Contents Wiring diagrams Section: Sensor Range Charts All sections

Engine Controls - Sensor Operating Range Charts Chevrolet Corvette C4

INTRODUCTION

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it will cause driveability problems.

Note. Unless stated otherwise in test procedure, perform all voltage tests with a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.

SENSOR RANGE CHARTS

Temperature - °F (°C)Ohms
210 (100)185
160 (70)450
100 (38)1800
70 (20)3400
20 (-7)13,500
0 (-18)25,000
40 (-40)100,700
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

COOLANT TEMPERATURE RESISTANCE VALUES (1)

Altitude - FeetVolts
Below 10003.8-5.5
1000-20003.6-5.3
2000-30003.5-5.1
3000-40003.3-5.0
4000-50003.2-4.8
5000-60003.0-4.6
6000-70002.9-4.5
7000-80002.8-4.3
8000-90002.6-4.2
9000-10,0002.5-4.0
(1) Measured at sensor, or as seen on Scan tester.
(1)Measured at sensor, or as seen on Scan tester.

MAP SENSOR VOLTAGE RANGE (1)

Temperature - °F (°C)Ohms
210 (100)185
160 (70)450
100 (38)1800
70 (20)3400
40 (4)7500
20 (-7)13,500
0 (-18)25,000
40 (-40)100,700
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

MANIFOLD AIR TEMPERATURE SENSOR RESISTANCE VALUES (1)

Temperature - °F (°C)Ohms
210 (100)185
160 (70)450
100 (38)1800
70 (20)3400
40 (4)7500
20 (-7)13,500
0 (-18)25,000
40 (-40)100,700
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

OIL TEMPERATURE SENSOR RESISTANCE TEST (CORVETTE) (1)

ConditionVolts
Lean.1
Rich.9
(1) Measure voltage between O2 sensor ground and signal terminals at ECM.
(1)Measure voltage between O2 sensor ground and signal terminals at ECM.

OXYGEN SENSOR VOLTAGE TEST (1)

Altitude - FeetVolts
Below 10003.8-5.5
1000-20003.6-5.3
2000-30003.5-5.1
3000-40003.3-5.0
4000-50003.2-4.8
5000-60003.0-4.6
6000-70002.9-4.5
7000-80002.8-4.3
8000-90002.6-4.2
9000-10,0002.5-4.0
(1) Measured at sensor.
(1)Measured at sensor.

PRESSURE SENSOR VOLTAGE RANGE (1)