Monitor Conditions
- When Monitored: With the ignition on.
Set Conditions
- Set Condition: The Totally Integrated Power Module (TIPM) detects a short to ground on the Wiper Park Switch Sense circuit.
Possible Causes
| Possible Causes |
|---|
| (W7) WIPER PARK SWITCH SENSE CIRCUIT SHORT TO GROUND |
| FRONT WIPER MOTOR |
| TOTALLY INTEGRATED POWER MODULE |
- When Monitored: With the ignition on.
- Set Condition: The Totally Integrated Power Module (TIPM) does not detect a change from High to Low voltage on the Wiper Park Switch Sense Circuit.
| Possible Causes |
|---|
| (W7) WIPER PARK SWITCH SENSE CIRCUIT OPEN |
| (W7) WIPER PARK SWITCH SENSE CIRCUIT SHORTED TO VOLTAGE |
| FRONT WIPER MOTOR |
| TOTALLY INTEGRATED POWER MODULE |
- When Monitored: With the ignition on.
- Set Condition: The Totally Integrated Power Module (TIPM) detects a short to ground on the Rear Wiper Park Switch Sense circuit.
| Possible Causes |
|---|
| (W17) REAR WIPER PARK SWITCH SENSE CIRCUIT SHORTED TO GROUND |
| REAR WIPER MOTOR |
| TOTALLY INTEGRATED POWER MODULE |
- When Monitored: With the ignition on.
- Set Condition: The Totally Integrated Power Module (TIPM) does not detect a change from High to Low voltage on the Rear Wiper Park Switch Sense Circuit.
| Possible Causes |
|---|
| (W17) REAR WIPER PARK SWITCH SENSE CIRCUIT OPEN |
| (W17) REAR WIPER PARK SWITCH SENSE CIRCUIT SHORTED TO VOLTAGE |
| REAR WIPER MOTOR |
| TOTALLY INTEGRATED POWER MODULE |
- When Monitored: With the Headlamp Washers activated.
- Set Condition: When the Totally Integrated Power Module (TIPM) detects an HIGH condition.
| Possible Causes |
|---|
| (W24) HEADLAMP WASHER RELAY CONTROL CIRCUIT OPEN |
| (W24) HEADLAMP WASHER RELAY CONTROL CIRCUIT SHORTED TO VOLTAGE |
| (W23) HEADLAMP WASHER MOTOR CONTROL CIRCUIT OPEN |
| (W23) HEADLAMP WASHER MOTOR CONTROL CIRCUIT SHORTED TO VOLTAGE |
| HEADLAMP WASHER RELAY |
| TOTALLY INTEGRATED POWER MODULE |