| Temperature °F (°C) | Ohms |
| 176 (80) | 315 |
| 158 (70) | 435 |
| 140 (60) | 580 |
| 122 (50) | 810 |
| 113 (45) | 940 |
| 104 (40) | 1150 |
| 95 (35) | 1360 |
| 86 (30) | 1600 |
| 77 (25) | 2000 |
| 68 (20) | 2400 |
| 59 (15) | 3000 |
| 50 (10) | 3600 |
| 41 (5) | 4600 |
| 32 (0) | 5700 |
| 23 (-5) | 7400 |
| 14 (-10) | 9800 |
| 5 (-15) | 12,700 |
| 4 (-20) | 16,000 |
| (1) Engine Coolant Temperature (ECT) sensor. (2) Intake Air Temperature (IAT) sensor. (3) Measure resistance across sensor terminals. |
| (1) | Engine Coolant Temperature (ECT) sensor. |
| (2) | Intake Air Temperature (IAT) sensor. |
| (3) | Measure resistance across sensor terminals. |
ECT (1) & IAT (2) SENSOR RESISTANCE (1.0L, 1.3L & 1.8L) (3)
| Temperature °F (°C) | Ohms |
| 284 (140) | 63-68 |
| 248 (120) | 104-113 |
| 220 (105) | 159-172 |
| 200 (94) | 215-235 |
| 180 (83) | 302-334 |
| 160 (72) | 430-480 |
| 140 (60) | 650-730 |
| 120 (49) | 980-1100 |
| 100 (38) | 1500-1700 |
| 80 (27) | 2400-2700 |
| 60 (16) | 3900-4500 |
| 40 (4) | 6600-8400 |
| 20 (-7) | 11,000-15,000 |
| 0 (-18) | 21,000-27,000 |
| 20 (-29) | 39,000-53,000 |
| 40 (-40) | 77,000-109,000 |
| (1) Engine Coolant Temperature (ECT) sensor. (2) Intake Air Temperature (IAT) sensor. (3) Measure resistance across sensor terminals. |
| (1) | Engine Coolant Temperature (ECT) sensor. |
| (2) | Intake Air Temperature (IAT) sensor. |
| (3) | Measure resistance across sensor terminals. |
ECT (1) & IAT (2) SENSOR RESISTANCE (1.9L) (3)
| Temperature °F (°C) | Ohms |
| 212 (100) | 177 |
| 194 (90) | 241 |
| 176 (80) | 332 |
| 158 (70) | 467 |
| 140 (60) | 667 |
| 122 (50) | 973 |
| 113 (45) | 1188 |
| 104 (40) | 1459 |
| 95 (35) | 1802 |
| 86 (30) | 2238 |
| 77 (25) | 2796 |
| 68 (20) | 3520 |
| 59 (15) | 4450 |
| 50 (10) | 5670 |
| 41 (5) | 7280 |
| 32 (0) | 9420 |
| 23 (-5) | 12,300 |
| 14 (-10) | 16,180 |
| 5 (-15) | 21,450 |
| 4 (-20) | 28,680 |
| 22 (-30) | 52,700 |
| 40 (-40) | 100,700 |
| (1) Engine Coolant Temperature (ECT) sensor. (2) Intake Air Temperature (IAT) sensor. (3) Transaxle Fluid Temperature (TFT) sensor. (4) Measure resistance across sensor terminals. |
| (1) | Engine Coolant Temperature (ECT) sensor. |
| (2) | Intake Air Temperature (IAT) sensor. |
| (3) | Transaxle Fluid Temperature (TFT) sensor. |
| (4) | Measure resistance across sensor terminals. |
ECT (1) , IAT (2) & TFT (3) SENSOR RESISTANCE (EXCEPT 1.0L, 1.3L, 1.8L & 1.9L) (4)
| Altitude Feet | Volts |
| Below 1000 | 3.8-5.5 |
| 1000-2000 | 3.6-5.3 |
| 2000-3000 | 3.5-5.1 |
| 3000-4000 | 3.3-5.0 |
| 4000-5000 | 3.2-4.8 |
| 5000-6000 | 3.0-4.6 |
| 6000-7000 | 2.9-4.5 |
| 7000-8000 | 2.8-4.3 |
| 8000-9000 | 2.6-4.2 |
| 9000-10,000 | 2.5-4.0 |
| (1) Measured at sensor or as seen on scan tool. |
| (1) | Measured at sensor or as seen on scan tool. |
MAP SENSOR VOLTAGE (1.9L) (1)
| Temperature °F (°C) | Ohms |
| 212 (100) | 177 |
| 194 (90) | 241 |
| 176 (80) | 332 |
| 158 (70) | 467 |
| 140 (60) | 667 |
| 122 (50) | 973 |
| 113 (45) | 1188 |
| 104 (40) | 1459 |
| 95 (35) | 1802 |
| 86 (30) | 2238 |
| 77 (25) | 2796 |
| 68 (20) | 3520 |
| 59 (15) | 4450 |
| 50 (10) | 5670 |
| 41 (5) | 7280 |
| 32 (0) | 9420 |
| 23 (-5) | 12,300 |
| 14 (-10) | 16,180 |
| 5 (-15) | 21,450 |
| 4 (-20) | 28,680 |
| 22 (-30) | 52,700 |
| 40 (-40) | 100,700 |
| (1) Measure resistance across sensor terminals. |
| (1) | Measure resistance across sensor terminals. |
OIL PRESSURE SENSOR RESISTANCE (5.7L VIN G - CORVETTE) (1)
| Condition | Volts |
| Except Metro, Firefly (Canadian) & Prizm |
| Lean | 0.1 |
| Rich | 1.0 |
| Metro, Firefly (Canadian) & Prizm |
| Lean | 100 mV |
| Rich | 900 mV |
| (1) Measure voltage between O2S sensor ground and signal terminals at PCM. |
| (1) | Measure voltage between O2S sensor ground and signal terminals at PCM. |
OXYGEN SENSOR VOLTAGE (1)