Home/Ford/Bronco/Ford Bronco V (1992-1996)/Repair manual/Sensor Range Charts/Engine Controls - Sensor Operating Range Charts: Other
Contents Wiring diagrams Section: Sensor Range Charts All sections

Engine Controls - Sensor Operating Range Charts: Other Ford Bronco V

DPFE SENSOR

Pressure Differential (PSI)(1) Volts
4.344.56
3.253.54
2.172.51
1.081.48
00.45
(1) Sensor voltages are based on a Voltage Reference (VREF) of 5 volts. Actual values may differ by as much as 15 percent because of sensor and VREF variations.
(1)Sensor voltages are based on a Voltage Reference (VREF) of 5 volts. Actual values may differ by as much as 15 percent because of sensor and VREF variations.

DPFE SENSOR VOLTAGE

ECT & IAT SENSORS

Temperature: °F (°C)(1) VoltsOhms
50 (10)3.5258,750
68 (20)3.0637,300
86 (30)2.6224,270
104 (40)2.1616,150
122 (50)1.7210,970
140 (60)1.357600
158 (70)1.045370
176 (80)0.803840
194 (90)0.612800
212 (100)0.462070
230 (110)0.361550
248 (120)0.281180
(1) Sensor voltages are based on a Voltage Reference (VREF) of 5 volts. Actual values may differ by as much as 15 percent because of sensor and VREF variations.
(1)Sensor voltages are based on a Voltage Reference (VREF) of 5 volts. Actual values may differ by as much as 15 percent because of sensor and VREF variations.

IAT & ECT SENSORS SPECIFICATIONS

EGR TEMPERATURE (EGRT) SENSOR

Coolant Temperature °F (°C)M Ohms
68-120 (20-49)2.25-2.55
130-148 (55-65)1.75-2.25
150-165 (66-74)1.40-1.75
168-190 (76-88)1.00-1.40

EGRT SENSOR RESISTANCE SPECIFICATIONS

EVP VALVE POSITION SENSOR

EGR Valve Opening (%)(1) Volts
00.40
100.75
201.10
301.45
401.80
502.15
602.50
702.85
803.20
903.55
1003.90
(1) Sensor voltages are based on a Voltage Reference (VREF) of 5 volts. Actual values may differ by as much as 15 percent because of sensor and VREF variations.
(1)Sensor voltages are based on a Voltage Reference (VREF) of 5 volts. Actual values may differ by as much as 15 percent because of sensor and VREF variations.

EVP SENSOR VOLTAGE

HEATED OXYGEN SENSOR (HO2S)

Condition(1) Voltage
RichIncreases
LeanDecreases
(1) Measure between oxygen sensor connector and ground. Voltage should toggle above and below 0.45 volt when system is in closed loop.
(1)Measure between oxygen sensor connector and ground. Voltage should toggle above and below 0.45 volt when system is in closed loop.

HO2S VOLTAGE

MASS AIRFLOW (MAF) SENSOR

Engine Condition (1)(2) Volts
Idle0.8
20 MPH1.0
40 MPH1.7
60 MPH2.1
(1) Engine at normal operating temperature. (2) Voltage may differ depending on engine load and temperature.
(1)Engine at normal operating temperature.
(2)Voltage may differ depending on engine load and temperature.

MAF SENSOR VOLTAGE

MAP/BARO PRESSURE SENSOR

Barometric Pressure (In. Hg)(1) Frequency (Hz)
17.1122.4
18.3125.5
19.5128.7
20.7131.9
21.8135.1
23.0138.3
24.2141.8
25.4145.4
26.6148.9
27.7152.5
28.9156.1
30.1159.6
31.0162.4
(1) Values may differ by as much as 6 Hz.
(1)Values may differ by as much as 6 Hz.

MAP/BARO FREQUENCY (BAROMETRIC PRESSURE)

Manifold Vacuum (In. Hg)(2) Frequency (Hz)
0159
3150
6141
9133
12125
15117
18109
21102
2495
2788
3080
(1) Based on barometric pressure of 30.0 in. Hg. (2) Values may differ by as much as 6 Hz.
(1)Based on barometric pressure of 30.0 in. Hg.
(2)Values may differ by as much as 6 Hz.

MAP/BARO FREQUENCY (MANIFOLD VACUUM) (1)

Elevation (Feet)Volts
01.59
10001.56
20001.53
30001.50
40001.47
50001.44
60001.41
70001.39

MAP/BARO VOLTAGE

MANUAL LEVER POSITION (MLP) SENSOR

Position(1) Volts(1) Ohms
P4.414160
R3.601440
N2.83733
D2.09401
21.37211
10.6881
(1) Values may differ by as much as 15 percent.
(1)Values may differ by as much as 15 percent.

MLP SENSOR SPECIFICATIONS

PRESSURE FEEDBACK EGR (PFE) SENSOR

Psi (1)Volts
1.82 psi4.75
1.364.38
0.914.00
0.463.63
In. Hg (2)Volts
03.25
5.01.22
7.40.25
(1) To avoid sensor damage, DO NOT exceed 1.82 psi Hg during testing. (2) To avoid sensor damage, DO NOT exceed 7.40 in. Hg during testing.
(1)To avoid sensor damage, DO NOT exceed 1.82 psi Hg during testing.
(2)To avoid sensor damage, DO NOT exceed 7.40 in. Hg during testing.

PFE SENSOR VOLTAGE

THROTTLE POSITION SENSOR (TPS)

Throttle Angle(1) Volts
0.50
10°0.97
20°1.44
30°1.90
40°2.37
50°2.84
60°3.31
70°3.78
80°4.24
(1) Voltage may differ by as much as 15 percent.
(1)Voltage may differ by as much as 15 percent.

TPS VOLTAGE