B210D-BATTERY VOLTAGE LOW
For a complete wiring diagram Refer to SYSTEM WIRING DIAGRAMS .
- When Monitored: With the ignition on.
- Set Condition: Battery voltage less than 9 volts for more than 15 seconds.
Possible Causes
- RESISTANCE IN THE (A1) BATTERY POSITIVE CIRCUIT
- RESISTANCE IN THE GENERATOR CASE GROUND
- GENERATOR OPERATION
- (K20) GENERATOR FIELD CONTROL CIRCUIT OPEN
- (K20) GENERATOR FIELD CONTROL CIRCUIT SHORTED TO GROUND
- (Z20) GROUND CIRCUIT OPEN
- PCM
B210E-BATTERY VOLTAGE HIGH
For a complete wiring diagram Refer to SYSTEM WIRING DIAGRAMS .
- When Monitored: With the ignition on.
- Set Condition: Battery voltage greater than 16 volts for more than 15 seconds.
Possible Causes
- (K20) GENERATOR FIELD CONTROL CIRCUIT SHORTED TO BATTERY VOLTAGE GENERATOR
- PCM