17 11 Radiator and Mounting Parts M52TU / M54
| Cap for cooling system | — | — |
|---|---|---|
| Pressure relief valve opens at overpressure to ambient pressure | Bar | 2 +0.1 -0.2 |
| Vacuum valve must open at latest at partial vacuum to ambient pressure | Bar | 0.1 |
| Test pressure, radiator (gauge pressure) | Bar | 2.0 |
RADIATOR AND MOUNTING PARTS M52TU/M54 TECHNICAL SPECIFICATION
17 11 Radiator and Mounting Parts E36 / M50 / M52 / M54
| Cooling system cap | — | — |
|---|---|---|
| Pressure relief valve opens at overpressure to ambient pressure | Bar | 2 +0.1 -0.2 |
| Vacuum valve must open at latest at partial vacuum to ambient pressure | Bar | 0.1 |
| Test pressure, radiator (gauge pressure) | Bar | 1.5 |
| Transmission Oil Cooler (integrated in radiator) Models with automatic transmission | — | — |
| Operating pressure | Bar | 8 |
| Testing pressure | Bar | 12 |
RADIATOR AND MOUNTING PARTS E36/M50/M52/M54 TECHNICAL SPECIFICATION
| Cap for cooling system | — | — |
|---|---|---|
| Pressure relief valve opens at overpressure to ambient pressure | Bar | 2 +0.1 -0.2 |
| Vacuum valve must open at latest at partial vacuum to ambient pressure | Bar | 0.1 |
| Test pressure, radiator (gauge pressure) | Bar | 2.0 |
RADIATOR AND MOUNTING PARTS M52TU/M54 TECHNICAL SPECIFICATION
| Cooling system cap | — | — |
|---|---|---|
| Pressure relief valve opens at overpressure to ambient pressure | Bar | 2 +0.1 -0.2 |
| Vacuum valve must open at latest at partial vacuum to ambient pressure | Bar | 0.1 |
| Test pressure, radiator (gauge pressure) | Bar | 1.5 |
| Transmission Oil Cooler (integrated in radiator) Models with automatic transmission | — | — |
| Operating pressure | Bar | 8 |
| Testing pressure | Bar | 12 |
RADIATOR AND MOUNTING PARTS E36/M50/M52/M54 TECHNICAL SPECIFICATION