Contents Wiring diagrams Section: Sensor Range Charts All sections

Engine Controls - Sensor Operating Range Charts Buick Roadmaster VIII

INTRODUCTION

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it will cause driveability problems.

Note. Unless stated otherwise in test procedure, perform all voltage tests with a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.

Temperature °F (°C)Ohms
212 (100)177
194 (90)241
176 (80)332
158 (70)467
140 (60)667
122 (50)973
113 (45)1188
104 (40)1459
95 (35)1802
86 (30)2238
77 (25)2796
68 (20)3520
59 (15)4450
50 (10)5670
41 (5)7280
32 (0)9420
23 (-5)12,300
14 (-10)16,180
5 (-15)21,450
4 (-20)28,680
22 (-30)52,700
40 (-40)100,700
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

COOLANT TEMPERATURE SENSOR RESISTANCE TEST (1)

Altitude FeetVolts
Below 10003.8-5.5
1000-20003.6-5.3
2000-30003.5-5.1
3000-40003.3-5.0
4000-50003.2-4.8
5000-60003.0-4.6
6000-70002.9-4.5
7000-80002.8-4.3
8000-90002.6-4.2
9000-10,0002.5-4.0
(1) Measured at sensor or as seen on scan tester.
(1)Measured at sensor or as seen on scan tester.

MAP SENSOR VOLTAGE TEST (1)

Temperature °F (°C)Ohms
212 (100)185
160 (70)450
100 (38)1800
70 (20)3400
40 (4)7500
20 (-7)13,500
0 (-18)25,000
40 (-40)100,700
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

MANIFOLD AIR TEMPERATURE SENSOR RESISTANCE TEST (1)

Temperature °F (°C)Ohms
212 (100)185
160 (70)450
100 (38)1800
70 (20)3400
40 (4)7500
20 (-7)13,500
0 (-18)25,000
40 (-40)100,700
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

OIL TEMPERATURE SENSOR RESISTANCE TEST (CORVETTE) (1)

ConditionVolt
Lean.1
Rich.9
(1) Measure voltage between O2 sensor ground and signal terminals at ECM.
(1)Measure voltage between O2 sensor ground and signal terminals at ECM.

OXYGEN SENSOR VOLTAGE TEST (1)