Contents Wiring diagrams Section: Testing & Diagnostics All sections

Waveform (Injector) - 3.1l Mfi VIN [T] Buick Regal III

Testing & Diagnostics 2 illustrations ~265 words

INTRODUCTION

Note. For a tutorial on how to interprete injector waveforms, see WAVEFORMS - INJECTOR PATTERN TUTORIAL found in the GENERAL/GENERAL INFORMATION area. NOTE: To see a list of the other year/make/models these waveform(s) apply to, go to the top of the article.

  1. (Scheme 42)for the waveform.
  2. See the «WAVEFORM DATA TABLE #1»(/buick/regal/iii-1988-1997/remont/testing-diagnostics/#waveform-injector-31l-mfi-vin-t) for supporting data.

The Waveform Data Table is listed first. This table contains supporting information about the waveform illustration and should be used in conjunction with it.

The waveform illustration follows after the table.

Note. A description of the vehicle the waveform came from is not available.

Note. Notice how this "odd" injector bank draws more current than the "even" one listed later. While this isn't ideal, it is still within range (the vehicle still runs well).

ApplicationSpecification
Pattern TypeCurrent
Voltage Base500 Milliamps
Time BaseUnknown
Oscilloscope UsedUnknown
Pattern RepresentsBank Of Injectors
Injector Driver TypeVoltage Controlled
Side of Circuit That Driver SwitchesGround
Injector On-Time ShownN/A
ConditionsUnknown
Cursors On-ScreenYes
Cursors Are MeasuringInjector Current Draw
StatusKnown Good Pattern

WAVEFORM DATA

Injector Waveform (Current) - Cursors Used - Known Good. Scheme 42

Scheme 42: Injector Waveform (Current) - Cursors Used - Known Good
  1. (Scheme 43)for the waveform.
  2. See the «WAVEFORM DATA TABLE #2»(/buick/regal/iii-1988-1997/remont/testing-diagnostics/#waveform-injector-31l-mfi-vin-t) for supporting data.

The Waveform Data Table is listed first. This table contains supporting information about the waveform illustration and should be used in conjunction with it.

The waveform illustration follows after the table.

Note. A description of the vehicle the waveform came from is not available.

Note. Notice how this "even" injector bank draws less current than the "odd" one listed earlier. While this isn't ideal, it is still within range (the vehicle still runs well).

ApplicationSpecification
Pattern TypeCurrent
Voltage Base500 Milliamps
Time BaseUnknown
Oscilloscope UsedUnknown
Pattern RepresentsBank Of Injectors
Injector Driver TypeVoltage Controlled
Side of Circuit That Driver SwitchesGround
Injector On-Time ShownN/A
ConditionsUnknown
Cursors On-ScreenYes
Cursors Are MeasuringInjector Current Draw
StatusKnown Good Pattern

WAVEFORM DATA

Injector Waveform (Current) - Cursors Used - Known Good. Scheme 43

Scheme 43: Injector Waveform (Current) - Cursors Used - Known Good