12 13 Ignition Coil E36
| Ignition coil for non-operating ignition distribution | — | — |
|---|---|---|
| Primary winding resistance | Approx.ohms | 0.8 |
| Secondary winding resistance | — | Not measurable |
| Resistance of Bosch spark plug connector | Approx. kohms | 1+/- 20% |
| Resistance of Bremi spark plug connector | Approx. kohms | 1.8 +/- 20% |
IGNITION COIL E36 TECHNICAL SPECIFICATION
12 14 Electronic Shift Units or Control Units E36
| Pulse sender | — | — |
|---|---|---|
| Coil resistance at 20°C | — | — |
| All models | Ohms | 540 +/- 10% |
| With breakerless ignition distribution | Ohms | 1280 +/- 10% |
| Distance from inductive pulse sender/gear | Mm | 1.0 +/- 0.3 |
ELECTRONIC SHIFT UNITS OR CONTROL UNITS E36 TECHNICAL SPECIFICATION
12 31 Alternator with Drive and Mounting Parts E36
| Rated voltage | V | 14 |
|---|---|---|
| Rated voltage | A/W | 65/91070/98080/112090/1260105/1470115/1610140/1960150/2100 |
| Shielded capacitor | ΜF | 2.2 +/- 20% |
ALTERNATOR WITH DRIVE AND MOUNTING PARTS E36 TECHNICAL SPECIFICATION
12 32 Regulator E36
| Regulated voltage at 1500 rpm engine speed/no electrical devices on (at 30°C to 60°C at regulator) | V | 13.5... 14.2 |
REGULATOR E36 TECHNICAL SPECIFICATION
12 41 Starter Motor with Bracket, Solenoid Switch E36
| Current consumption at term. 50 (with rated voltage) | — | — |
|---|---|---|
| With rated power of 1.4 KW | — | — |
| Pull-in winding | A | 54.5 |
| Hold-in winding | A | 10.5 |
| At rated power of 1.7 KW with intermediate transmission | — | — |
| Pull-in winding | A | 51 |
| Hold-in winding | A | 9.5 |
| With rated power of 1.8 KW | — | — |
| Pull-in winding | A | 50 |
| Hold-in winding | A | 12 |
| With rated power of 2.0 KW | — | — |
| Pull-in winding | A | 54.5 |
| Hold-in winding | A | 10.5 |
STARTER MOTOR WITH BRACKET, SOLENOID SWITCH E36 TECHNICAL SPECIFICATION
| Current consumption at term 50 (with rated voltage) | — | — |
|---|---|---|
| With rated power of 2.2 KW | — | — |
| Pull-in winding | A | 58 |
| Hold-in winding | A | 13 |
| At rated power of 2.2 KW with intermediate transmission | — | — |
| Pull-in winding | A | 60 |
| Hold-in winding | A | 10 |
| At rated power of 2.6 KW with intermediate transmission | — | — |
| Pull-in winding | A | 50 |
| Hold-in winding | A | 12 |
STARTER MOTOR WITH BRACKET, SOLENOID SWITCH E36 TECHNICAL SPECIFICATION
12 41 Starter and Mounting Parts E36
| Rated power | KW | — |
|---|---|---|
| M40, M42, M43, M43TU, M52, M52TU, S50 | KW | 1.4 |
| M41 | KW | 1.8 |
| M50, M52, S52 | KW | 1.7 |
| M51 | KW | 2.2 |
| M57 | KW | — |
| M67 | KW | — |
| S62 | KW | — |
| Axial armature play | Mm | 0.1 ...0.2 |
| Carbon brush length | At least mm | 13 |
| Testing voltage | V | 12 +/- 0.3 |
STARTER AND MOUNTING PARTS E36 TECHNICAL SPECIFICATION
12 61 Oil pressure, oil temperature, oil level display E36
| Switch-on pressure | Bar | 0.2 ...0.5 |
|---|---|---|
| Oil level switch Note: Max. 200 mA testing load. Measured against vehicle ground | — | — |
| Static at connection 1 | — | — |
| Level okay | Kohms | +/- 1% |
| Level too low | Ohms | 0...0.2 |
| Dynamic at connection 2 | — | — |
| Level okay | Ohms | 0...0.2 |
| Level too low | Ohms | Ohms |
OIL PRESSURE, OIL TEMPERATURE, OIL LEVEL DISPLAY E36 SPECIFICATION