Testing for Electrical Intermittents
Perform the following procedures while wiggling the harness from side to side. Continue this at convenient points (about 6 inches apart) while watching the test equipment.
- «Testing for Short to Ground»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures__testing-for-short-to-ground)
- «Testing for Continuity»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures__testing-for-continuity)
- «Testing for a Short to Voltage»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures__testing-for-a-short-to-voltage)
If the fault is not identified, perform the procedure below using the MIN MAX feature on the J 39200 DMM. See Special Tools and Equipment . This feature allows you to manipulate the circuit without having to watch the J 39200 . See Special Tools and Equipment . The J 39200 will generate an audible tone when a change is detected. See Special Tools and Equipment .
| IMPORTANT | The J 39200 must be used in order to perform the following procedure since the. See Special Tools and Equipment . J 39200 can monitor current, resistance or voltage while recording the minimum (MIN), and maximum (MAX) values measured. See Special Tools and Equipment . |
- Connect the J 39200 to both sides of a suspected connector (still connected), or from one end of a suspected circuit to the other. See «Special Tools and Equipment»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures) . Refer to «Troubleshooting with a Digital Multimeter»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures__troubleshooting-with-a-digital-multimeter) for information on connecting the J 39200 to the circuit. See «Special Tools and Equipment»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures) .
- Set the rotary dial of the J 39200 to the V (AC) or V (DC) position. See «Special Tools and Equipment»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures) .
- Press the range button of the J 39200 in order to select the desired voltage range. See «Special Tools and Equipment»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures) .
- Press the MIN MAX button of the J 39200 . See «Special Tools and Equipment»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures) . The J 39200 displays 100 ms RECORD and emits an audible tone (beep). See «Special Tools and Equipment»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures) . IMPORTANT: The 100 ms RECORD mode is the length of time an input must stay at a new value in order to record the full change.
- Simulate the condition that is potentially causing the intermittent connection, either by wiggling the connections or the wiring, test driving, or performing other operations. Refer to «Inducing Intermittent Fault Conditions»(/buick/rendezvous/i-2001-2007/remont/body-electrical/#wiring-systems-diagnostic-information-and-procedures__inducing-intermittent-fault-conditions) .
- Listen for the audible Min Max Alert which indicates that a new minimum or maximum value has been recorded.
- Press the MIN MAX button once in order to display the MAX value and note the value.
- Press the MIN MAX button again in order to display the MIN value and note the value.
- Determine the difference between the MIN and MAX values. If the variation between the recorded MIN and MAX voltage values is 1 volt or greater an intermittent open or high resistance condition exists. Repair the condition as necessary. If the variation between the recorded MIN and MAX voltage values is less than 1 volt an intermittent open or high resistance condition does not exist.