Contents Wiring diagrams Section: Body Electrical All sections

Accessory Power Socket: Other Chevrolet Traverse I

Body Electrical ~458 words

Intermittent

Electrical connections or wiring may be the cause of intermittent conditions. Refer to Testing for Intermittent Conditions and Poor Connections

Reference Information

Schematic Reference

Cigar Lighter/Power Outlet Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Power Outlets Description and Operation

Electrical Information Reference

  1. «Circuit Testing»(ref-365275-S00040570812010070600000)
  2. «Connector Repairs»(ref-365275-S19060558252010070600000)
  3. «Testing for Intermittent Conditions and Poor Connections»(ref-365275-S00287822652010070600000)
  4. «Wiring Repairs»(ref-365275-S21384576672010070600000)

Repair Procedures

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

Cigar Lighter Receptacle or 12-Volt Accessory Power Receptacle Replacement

Schematic Reference

Cigar Lighter/Power Outlet Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Power Outlets Description and Operation

Electrical Information Reference

  1. «Circuit Testing»(ref-365275-S00040570812010070600000)
  2. «Connector Repairs»(ref-365275-S19060558252010070600000)
  3. «Testing for Intermittent Conditions and Poor Connections»(ref-365275-S00287822652010070600000)
  4. «Wiring Repairs»(ref-365275-S21384576672010070600000)

Circuit/System Verification

  1. Ignition ON, connect an AC power extension cord to the X81 accessory power receptacle - 110 V AC. Inserting the extension cord plug into the X81 accessory power receptacle - 110 V AC turns the T1 accessory DC/AC power inverter module ON.
  2. Test for 110-120 V between the terminals at the extension cord.
  3. Test for 59-61 Hz AC across the line A and line B terminals of the extension cord.

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

  1. «120-Volt Accessory Power Receptacle Replacement»(ref-365292-S04271575892010070600000)
  2. «Accessory AC and DC Power Control Module Replacement»(ref-365292-S36321531432010070600000)
  3. «Control Module References»(ref-365276-S01454229382010070600000) for control module replacement, setup, and programming

Tools Required

J 42059 Cigar Lighter Socket Remover. See Special Tools .

110 Volt Power Outlet Receptacle Isolation Fault Protection

The accessory DC/AC power inverter module contains a ground fault circuit interrupter (GFCI). GFCI monitors the 110 V circuit for a short to vehicle chassis ground. If a 110 V AC short to ground is detected, the accessory DC/AC power inverter module will turn OFF. The module remains OFF, until the AC powered device is unplugged from the outlet, and then plugged into the outlet after a 3 second delay.

110 Volt Power Outlet Receptacle Overload Shutdown

The accessory DC/AC power inverter module will turn OFF if the current in the 110 V circuit is greater than 3.8 A for 1 second, or 2.5 A for 10 seconds. The module will turn ON again, when the AC powered device is unplugged from the outlet, and then plugged into the outlet after a 3 second delay.

110 Volt Power Outlet Receptacle Internal Shutdown

The accessory DC/AC power inverter module will turn OFF if the B+ supply voltage is greater than 16.5 V or less than 11 V. The module will also turn OFF if the device temperature is greater than 85°C (185°F). The module will turn ON again, after the shutdown condition is corrected, and the AC powered device is unplugged from the outlet, and then plugged into the outlet.