)/Repair manual/Charging System/Charging System - Generators & Regulators: Specifications
Contents Wiring diagrams Section: Charging System All sections

Charging System - Generators & Regulators: Specifications Ford Escape I

GENERATOR SPECIFICATIONS

ApplicationSpecification
Generator Amperage Rating110 Amps
Load Test (1)
With Tester Load (2)(3)
Without Tester Load (4)(5)
No-Load Test (1) (2)13-15 Volts
(1) All tests are performed with engine running at 2000 RPM. (2) All accessories off. (3) Adjust tester load bank to determine generator output. (4) Perform this test with engine running, A/C on, blower motor on high speed, and headlamps on high beam. (5) With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.
(1)All tests are performed with engine running at 2000 RPM.
(2)All accessories off.
(3)Adjust tester load bank to determine generator output.
(4)Perform this test with engine running, A/C on, blower motor on high speed, and headlamps on high beam.
(5)With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.

GENERATOR SPECIFICATIONS

TORQUE SPECIFICATIONS

ApplicationFt. Lbs. (N.m)
Generator Bolts
2.0L (Lower)35 (47)
2.0L (Upper)18 (24)
3.0L35 (47)
Generator Mounting Bracket Bolts15 (20)
INCH Lbs. (N.m)
Generator Terminal B+ Nut71 (8)
Powertrain Control Module Bolts & Nuts53 (6)

TORQUE SPECIFICATIONS