Contents Section: Specifications All sections

E4mc 4-bbl Specification Chevrolet Pickup R10

5.0L V8, (VIN Y)

ApplicationSpecification
17081253
TPS.46 Volts, At curb idle.
ISC
Minimum550, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw4
Vacuum Break
Primary25°
Secondary36°
17081254
TPS.46 Volts, At curb idle.
ISC
Minimum550, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3 3/4
Vacuum Break
Primary25°
Secondary36°
17082253
TPS.46 Volts, At curb idle.
ISC
Minimum550, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3 3/4
Vacuum Break
Primary27°
Secondary41°
17082255
TPS.46 Volts, At curb idle.
ISC
Minimum550, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw4
Vacuum Break
Primary27°
Secondary42°
17083250
TPS.46 Volts, At curb idle.
ISC
Minimum550, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary42°
17083251
TPS.46 Volts, At curb idle.
ISC
Minimum550, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary42°
17083252
TPS.46 Volts, At curb idle.
ISC
Minimum550, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary41°
17083253
TPS.46 Volts, At curb idle.
ISC
Minimum550, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary41°
17083553
TPS.46 Volts, At curb idle.
ISC
Minimum550, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary41°
17084252
TPS.46 Volts, At curb idle.
ISC
Minimum500, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary41°
17084254
TPS.46 Volts, At curb idle.
ISC
Minimum500, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary41°
17084256
TPS.46 Volts, At curb idle.
ISC
Minimum500, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary41°
17084258
TPS.46 Volts, At curb idle.
ISC
Minimum500, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary41°
17084554
TPS.46 Volts, At curb idle.
ISC
Minimum500, In Drive.
Maximum725, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary41°
17085282
TPS.41 Volts, At curb idle.
ISC
Minimum450, In Drive.
Maximum700, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary25°
Secondary43°
17085554
TPS.41 Volts, At curb idle.
ISC
Minimum450, In Drive.
Maximum700, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary27°
Secondary41°
17086008
TPS.7 Volts, At curb idle.
ISC
Minimum450, In Drive.
Maximum700, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary25°
Secondary43°
17086077
TPS.7 Volts, At curb idle.
ISC
Minimum450, In Drive.
Maximum700, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary25°
Secondary43°
17086009
TPS.7 Volts, At curb idle.
ISC
Minimum450, In Drive.
Maximum700, In Drive.
Idle MixtureSet rich stop screw at 4/32".
Set air bleed setting 1.756.
Lean Screw1.304
Idle Screw3
Vacuum Break
Primary25°
Secondary43°

ROCHESTER E4MC CARBURETOR SPECIFICATIONS (5.0L VIN "Y")