Fastener Tightening Specifications

ApplicationSpecification
MetricEnglish
Air Conditioning Compressor and Condenser Hose Bolt2015 lb ft
Air Conditioning Compressor and Condenser Hose Nut2015 lb ft
Air Conditioning Compressor Bolt2216 lb ft
Air Conditioning Compressor Heat Shield Bolt - LTG, LKW7.566 lb in
Air Conditioning Compressor Hose Bolt - LTG, LKW2216 lb ft
Air Conditioning Compressor Hose Nut - LTG, LKW2216 lb ft
Air Conditioning Compressor Hose Retaining Fastener980 lb in
Air Conditioning Compressor Nut2216 lb ft
Air Conditioning Compressor Stud980 lb in
Air Conditioning Compressor Tube Assembly Nut2216 lb ft
Air Conditioning Evaporator Hose Fastener - LUK2015 lb ft
Air Conditioning Evaporator Hose Nut - LTG, LKW2216 lb ft
Air Conditioning Evaporator Hose Stud Bolt - LUK1511 lb ft
Air Conditioning Evaporator Thermal Expansion Valve Bolt762 lb in
Air Conditioning Refrigerant Pressure Sensor7.466 lb in
Air Conditioning Refrigerant Pressure Sensor - LTG, LKW653 lb in
Compressor Pressure Relief Valve870 lb in
Receiver and Dehydrator Plug129 lb ft
Instrument Panel Center Air Outlet Fastener218 lb in

Fastener Tightening Specifications

Refrigerant System Specifications

ApplicationSpecification
MetricEnglish
Abrupt Refrigerant Loss60 ml 12.0 oz 1
PAG Oil GM P/N 12378526 for United States PAG Oil GM P/N 88900060 for Canada
Compressor Replacement
NOTE: Compressor failure can occur if the oil removed during refrigerant recovery is not replaced. The service compressor is shipped with 74 ml 2 (2.5 oz 2 ) or 40 ml 2 (1.4 oz 2 ) of PAG oil. Refer to the oil balance instructions for information regarding the specific service compressor oil charge.
Condenser Replacement30 ml 21.0 oz 2
Evaporator Replacement90 ml 23.0 oz 2
Any Line Set (Hose/Tube or Tube Assembly) Replacement30 ml 21.0 oz 2
Total System PAG Oil Capacity150.0 ml5.1 oz
R-134a
Refrigerant Charge0.68 kg1.50 lb
1 Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component. 2 If more than the specified amount of PAG oil was drained from a component, add the amount drained.
NOTE
Compressor failure can occur if the oil removed during refrigerant recovery is not replaced.