Schematic diagram
(1) heater matrix
(2) water inlet housing
(3) exhaust gas/water exchanger
(4) bleed screw(s)
(5) coolant outlet housing
(6) additional heating (according to equipment)
(7) radiator
(8) water-to-air heat exchanger
(9) coolant/oil heat exchanger
(10) expansion chamber
Data
| - | data |
|---|---|
| total capacity of circuit | 10,7 litres |
| 11,7 litres (version with additional heating) | |
| radiator surface area | 21 dm2 |
| pressurisation | 1,4 bar |
| opening of thermostatic regulator | 83 °C |
| description | data |
|---|---|
| number x electrical power | 1 x 550 W |
| 1st gear | 97 °C |
| 2nd speed | 105 °C |
| description | data |
|---|---|
| number x electrical power | 1 x 550 W |
| 1st gear | 97 °C or air conditioning in operation |
| 2nd speed | 101 °c or 17 bar in the cooling circuit |
| 3rd speed | 105 °C or air conditioning in operation |
| air conditioning cut-off | 115 °c or 30 bar in the cooling circuit |
| warning | 118 °C |
| post-cooling | 6 minutes |
| temperature sensor | temperature: diesel injection, warning, heating/ventilation |
| connector colour | Green |