64 50 Heating and air conditioning system oil quantity E70 / E71
| Data on the type plant of the air conditioning compressor is definitive for Refrigerant oil Capacity R 134a |
HEATING AND AIR CONDITIONING SYSTEM OIL QUANTITY SPECIFICATIONS
64 51 Heating and air-conditioning unit (evaporator), switching elements
| Resistance as a function of temperature | 5°C | 11.4-11.9 kohms |
|---|---|---|
| Resistance as a function of temperature | 0°C | 8.8-9.2 kohms |
| Resistance as a function of temperature | 5°C | 6.8-7.2 kohms |
| Resistance as a function of temperature | 10°C | 5.3-5.6 kohms |
| Resistance as a function of temperature | 15°C | 4.2-4.5 kohms |
| Resistance as a function of temperature | 20°C | 3.3-3.6 kohms |
| Resistance as a function of temperature | 25°C | 2.6-2.9 kohms |
| Resistance as a function of temperature | 30°C | 2.1-2.3 kohms |
| Resistance as a function of temperature | 35°C | 1.7-1.9 kohms |
HEATING AND AIR-CONDITIONING UNIT (EVAPORATOR), SWITCHING ELEMENTS SPECIFICATIONS
64 51 Heating and air-conditioning unit (expansion valve), switching elements
| Inlet pressure (excess pressure) | Bar | 14 |
|---|---|---|
| Outlet pressure (excess pressure) | Bar | 1.8 |
| Leak test with detector at excess pressure | Bar | 1-2 |
HEATING AND AIR-CONDITIONING UNIT (EXPANSION VALVE), SWITCHING ELEMENTS SPECIFICATIONS
64 50 air conditioning, refrigerant amounts E70, E71
| Refrigerant capacity R 134a (The data on the nameplate in the engine compartment are definitive) | G | 700±10 |
AIR CONDITIONING, REFRIGERANT AMOUNTS SPECIFICATIONS