TX FAILURE (ACTIVE)
When Monitored: When the ignition is on.
Set Condition: This DTC will set if the A/C - Heater Control Module is unable to send a PCI Bus message.
- ATTEMPT TO COMMUNICATE WITH THE HVAC MODULE
- CHECK FOR ADDITIONAL HVAC DTCS
- ATTEMPT TO COMMUNICATE WITH THE PCM AND MIC
- A/C - HEATER CONTROL MODULE
- INTERMITTENT WIRING PROBLEM
Scheme 312
Scheme 313
- CHECK FOR INSTRUMENT CLUSTER (MIC) DTCS
- INOPERATIVE BULB(S)
- A/C - HEATER CONTROL MODULE
- PANEL LAMPS DRIVER CIRCUIT OPEN
- INSTRUMENT CLUSTER
Scheme 314
Scheme 315
- AC COOLDOWN TEST NEEDS TO BE RUN
- HVAC DOOR RECALIBRATION NEEDS TO BE RUN
Scheme 316
Scheme 317
- HVAC DOOR RECALIBRATION FAILED
- A/C - HEATER CONTROL MODULE
Scheme 318
- CHECK FOR ACTUATOR CIRCUIT TEST FAULT MESSAGES
- CHECK FOR ACTIVE HVAC DTCS
- CHECK FOR HVAC DOOR RECALIBRATION FAULT MESSAGES
- MODE DOOR ACTUATOR(S)/LINKAGE(S)/DOOR(S)
- PASSENGER BLEND DOOR ACTUATOR/LINKAGE/DOOR
- DRIVER BLEND DOOR ACTUATOR/LINKAGE/DOOR
- RECIRCULATION DOOR ACTUATOR/LINKAGE/DOOR
Scheme 319
Scheme 320
Scheme 321
- CHECK FOR ACTUATOR CIRCUIT TEST FAULT MESSAGES
- CHECK FOR ACTIVE HVAC DTCS
- CHECK FOR HVAC DOOR RECALIBRATION FAULT MESSAGES
- MODE DOOR ACTUATOR(S)/LINKAGE(S)/DOOR(S)
- BLEND DOOR ACTUATOR/LINKAGE/DOOR
- RECIRCULATION DOOR ACTUATOR/LINKAGE/DOOR
Scheme 322
Scheme 323
Scheme 324
- IPM FUSE #4
- BLOWER MOTOR FEED CIRCUIT SHORTED TO GROUND
- FUSED B(+) SHORTED TO GROUND
- BLOWER MOTOR SHORTED TO GROUND
- BLOWER MOTOR
- BLOWER MOTOR HIGH DRIVER CIRCUIT OPEN
- GROUND CIRCUIT OPEN
- A/C - HEATER CONTROL MODULE OPEN
- BLOWER MOTOR FEED CIRCUIT OPEN
- FUSED B(+) CIRCUIT OPEN
- IGNITION SWITCH OPEN
Scheme 325
Scheme 326
Scheme 327
- BLOWER MOTOR DRIVER CIRCUIT(S) SHORTED TO GROUND
- A/C - HEATER CONTROL MODULE
- BLOWER MOTOR DRIVER CIRCUIT(S) SHORTED TO VOLTAGE
- BLOWER MOTOR DRIVER CIRCUITS SHORTED TOGETHER
- A/C - HEATER CONTROL MODULE - SPEEDS INCORRECT
- BLOWER MOTOR DRIVER CIRCUIT(S) OPEN
- BLOWER MOTOR RESISTOR BLOCK - OPEN SPEED
Scheme 328
Scheme 329
- ATTEMPT TO COMMUNICATE WITH THE PCM
- CHECK FOR HVAC RELATED DTCS IN THE PCM
- CHECK FOR ACTIVE HVAC DTCS AND SYSTEM TEST FAULT MESSAGES
- CHECK FOR HVAC RELATED DTCS IN THE PCM
- MANUAL A/C SYSTEM TEST
Scheme 330
Scheme 331
- CHECK FUSE #13
- OPEN FUSED B+ CIRCUITS
- FRONT CONTROL MODULE
Scheme 332
- CHECK FUSE #11
- OPEN FUSED B+ CIRCUITS
- FRONT CONTROL MODULE
Scheme 333
- OPEN B+ CIRCUIT
- FRONT CONTROL MODULE