MSS60 ENGINE OPERATING SYSTEM DTCS
MSS60 ECM applies to 2008-09 M3 with S65 engine. DTC P1602-DTC U1153.
BMW Fault Code (hex)
0x2B56
BMW Fault Code (dez)
11094
BMW Fault Code Description VS-Text
Brake light/test switch, plausibility
Component
No Info.
Subcomponent
No Info.
Monitoring criteria
S BLS != S BLTS
Fault debouncing
400 ms
Terminal conditions
TERM15 TERM87
Voltage conditions
none
Temperature conditions
none
Time conditions
400 ms
System test
none
Signal information
Digital; 0--12V
Calculated value Y/N
N
Possible Fault Causes
BLS signal and/or open BLTS wire, short to positive, short to ground / switch defective
Repair procedures (plant/service)
- Check plug and wiring harness on BLS module
- Replace BLS module
MIL illumination/CC message/emergency program
none
Remarks
none
Customer perception comments
FGR cruise control operation deactivated / depending upon malfunction status, engine can be started without depressing brake, or engine cannot be started / CC message only with BLTS fault
0x2B56
11094
Brake light/test switch, plausibility
No Info.
No Info.
S_BLS_IGN != S_BLS_INJ
400 ms
TERM15 TERM87
none
none
400 ms
none
Digital; 0--12V
N
Error in BLS signal in ECU
- Check plug and wiring harness on BLS module
- Replace BLS module
none
none
FGR cruise control operation deactivated / depending upon malfunction status, engine can be started without depressing brake, or engine cannot be started / CC message only with BLTS fault
0x2B55
11093
Control module, internal fault
ECM Self-Test
ECM
Implausible data
100 ms
Terminal 15
none
none
>100 ms
none
none
Y
Test calculation incorrect or timeout Complementary comparison false
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B57
11095
not translated
No Info.
No Info.
Safety-critical malfunction
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Not a malfunction, only the response: Torque is limited
This fault memory entry is always a collateral error. The only way to rectify it is by resolving the malfunctions behind any other displayed fault memory entries.
EML, CC message, backup program
This fault memory entry is always a collateral error
CC message, Engine speed limited Reduced power
0x2B57
11095
not translated
No Info.
No Info.
Safety-critical malfunction
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Not a malfunction, only the response: Cylinders are suppressed
This fault memory entry is always a collateral error. The only way to rectify it is by resolving the malfunctions behind any other displayed fault memory entries.
EML, CC message, backup program
This fault memory entry is always a collateral error
CC message, Engine speed limited Reduced power
0x2B57
11095
not translated
No Info.
No Info.
Safety-critical malfunction
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Not a malfunction, only the response: E-Gas is deactivated
This fault memory entry is always a collateral error. The only way to rectify it is by resolving the malfunctions behind any other displayed fault memory entries.
EML, CC message, backup program
This fault memory entry is always a collateral error
CC message, Engine speed limited Reduced power
0x2B57
11095
not translated
No Info.
No Info.
Safety-critical malfunction
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Not a malfunction, only the response: Reset was triggered
This fault memory entry is always a collateral error. The only way to rectify it is by resolving the malfunctions behind any other displayed fault memory entries.
EML, CC message, backup program
This fault memory entry is always a collateral error
CC message, Engine speed limited Reduced power
0x2710
10000
Control module, internal fault
No Info.
No Info.
Fault memory entry in ECU log
500 ms
Terminal 15
none
none
> 500 ms
none
none
Y
Error during internal check of malfunction log.
- Clear fault memory
- If error is still present, replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power
0x2AF8
11000
Control module, internal fault
No Info.
No Info.
Fault memory entry in ECU log
500 ms
Terminal 15
none
none
> 500 ms
none
none
Y
Error during internal check of malfunction log.
- Clear fault memory
- If error is still present, replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power
0x2710
10000
Control module, internal fault
No Info.
No Info.
Fault memory entry in ECU log
500 ms
Terminal 15
none
none
> 500 ms
none
none
Y
Error during internal check of malfunction log.
- Clear fault memory
- If error is still present, replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power
0x2AF8
11000
Control module, internal fault
No Info.
No Info.
Fault memory entry in ECU log
500 ms
Terminal 15
none
none
> 500 ms
none
none
Y
Error during internal check of malfunction log.
- Clear fault memory
- If error is still present, replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power
0x2710
10000
Control module, internal fault
No Info.
No Info.
Fault memory entry in ECU log
500 ms
Terminal 15
none
none
> 500 ms
none
none
Y
Error during internal check of malfunction log.
- Clear fault memory
- If error is still present, replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power
0x2AF8
11000
Control module, internal fault
No Info.
No Info.
Fault memory entry in ECU log
500 ms
Terminal 15
none
none
> 500 ms
none
none
Y
Error during internal check of malfunction log.
- Clear fault memory
- If error is still present, replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power
0x2710
10000
Control module, internal fault
No Info.
No Info.
Fault memory entry in ECU log
500 ms
Terminal 15
none
none
> 500 ms
none
none
Y
Error during internal check of malfunction log.
- Clear fault memory
- If error is still present, replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power
0x2AF8
11000
Control module, internal fault
No Info.
No Info.
Fault memory entry in ECU log
500 ms
Terminal 15
none
none
> 500 ms
none
none
Y
Error during internal check of malfunction log.
- Clear fault memory
- If error is still present, replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power
0x2793
10131
Power management, battery
Powermanagement
Electrical
Deep discharge: 60 seconds below 9.52 V monitored at battery sensor under all conditions. (B_ifuplak == 1) || (B_ifsysak == 1) || (B_ifusak == 1)
200 ms
TERM87
none
none
>200 ms
none
Digital - BSD bus
Y
High energy consumption in parked vehicle leads to battery damage.
- Conduct energy diagnosis
- Check control modules for standby current error
- Check battery, replace as indicated.
none
B_ulcp = False, B_ifbsak = False, B_ifuplak = False, B_ibfbsd = False, B_ifsysak = False, B_ifusak = False, B_kwdreht = True
No engine start possible without jumping.
0x2793
10131
Power management, battery
Powermanagement
Electrical
Charge status bit B_soc_npl = TRUE, if ((Soc_quali <= K_QSOCCL2) && ((Soc_quali - Soc_q_kor) > K_QSOCCL3))
200 ms
TERM87
none
none
>200 ms
none
Digital - BSD bus
Y
No measurement of standby current possible, IBS fault
- Check control modules for standby current error
- Replace IBS.
CC status report
none
CC status report
0x2792
10130
Power management, vehicle electrical system
Powermanagement
Electrical
Overvoltage with engine running: Battery voltage > K_OSPGAPP (16V) for 10 seconds and (Ospgprell >= K_OSPGPRELLZ)
200 ms
Engine running
none
none
>200 ms
none
Digital - BSD bus
Y
Defective alternator
- Conduct alternator diagnosis
- Replace alternator
none
B_ulcp = False, B_ifbsak = False, B_ifuplak = False, B_ibfbsd = False, B_ifsysak = False, B_ifusak = False, B_kwdreht = True
Driver does not notice. Various control modules, bulbs, etc. may be damaged (overvoltage)
0x2792
10130
Power management, vehicle electrical system
Powermanagement
Electrical
Undervoltage during engine operation: Battery voltage < K_USPGAPP (10.5V) for 10 seconds and (Uspgprell >= K_USPGPRELLZ)
200 ms
Engine running
none
none
>200 ms
none
Digital - BSD bus
Y
Defective alternator
- DME software version must be more recent than 07--06--510, remedial action starting with 07--09--521
- Carry out alternator diagnosis
- Replace alternator
none
B_ulcp = False, B_ifbsak = False, B_ifuplak = False, B_ibfbsd = False, B_ifsysak = False, B_ifusak = False, B_kwdreht = True
Driver does not notice.
0x2792
10130
Power management, vehicle electrical system
Powermanagement
Electrical
Engine runs without battery: Voltage fluctuations owing to poor battery contacts (B_bns = TRUE)
200 ms
Engine running
none
none
>200 ms
none
Digital - BSD bus
Y
Battery not connected correctly/contacts not tightened down adequately
- Check battery terminals and battery
CC status report
B_ulcp = False, B_ifbsak = False, B_ifuplak = False, B_ibfbsd = False, B_ifsysak = False, B_ifusak = False, B_kwdreht = True
CC status report
0x279D
10141
Power management, closed-circuit current violation
Powermanagement
Electrical
from IBS data storage: T2histiruh >= KL_T2RELMAX(T_histsum) or T3histiruh >= KL_T3RELMAX(T_histsum) or T4histiruh >= KL_T4RELMAX(T_histsum) or then B_ruhverl -> Error logged in ECU
200 ms
TERM87
none
none
>200 ms
none
Digital - BSD bus
Y
Increased energy consumption (possibly unregistered power consumers) when parked
- Conduct energy diagnosis r
- Check control modules for standby current errors
- Seek out standby current violators
CC status report
from IBS data storage: T_histsummin >= K_T_RUHAUSW
CC status report: High battery discharge when parked, engine start may no longer be possible
0x2B28
11048
Throttle valves, test of return springs, bank 2
Throttle Actuator
Adaptation
Closing duration too low
20 ms
TERM87
none
none
>20 ms
DK test routine
none
Y
Defective springs / friction in throttle valve assembly
- Clear fault memory, EDR electronic throttle valve control system test
- Check throttle valve assembly for friction
- Replace EDR B1
MIL, EML, CC message, backup program
Tmot > -50 °C K_EGAS_STM_DK_FT_TMOT
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B28
11048
Throttle valves, test of return springs, bank 2
Throttle Actuator
Spring Test
Time violation
20 ms
TERM87
none
none
>20 ms
DK test routine
none
Y
Fault in actuator
- Clear fault memory, EDR electronic throttle valve control system test
- Check throttle valve assembly for friction
- Replace EDR B2
MIL, EML, CC message, backup program
Tmot > -50 °C K_EGAS_STM_DK_FT_TMOT
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B22
11042
Throttle-valve actuator pre-drive check, bank 2
Throttle Actuator
Spring Test
Wire permanently disabled
300 ms
TERM87
none
none
>300 ms
DK test routine
none
Y
Problem with Enable wire
- Check enable wire B2
- Clear fault memory, perform EDR electronic throttle valve control system test
- Replace EDR2
MIL, EML, CC message, backup program
CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B22
11042
Throttle-valve actuator pre-drive check, bank 2
Throttle Actuator
Spring Test
Wire permanently enabled
300 ms
TERM87
none
none
>300 ms
DK test routine
none
Y
Problem with Enable wire
- Check enable wire B2
- Clear fault memory, perform EDR electronic throttle valve control system test
- Replace EDR2
MIL, EML, CC message, backup program
CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B22
11042
Throttle-valve actuator pre-drive check, bank 2
Throttle Actuator
Spring Test
Wire does not expedite Disable
80 ms
TERM87
none
none
>80 ms
DK test routine
none
Y
Problem with Enable wire
- Check enable wire B2
- Clear fault memory, perform EDR electronic throttle valve control system test
- Replace EDR2
MIL, EML, CC message, backup program
CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B22
11042
Throttle-valve actuator pre-drive check, bank 2
Throttle Actuator
Spring Test
Plates do not move
80 ms
TERM87
Battery voltage > 9V (k_egas_stm_dk_gt_ub)
Tmot > -50 °C (k_egas_stm_dk_gt_tmot)
>80 ms
DK test routine
none
Y
Mechanical connection between EDR B2 and DK B2 ripped apart, friction, substantial play/contact resistance in power supply to EDR B2
- Check DK throttle valve assembly for mechanical resistance and mechanical connection
- Check plug, wiring harness and power supply
- Clear fault memory, EDR electronic throttle valve control system test
- Replace throttle valve sensor DKG2
- Clear fault memory, EDR system test
- Replace EDR2
MIL, EML, CC message, backup program
CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B21
11041
Throttle-valve actuator pre-drive check, bank 1
Throttle Actuator
Spring Test
Wire permanently disabled
300 ms
TERM87
none
none
>300 ms
DK test routine
none
Y
Enable wire shorted to UBatt or open wire
- Check enable wire B1
- Clear fault memory, perform EDR electronic throttle valve control system test
- Replace EDR1
MIL, EML, CC message, backup program
CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B21
11041
Throttle-valve actuator pre-drive check, bank 1
Throttle Actuator
Spring Test
Wire permanently enabled
300 ms
TERM87
none
none
>300 ms
DK test routine
none
Y
Enable wire has short to ground
- Check enable wire B1
- Clear fault memory, perform EDR electronic throttle valve control system test
- Replace EDR1
MIL, EML, CC message, backup program
CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B21
11041
Throttle-valve actuator pre-drive check, bank 1
Throttle Actuator
Spring Test
Wire does not expedite Disable
80 ms
TERM87
none
none
>80 ms
DK test routine
none
Y
Problem with Enable wire
- Check enable wire B1
- Clear fault memory, perform EDR electronic throttle valve control system test
- Replace EDR1
MIL, EML, CC message, backup program
CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B21
11041
Throttle-valve actuator pre-drive check, bank 1
Throttle Actuator
Spring Test
Plates do not move
80 ms
TERM87
Battery voltage > 9V (k_egas_stm_dk_gt_ub)
Tmot > -50 °C (k_egas_stm_dk_gt_tmot)
>80 ms
DK test routine
none
Y
Mechanical connection between EDR B1 and DK B1 ripped apart, friction, substantial play/contact resistance in power supply to EDR B1
- Check DK throttle valve assembly for mechanical resistance, check mechanical connection
- Check plug, wiring harness and power supply
- Clear fault memory, EDR electronic throttle valve control system test
- Replace throttle vale sensor DKG1
- Clear fault memory, EDR system test
- Replace EDR1
MIL, EML, CC message, backup program
CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B5D
11101
Cruise control, deactivation
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2B5F
11103
Start lead CAS activation, electrical diagnosis
No Info.
No Info.
Driver diagnosis ATIC39
1000 ms
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
>1000 ms
none
Digital
N
Current flow too high/ activation wire shorted to battery voltage/defective CAS
- Check plug and wiring harness to CAS
- Replace CAS
none
Engine fails to run
Possible start delay may be noticed
0x2B62
11106
Servotronic, converter current
No Info.
No Info.
Current through converter valve greater than/equal to threshold K_SERVO_STROM_DIAG_KS_UB although no triggering signal or servo_tast == 0
20 ms
TERM87
Battery voltage > K_ED_UBMIN (9.0V)
none
>20 ms
none
Analog; 45--890mA PWM; servo_tast
N
Converter has short to battery voltage
- Check plug and wiring harness connected to converter valve
- Replace converter valve
- Clear fault memory
none
No tester triggering active, no test stand operation, error has not yet appeared in this driving cycle
Steers hard
0x2B63
11107
Servotronic, roadspeed signal
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2B5D
11101
Cruise control, deactivation
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2B5F
11103
Start lead CAS activation, electrical diagnosis
No Info.
No Info.
Driver diagnosis ATIC39
1000 ms
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
>1000 ms
none
Digital
N
Voltage too low/activation wire shorted to ground/defective CAS
- Check plug and wiring harness to CAS
- Replace CAS
none
Engine running
Driver does not notice
0x2B61
11105
Transmission input-speed sensor/slipping clutch
No Info.
No Info.
Transmission input RPM deviates from engine RPM by more than K_N_GETR_HS_DIAG_N RPM in neutral and by more than K_N_GETR_HS_DIAG_N_KS RPM when gear is engaged
100 ms
TERM87
none
none
Tolerance for deviation between transmission input RPM and engine RPM longer than 1.2 seconds
none
PWM
N
Excessive deviation between transmission input RPM and engine RPM, although these should be virtually identical
- Transmission input RPM sensor must be newer than March, 2008, fix incorporated since model year 03/08
- Check plug and wiring harness to sensor
- Replace sensor
- Check clutch (also under load)
- Clear fault memory
- Check FGR cruise control
none
Clutch engaged No error logged in ECU for transmission neutral gate switch, clutch switch or crankshaft sensor
FGR cruise control cannot be activated
0x2B62
11106
Servotronic, converter current
No Info.
No Info.
Current through converter valve below border i = f(Tast*Ub): servo_current + K_SERVO_STROM_DIAG_MIN_OF FSET < (servo_tast * ub * K_SERVO_DIAG_MIN_TAST/4096
20 ms
TERM87
Battery voltage > K_ED_UBMIN (9.0V)
none
>20 ms
none
Analog; 45--890mA PWM; servo_tast
N
Converter valve has shunt current to ground
- Check plug and wiring harness connected to converter valve
- Replace converter valve
- Clear fault memory
none
Converter must be under current, no tester triggering active, no test stand operation, error has not yet appeared in this driving cycle
Steers hard
0x2B63
11107
Servotronic, roadspeed signal
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2B5C
11100
Throttle valves fault status, bank 2
Throttle Actuator
Position Control
Implausible WDK
200 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>200 ms
DK test routine
Analog; 0.2--4.8V
N
Defective DKG throttle valve sensor / Contact resistance in plug connection or wiring harness
- Check wiring harness plug for throttle valve sensor DKG2
- Replace DKG2
EML, CC message, backup program
Pot comparison error present
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B5D
11101
Cruise control, deactivation
No Info.
No Info.
Load dump usually in response to other malfunctions.
10 ms/100 ms
Terminal 15
none
none
10 ms/100 ms
none
CAN signal
none
E-gas fault / excessive acceleration / SK manager level 2 / CAN bus error / tuner plausibility
Malfunction potential strongly reduced on series, load dump is usually a collateral error from other faults, no repair option isolated for this fault
CC status report
none
Hard FGR load dump with lockout and CC message
0x2B5F
11103
Start lead CAS activation, electrical diagnosis
No Info.
No Info.
Driver diagnosis ATIC39
1000 ms
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
>1000 ms
none
Digital
N
Current too low/open control-activation wire/defective CAS
- Check plug and wiring harness to CAS
- Replace CAS
none
Engine fails to run
Possible start delay may be noticed
0x2B62
11106
Servotronic, converter current
No Info.
No Info.
Current through converter valve less than/equal to threshold K_SERVO_STROM_DIAG_OL although triggering with max. pulse-duty factor servo_tast == 100 %
20 ms
TERM87
Battery voltage > K_ED_UBMIN (9.0V)
none
>20 ms
none
Analog; 45--890mA PWM; servo_tast
N
Open wire leading to converter valve
- Check plug and wiring harness connected to converter valve
- Replace converter valve
- Clear fault memory
none
Converter must be under current, no tester triggering active, no test stand operation, error has not yet appeared in this driving cycle
Steers hard
0x2B63
11107
Servotronic, roadspeed signal
No Info.
No Info.
Error in front axle speed through CAN
none
B_ZUST_ML && B_V_VORNE_ERR
none
none
none
none
v servo
Y
Error in front axle speed through CAN
Check CAN communications with DSC
none
No test stand operation, no roller operation
Steering harder
0x2B5C
11100
Throttle valves fault status, bank 2
No Info.
No Info.
CAN implausible
200 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>200 ms
DK test routine
Analog; 0.2--4.8V
N
Defective CAN / contact resistance in plug connection or wiring harness
- Check wiring harness plug for throttle valve sensor DKG2
- Replace DKG2
EML, CC message, backup program
Pot comparison error present
CC message, Engine speed limited Reduced power
0x2B5E
11102
not translated
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2B62
11106
Servotronic, converter current
No Info.
No Info.
Current through converter valve above limit line i = f(Tast*Ub): servo_current > K_SERVO_STROM_DIAG_MAX_O FFSET + (servo_tast * ub * K_SERVO_DIAG_MAX_TAST/4096
20 ms
TERM87
Battery voltage > K_ED_UBMIN (9.0V)
none
>20 ms
none
Analog; 45--890mA PWM; servo_tast
N
Converter valve has shunt current to battery voltage
- Check plug and wiring harness connected to converter valve
- Replace converter valve
- Clear fault memory
none
Converter must be under current, no tester triggering active, no test stand operation, error has not yet appeared in this driving cycle
Steers hard
0x2B63
11107
Servotronic, roadspeed signal
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2B5C
11100
Throttle valves fault status, bank 2
Throttle Actuator
Throttle Stuck
egas_ist_dk_b2 > K EGAS SK DK OFFEN 1
200 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>200 ms
DK test routine
Analog; 0.2--4.8V
N
Valves open
- Check throttle valve assembly B2 for adjustment and friction
- Check wiring harness plug and power supply to throttle valve sensor DKG2
- Check installed position of throttle valve sensor DKG2
EML, CC message, backup program
Already in failsafe mode
CC message, Engine speed limited Reduced power
0x2B5C
11100
Throttle valves fault status, bank 2
Throttle Actuator
Throttle Stuck
egas_ist_dk_b1 > K EGAS SK DK OFFEN 2
200 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>200 ms
DK test routine
Analog; 0.2--4.8V
N
Valves open
- Check throttle valve assembly B2 for adjustment and friction
- Check wiring harness plug and power supply to throttle valve sensor DKG2
- Check installed position of throttle valve sensor DKG2
EML, CC message, backup program
Already in failsafe mode
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B16
11030
Throttle-valve actuator, governor monitoring, bank 2
Throttle Actuator
Power Stage
Actuator shifts to Failsafe mode
10 ms
TERM87
none
none
>10 ms
DK test routine
none
Y
Actuator shifts to Failsafe mode
- Clear fault memory, conduct EDR electronic throttle control system test
- Check plug and wiring harness at DKG2 and EDR2
- Replace DKG2 or EDR Bank 2
MIL, EML, CC message, backup program
Communications and CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B27
11047
Throttle valves, test of return springs, bank 1
Throttle Actuator
Spring Test
Time violation
20 ms
TERM87
none
none
>20 ms
DK test routine
none
Y
Fault in actuator
- Clear fault memory, EDR electronic throttle valve control system test
- Check throttle valve assembly for friction
- Replace EDR B1
MIL, EML, CC message, backup program
Tmot > -50 °C K_EGAS_STM_DK_FT_TMOT
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B27
11047
Throttle valves, test of return springs, bank 1
Throttle Actuator
Adaptation
Closing duration too low
20 ms
TERM87
none
none
>20 ms
DK test routine
none
Y
Defective springs / friction in throttle valve assembly
- Clear fault memory, EDR electronic throttle valve control system test
- Check throttle valve assembly for friction
- Replace EDR B1
MIL, EML, CC message, backup program
Tmot > -50 °C K_EGAS_STM_DK_FT_TMOT
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B15
11029
Throttle-valve actuator, governor monitoring, bank 1
Throttle Actuator
Power Stage
Actuator shifts to Failsafe mode
10 ms
TERM87
none
none
>10 ms
DK test routine
none
Y
Actuator shifts to Failsafe mode
- Clear fault memory, conduct EDR electronic throttle valve control system test
- Check plug and wiring harness at throttle valve sensor DKG1 and electronic throttle valve control EDR1
- Replace DKG1 or EDR for Bank 1
MIL, EML, CC message, backup program
Communications and CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B5B
11099
Throttle valves fault status, bank 1
Throttle Actuator
Position Control
Implausible WDK
200 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>200 ms
DK test routine
Analog; 0.2--4.8V
N
Defective DKG throttle valve sensor / Contact resistance in plug connection or wiring harness
- Check wiring harness plug for throttle valve sensor DKG1
- Replace throttle valve sensor DKG1
EML, CC message, backup program
Pot comparison error present
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B5B
11099
Throttle valves fault status, bank 1
No Info.
No Info.
CAN implausible
200 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>200 ms
DK test routine
Analog; 0.2--4.8V
N
Defective CAN / contact resistance in plug connection or wiring harness
- Check wiring harness plug for throttle valve sensor DKG1
- Replace throttle valve sensor DKG1
EML, CC message, backup program
Pot comparison error present
CC message, Engine speed limited Reduced power
0x2B5B
11099
Throttle valves fault status, bank 1
Throttle Actuator
Throttle Stuck
egas_ist_dk_b2 > K EGAS SK DK OFFEN 1
200 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>200 ms
DK test routine
Analog; 0.2--4.8V
N
Valves open / friction in throttle-valve assembly / defective EDR electronic throttle valve control / defective DKG throttle valve sensor
- Check throttle valve assembly B1 for adjustment and friction
- Check wiring harness plug and power supply to EDR B1 and DKG1
- Check installed position of DKG1
EML, CC message, backup program
Already in failsafe mode
CC message, Engine speed limited Reduced power
0x2B5B
11099
Throttle valves fault status, bank 1
Throttle Actuator
Throttle Stuck
egas_ist_dk_b1 > K EGAS SK DK OFFEN 2
200 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>200 ms
DK test routine
Analog; 0.2--4.8V
N
Valves open / friction in throttle-valve assembly / defective EDR electronic throttle valve control / defective DKG throttle valve sensor
- Check throttle valve assembly B1 for adjustment and friction
- Check wiring harness plug and power supply to EDR B1 and DKG1
- Check installed position of DKG1
EML, CC message, backup program
Already in failsafe mode
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x27A8
10152
Control module, internal fault
No Info.
No Info.
Implausible data
100 ms
Terminal 15
none
none
>100 ms
none
none
Y
Test calculation incorrect or timeout Complementary comparison false
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x27A8
10152
Control module, internal fault
Throttle Control Monitor Level 2/3
RPM
POS_DELTA(n, n_proz) > K N E2 DELTA
10 ms/100 ms
none
none
none
>100 ms
none
none
Y
Various sensor errors (e.g., n)
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
none
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B55
11093
Control module, internal fault
Throttle Control Monitor Level 2/3
RPM
ECU internal RPM deviation of K_N_E2_DELTA for a period of K_N_E2_T_MAX
10 ms/100 ms
Terminal 15
none
none
>100 ms
none
none
Y
Various sensor errors (e.g., n)
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
No malfunction in crankshaft position monitoring
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x27A8
10152
Control module, internal fault
Throttle Control Monitor Level 2/3
Clutch Torque
Implausible data
10 ms/100 ms
Terminal 15
none
none
>100 ms
none
none
Y
Accessing error
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
none
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x27A8
10152
Control module, internal fault
Throttle Control Monitor Level 2/3
Clutch Torque
Implausible data
100 ms
Terminal 15
none
none
>100 ms
none
none
Y
Test calculation incorrect or timeout Complementary comparison false
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
Processor communications OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x27A8
10152
Control module, internal fault
Throttle Control Monitor Level 2/3
Pedal Position Sensor
POS_DELTA(n, n_proz) > K N E2 DELTA
10 ms/100 ms
none
none
none
>100 ms
none
none
Y
Various sensor errors (e.g., n)
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
none
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x27A8
10152
Control module, internal fault
Throttle Control Monitor Level 2/3
Torque
(n_begr_ti > K_N_BEGR_TI_MAX_E2) or (n_e2 > n_max) and injection active
10 ms/100 ms
none
none
none
>100 ms
none
none
Y
RPM governing not OK
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
none
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B55
11093
Control module, internal fault
Throttle Control Monitor Level 2/3
Torque
Deviations too large (KF_MD_KUPP_OFF_E2, K_MD_E2_IST_SCHW, ...)
10 ms/100 ms
Terminal 15
none
none
>10/100ms
none
none
Y
Monitoring Torque monitor
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
Level 1 OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x27A8
10152
Control module, internal fault
Throttle Control Monitor Level 2/3
RPM
Implausible data
10 ms/100 ms
Terminal 15
none
none
>100 ms
none
none
Y
Accessing error
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
none
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B55
11093
Control module, internal fault
Throttle Control Monitor Level 2/3
RPM
Implausible data
10 ms/100 ms
Terminal 15
none
none
>10/100ms
none
none
Y
Access error (SMG, DSC)
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
Level 1 OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B2A
11050
Idle actuator initialization
No Info.
No Info.
Same bank index
500 ms
TERM87
none
none
>500 ms.
LLS test routine
none
Y
Both actuators share the same bank assignment
- Check plugs and wiring harness on both LLS (special Ident wire)
- Replace EDR B1 or B2 as indicated
EML, CC message, backup program
Communications and CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B2A
11050
Idle actuator initialization
No Info.
No Info.
Different versions
500 ms
TERM87
none
none
>500 ms.
LLS test routine
none
Y
Different versions
- Carry out LLS idle actuator system diagnosis
- Check plug and wiring harness on LLS B1 and B2
- Check plug and wiring harness on DME, particularly throttle valve DK CAN wire Pin 5--21 and 5--43 on
- Replace EDR B1 or B2
EML, CC message, backup program
Communications and CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B29
11049
Moment manager monitoring
ECM Self-Test
Idle Speed Control
I-component greater than K_MD_SK_LLR_MAX
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Specified value too high
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
Engine running
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B55
11093
Control module, internal fault
No Info.
No Info.
Implausible data
10 ms/100 ms
Terminal 15
none
none
>10/100ms
none
none
Y
Access error (SMG, DSC)
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
Level 1 OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B29
11049
Moment manager monitoring
ECM Self-Test
Clutch Torque
Specified torques greater than K_MD_SK_IND_MAX
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Ind. specified torque, specified charge factor or min. ETA implausible
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
Engine running
CC message Engine speed limited Reduced power MIL after engine runs 2x
0x2B29
11049
Moment manager monitoring
ECM Self-Test
Clutch Torque
Minimum torque exceeds K_MD_SK_MAX_MDMIN
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Minimum torque too high
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
RPM greater than K_MD_SK_N_MDMIN and starting torque dissipated
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B29
11049
Moment manager monitoring
ECM Self-Test
Engine Torque
Difference too large
500 ms
Terminal 15
none
none
>500 ms.
none
none
Y
Comparison of specified and actual torque
- Check load monitoring
- Clear fault memory
- Update DME
- Replace DME
MIL, EML, CC message, backup program
Engine running
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x278D
10125
Alternator, communication
No Info.
No Info.
b_genfkupl_ak = True && b_upltomin = False
2500 ms
TERM87
none
none
>2500 ms
none
Digital - BSD bus
N
Implausible alternator version
Install correct alternator version
none
Error is not logged; instead in F.ort 1_139 (hard coded)
Driver does not notice.
0x27DF
10207
Tank sensor, left, electrical fault
Fuel Level Sensor
Electrical
Error designation posted on CAN
K_FST_CAN_FEHLER = 120s
Terminal 15
none
none
>120 sec.
none
Fuel level sensor CAN signal, monitoring in I-cluster
N
Electrical malfunction in left-side fuel level sensor
Read out fault memories logged in I-cluster, check fuel level sensor including wiring
MIL
No CAN timeout (PT_KMST_FEHLER), No CAN timeout (PT_OBD_ED_FEHLER)
Defective fuel level display in I-cluster
0x27DF
10207
Tank sensor, left, electrical fault
Fuel Level Sensor
Electrical
Error designation posted on CAN
K_FST_CAN_FEHLER = 120s
Terminal 15
none
none
>120 sec.
none
Fuel level sensor CAN signal, monitoring in I-cluster
N
Electrical malfunction in left-side fuel level sensor
Read out fault memories logged in I-cluster, check fuel level sensor including wiring
MIL
No CAN timeout (PT_KMST_FEHLER), No CAN timeout (PT_OBD_ED_FEHLER)
Defective fuel level display in I-cluster
0x27DF
10207
Tank sensor, left, electrical fault
Fuel Level Sensor
Electrical
Error designation posted on CAN
K_FST_CAN_FEHLER = 120s
Terminal 15
none
none
>120 sec.
none
Fuel level sensor CAN signal, monitoring in I-cluster
N
Electrical malfunction in left-side fuel level sensor
Read out fault memories logged in I-cluster, check fuel level sensor including wiring
MIL
No CAN timeout (PT_KMST_FEHLER), No CAN timeout (PT_OBD_ED_FEHLER)
Defective fuel level display in I-cluster
0x27DF
10207
Tank sensor, left, electrical fault
Fuel Level Sensor
Electrical
Error designation posted on CAN
K_FST_CAN_FEHLER = 120s
Terminal 15
none
none
>120 sec.
none
Fuel level sensor CAN signal, monitoring in I-cluster
N
Electrical malfunction in left-side fuel level sensor
Read out fault memories logged in I-cluster, check fuel level sensor including wiring
MIL
No CAN timeout (PT_KMST_FEHLER), No CAN timeout (PT_OBD_ED_FEHLER)
Defective fuel level display in I-cluster
0x2763
10083
VANOS valve, inlet, bank 1, activation
Camshaft Position Actuator
Intake
Driver diagnosis ATIC35 (Current too high with valve on)
Errors recognized 10x consecutively
TERM87
Battery voltage > 10V (k_diag_tr_ed_ubmin)
none
roughly 1 sec. with closed-loop control active
VANOS
Internal driver diagnosis
N
Activation wire shorted to ground
- Check plug and wiring harness to VANOS EV B1
- Check valve and replace as indicated
MIL
Valve triggered
Reduced torque / worse exhaust emissions / MIL on after engine runs 2x
0x2763
10083
VANOS valve, inlet, bank 1, activation
Camshaft Position Actuator
Intake
Driver diagnosis ATIC35 (Voltage too high with valve off)
Errors recognized 10x consecutively
TERM87
Battery voltage > 10V (k_diag_tr_ed_ubmin)
none
roughly 1 sec. with closed-loop control active
VANOS
Internal driver diagnosis
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness to VANOS EV B1
- Check valve and replace as indicated
MIL
none
Reduced torque / worse exhaust emissions / MIL on after engine runs 2x
0x2764
10084
VANOS valve, exhaust, bank 1, activation
Camshaft Position Actuator
Exhaust
Driver diagnosis ATIC35 (Current too high with valve on)
Errors recognized 10x consecutively
TERM87
Battery voltage > 10V (k_diag_tr_ed_ubmin)
none
roughly 1 sec. with closed-loop control active
VANOS
Internal driver diagnosis
N
Activation wire shorted to ground
- Check plug and wiring harness to VANOS AV B1
- Check valve and replace as indicated
MIL
Valve triggered
Reduced torque / worse exhaust emissions / MIL on after engine runs 2x
0x2764
10084
VANOS valve, exhaust, bank 1, activation
Camshaft Position Actuator
Exhaust
Driver diagnosis ATIC35 (Voltage too high with valve off)
Errors recognized 10x consecutively
TERM87
Battery voltage > 10V (k_diag_tr_ed_ubmin)
none
roughly 1 sec. with closed-loop control active
VANOS
Internal driver diagnosis
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness to VANOS AV B1
- Check valve and replace as indicated
MIL
none
Reduced torque / worse exhaust emissions / MIL on after engine runs 2x
0x2765
10085
VANOS valve, inlet, bank 2, activation
Camshaft Position Actuator
Intake
Driver diagnosis ATIC35 (Current too high with valve on)
Errors recognized 10x consecutively
TERM87
Battery voltage > 10V (k_diag_tr_ed_ubmin)
none
roughly 1 sec. with closed-loop control active
VANOS
Internal driver diagnosis
N
Activation wire shorted to ground
- Check plug and wiring harness to VANOS EV B1
- Check valve and replace as indicated
MIL
Valve triggered
Reduced torque / worse exhaust emissions / MIL on after engine runs 2x
0x2765
10085
VANOS valve, inlet, bank 2, activation
Camshaft Position Actuator
Intake
Driver diagnosis ATIC35 (Voltage too high with valve off)
Errors recognized 10x consecutively
TERM87
Battery voltage > 10V (k_diag_tr_ed_ubmin)
none
roughly 1 sec. with closed-loop control active
VANOS
Internal driver diagnosis
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness to VANOS EV B1
- Check valve and replace as indicated
MIL
none
Reduced torque / worse exhaust emissions / MIL on after engine runs 2x
0x2766
10086
VANOS valve, exhaust, bank 2, activation
Camshaft Position Actuator
Exhaust
Driver diagnosis ATIC35 (Current too high with valve on)
Errors recognized 10x consecutively
TERM87
Battery voltage > 10V (k_diag_tr_ed_ubmin)
none
roughly 1 sec. with closed-loop control active
VANOS
Internal driver diagnosis
N
Activation wire shorted to ground / defective valve
- Check plug and wiring harness to VANOS EV B2
- Check valve and replace as indicated
MIL
Valve triggered
Reduced torque / worse exhaust emissions / MIL on after engine runs 2x
0x2766
10086
VANOS valve, exhaust, bank 2, activation
Camshaft Position Actuator
Exhaust
Driver diagnosis ATIC35 (Voltage too high with valve off)
Errors recognized 10x consecutively
TERM87
Battery voltage > 10V (k_diag_tr_ed_ubmin)
none
roughly 1 sec. with closed-loop control active
VANOS
Internal driver diagnosis
N
Activation wire shorted to battery voltage / defective valve
- Check plug and wiring harness to VANOS EV B2
- Check valve and replace as indicated
MIL
none
Reduced torque / worse exhaust emissions / MIL on after engine runs 2x
0x27C6
10182
Oxygen sensor, adaptation, trim control, bank 1
Fuel System
Post Catalyst
Adaptation value reaches MIN limit and hangs in this position
Counter for recognition at adaptation limit >= (2x) K_LA_TRIM_DIAG_I_AD_MAX_SCHW
Engine running
none
none
?
none
none
Y
Detecting a leak in the fuel system
- Check the fuel system and the exhaust system for leaks
- Check pre-cat and post-cat sensors and replace as indicated
MIL
Trim control must be active; I-component determination must be completed and the data adopted in the AD value
MIL on after engine runs 2x
0x277C
10108
Oxygen sensor trim control diagnosis, bank 1
Fuel System
Post Catalyst
RICH suspected when I-component is considered (K_LA_TRIM_DIAG_I_MAX_SCHW recognition of I-component limit) leads to targeted RICH/LEAN control activation; if pre-cat and post-cat sensors react accordingly, a trim control error is recognized.
No Info.
Engine running
none
none
No Info.
none
Analog
Y
Detecting a leak in the fuel system
1) Check intake and exhaust systems for leaks; incl. HFM operation/ ..if no fault is present.. 2.) Conduct oxygen sensor test routine/ 3.) If the test does not produce any results and the trim control error is still present ->Replace the sensor before the catalytic converter
MIL
Active trim control (steady-state operation between 2000 and 3000 RPM in part-load range. ... min. 120 sec.) and I-component determination must have taken place
MIL on after engine runs 2x / no effects on driveability
0x27C6
10182
Oxygen sensor, adaptation, trim control, bank 1
Fuel System
Post Catalyst
Adaptation value reaches max. limit and hangs in this position
Counter for recognition at adaptation limit >= (2x) K_LA_TRIM_DIAG_I_AD_MAX_SCHW
Engine running
none
none
?
none
none
Y
Detecting a leak in the fuel system
- Check the fuel system and the exhaust system for leaks
- Check pre-cat and post-cat sensors and replace as indicated
MIL
Trim control must be active; I-component determination must be completed and the data adopted in the AD value
MIL on after engine runs 2x
0x277C
10108
Oxygen sensor trim control diagnosis, bank 1
Fuel System
Post Catalyst
LEAN suspected when I-component is considered (K_LA_TRIM_DIAG_I_MIN_SCHW recognition of I-component at limit) leads to targeted RICH/LEAN control activation; if pre-cat and post-cat sensors react accordingly, a trim control error is recognized.
No Info.
Engine running
none
none
No Info.
none
Analog
Y
Detecting a leak in the fuel system
1) Check intake and exhaust systems for leaks; incl. HFM operation/ ..if no fault is present.. 2.) Conduct oxygen sensor test routine/ 3.) If the test does not produce any results and the trim control error is still present ->Replace the sensor before the catalytic converter
MIL
Active trim control (steady-state operation between 2000 and 3000 RPM in part-load range. ... min. 120 sec.) and I-component determination must have taken place
MIL on after engine runs 2x / no effects on driveability
0x2781
10113
TD signal, activation, electrical diagnosis
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x277E
10110
Main relay, activation, electrical diagnosis
No Info.
No Info.
Driver diagnosis
1000 ms
none
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
>1000 ms
none
Digital
N
Voltage too low on the main relay activation wire
- Check plug and wiring harness at main relay
- Replace main relay
none
none
Possible CC message, High battery discharge rate when parked.
0x2781
10113
TD signal, activation, electrical diagnosis
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x27C7
10183
Oxygen sensor, adaptation, trim control, bank 2
Fuel System
Post Catalyst
Adaptation value reaches MIN limit and hangs in this position
Counter for recognition at adaptation limit >= (2x) K_LA_TRIM_DIAG_I_AD_MAX_SCHW
Engine running
none
none
?
none
none
Y
Detecting a leak in the fuel system
- Check the fuel system and the exhaust system for leaks
- Check pre-cat and post-cat sensors and replace as indicated
MIL
Trim control must be active; I-component determination must be completed and the data adopted in the AD value
MIL on after engine runs 2x
0x2780
10112
No coding
No Info.
No Info.
Encoding violates process parameters
20000 ms
none
none
none
>20000 ms
none
none
N
Control module not encoded
Encode ECU
none
none
Possible, under some conditions no correct M Drive functionality
0x2781
10113
TD signal, activation, electrical diagnosis
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x277D
10109
Oxygen sensor trim control diagnosis, bank 2
Fuel System
Post Catalyst
RICH suspected when I-component is considered (K_LA_TRIM_DIAG_I_MAX_SCHW recognition of I-component limit) leads to targeted RICH/LEAN control activation; if pre-cat and post-cat sensors react accordingly, a trim control error is recognized.
No Info.
Engine running
none
none
No Info.
none
Analog
Y
Detecting a leak in the fuel system
1) Check intake and exhaust systems for leaks; incl. HFM operation/ ..if no fault is present.. 2.) Conduct oxygen sensor test routine/ 3.) If the test does not produce any results and the trim control error is still present ->Replace the sensor before the catalytic converter
MIL
Active trim control (steady-state operation between 2000 and 3000 RPM in part-load range. ... min. 120 sec.) and I-component determination must have taken place
MIL on after engine runs 2x / no effects on driveability
0x2780
10112
No coding
No Info.
No Info.
Not possible to encode owing to memory
20000 ms
none
none
none
>20000 ms
none
none
N
No sector available for encoding
Wait for ECU shutdown phase, encode ECU
none
none
Possible, under some conditions no correct M Drive functionality
0x2781
10113
TD signal, activation, electrical diagnosis
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x27C7
10183
Oxygen sensor, adaptation, trim control, bank 2
Fuel System
Post Catalyst
Adaptation value reaches max. limit and hangs in this position
Counter for recognition at adaptation limit >= (2x) K_LA_TRIM_DIAG_I_AD_MAX_SCHW
Engine running
none
none
?
none
none
Y
Detecting a leak in the fuel system
- Check the fuel system and the exhaust system for leaks
- Check pre-cat and post-cat sensors and replace as indicated
MIL
Trim control must be active; I-component determination must be completed and the data adopted in the AD value
MIL on after engine runs 2x
0x277D
10109
Oxygen sensor trim control diagnosis, bank 2
Fuel System
Post Catalyst
LEAN suspected when I-component is considered (K_LA_TRIM_DIAG_I_MIN_SCHW recognition of I-component at limit) leads to targeted RICH/LEAN control activation; if pre-cat and post-cat sensors react accordingly, a trim control error is recognized.
No Info.
Engine running
none
none
No Info.
none
Analog
Y
Detecting a leak in the fuel system
1) Check intake and exhaust systems for leaks; incl. HFM operation/ ..if no fault is present.. 2.) Conduct oxygen sensor test routine/ 3.) If the test does not produce any results and the trim control error is still present ->Replace the sensor before the catalytic converter
MIL
Active trim control (steady-state operation between 2000 and 3000 RPM in part-load range. ... min. 120 sec.) and I-component determination must have taken place
MIL on after engine runs 2x / no effects on driveability
0x2B15
11029
Throttle-valve actuator, governor monitoring, bank 1
Throttle Actuator
Control Motor
Actuator shifts to Failsafe mode
10 ms
TERM87
none
none
>10 ms
DK test routine
none
Y
Actuator shifts to Failsafe mode
- Clear fault memory, conduct EDR electronic throttle valve control system test
- Check plug and wiring harness at throttle valve sensor DKG1 and electronic throttle valve control EDR1
- Replace DKG1 or EDR for Bank 1
MIL, EML, CC message, backup program
Communications and CAN OK
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B05
11013
Pedal-position sensor 1
Pedal Position Sensor
D Electrical
Measured value <= K_PWG1_DIAG_MIN
100 ms
none
none
none
100 ms
none
analog
N
Measured value too low / signal wire shorted to ground or open wire / defective PWG pedal travel sensor
- Check plug and wiring harness on PWG pedal travel sensor and at DME
- Replace accelerator pedal module
MIL, EML, CC message, backup program
No errors + Terminal 15 off => Terminate emergency program
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B05
11013
Pedal-position sensor 1
Pedal Position Sensor
D Electrical
Measured value >= K_PWG1_DIAG_MAX
100 ms
none
none
none
100 ms
none
analog
N
Measured value too high / signal wire shorted to positive / defective PWG pedal travel sensor
- Check plug and wiring harness on PWG pedal travel sensor and at DME
- Replace accelerator pedal module
MIL, EML, CC message, backup program
No errors + Terminal 15 off => Terminate emergency program
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B06
11014
Pedal-position sensor 2
Pedal Position Sensor
E Electrical
Measured value <= K_PWG1_DIAG_MIN: 2
100 ms
none
none
none
100 ms
none
analog
N
Measured value too low / signal wire shorted to ground or open wire / defective PWG pedal travel sensor
- Check plug and wiring harness on PWG pedal travel sensor and at DME
- Replace accelerator pedal module
MIL, EML, CC message, backup program
No errors + Terminal 15 off => Terminate emergency program
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B06
11014
Pedal-position sensor 2
Pedal Position Sensor
E Electrical
Measured value >= K_PWG1_DIAG_MAX: 2
100 ms
none
none
none
100 ms
none
analog
N
Measured value too high / signal wire shorted to positive / defective PWG pedal travel sensor
- Check plug and wiring harness on PWG pedal travel sensor and at DME
- Replace accelerator pedal module
MIL, EML, CC message, backup program
No errors + Terminal 15 off => Terminate emergency program
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2B07
11015
Pedal-position sensor, plausibility
Pedal Position Sensor
D/E Correlation
PWG1 > PWG2 + KL_PWG_MAX_DIFF
250 ms
none
none
none
250 ms
none
analog
N
Measured value for PWG1 pedal travel sensor greater than measured value for PWG2 / contact resistance in plug connections / defective sensor
- Check plug and wiring harness on PWG pedal travel sensor and at DME
- Replace accelerator pedal module
MIL, EML, CC message, backup program
No errors + Terminal 15 off => Terminate emergency program
CC message, Engine speed limited Reduced power
0x2B07
11015
Pedal-position sensor, plausibility
Pedal Position Sensor
D/E Correlation
PWG2 > PWG1 + KL_PWG_MAX_DIFF
250 ms
none
none
none
250 ms
none
analog
N
Measured value for PWG2 pedal travel sensor greater than measured value for PWG1 / contact resistance in plug connections / defective sensor
- Check plug and wiring harness on PWG pedal travel sensor and at DME
- Replace accelerator pedal module
MIL, EML, CC message, backup program
No errors + Terminal 15 off => Terminate emergency program
CC message, Engine speed limited Reduced power
0x27BA
10170
Fuel system, lambda/charge plausibility, bank 1
Fuel System
Off Idle
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM_DELTA_ML_MAX
K_FPLAU_LAM_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
Tmot > 69 °C (K_FPLAU_OBD_TMOT_WARM)
>10 sec.
none
Digital
Y
Detecting a leak in the fuel system
- Check the fuel system for leaks/
- System test routine /
- HFM and charge path must be flawless./
- Defective fuel pressure sensor
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x27BA
10170
Fuel system, lambda/charge plausibility, bank 1
Fuel System
Off Idle
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM_DELTA_ML_MAX * expansion factor (KL_FPLAU_OBD_LAM_CSS_F)
K_FPLAU_LAM_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
18 °C < tmot < 68 °C (K_FPLAU_OBD_TMOT_CSS_MIN; K_FPLAU_OBD_TMOT_CSS_MAX)
>10 sec.
none
Digital
Y
Detecting a leak in the fuel system
- Check the fuel system for leaks/
- System test routine /
- HFM and charge path must be flawless./
- Defective fuel pressure sensor
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x27BA
10170
Fuel system, lambda/charge plausibility, bank 1
Fuel System
Off Idle
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM_DELTA_ML_MAX
K_FPLAU_LAM_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
Tmot > 69 °C (K_FPLAU_OBD_TMOT_WARM)
>10 sec.
none
Digital
Y
Detecting a leak in the fuel system
- Check the fuel system for leaks/
- System test routine /
- HFM and charge path must be flawless./
- Defective fuel pressure sensor
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x27BA
10170
Fuel system, lambda/charge plausibility, bank 1
Fuel System
Off Idle
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM_DELTA_ML_MAX * expansion factor (KL_FPLAU_OBD_LAM_CSS_F)
K_FPLAU_LAM_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
18 °C < tmot < 68 °C (K_FPLAU_OBD_TMOT_CSS_MIN; K_FPLAU_OBD_TMOT_CSS_MAX)
>10 sec.
none
Digital
Y
Detecting a leak in the fuel system
- Check the fuel system for leaks/
- System test routine /
- HFM and charge path must be flawless./
- Defective fuel pressure sensor
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x27BB
10171
Fuel system, lambda/charge plausibility, bank 2
Fuel System
Off Idle
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM_DELTA_ML_MAX
K_FPLAU_LAM_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
Tmot > 69 °C (K_FPLAU_OBD_TMOT_WARM)
>10 sec.
none
Digital
Y
Detecting a leak in the fuel system
- Check the fuel system for leaks/
- System test routine /
- HFM and charge path must be flawless./
- Defective fuel pressure sensor
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x27C1
10177
Info: Tank empty on fault entry
No Info.
No Info.
Error codes logged that could be traceable to lack of fuel
none
none
none
none
none
none
Fault memory entry related to empty tank
Y
No error, but supplementary information for other fault memory entry
Repair primary malfunction
none
As supplementary information for error code entries that could be caused by lack of fuel
none
0x27C1
10177
Info: Tank empty on fault entry
No Info.
No Info.
Error codes logged that could be traceable to lack of fuel
none
none
none
none
none
none
Fault memory entry related to empty tank
Y
No error, but supplementary information for other fault memory entry
Repair primary malfunction
none
As supplementary information for error code entries that could be caused by lack of fuel
none
0x27BB
10171
Fuel system, lambda/charge plausibility, bank 2
Fuel System
Off Idle
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM_DELTA_ML_MAX * expansion factor (KL_FPLAU_OBD_LAM_CSS_F)
K_FPLAU_LAM_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
18 °C < tmot < 68 °C (K_FPLAU_OBD_TMOT_CSS_MIN; K_FPLAU_OBD_TMOT_CSS_MAX)
>10 sec.
none
Digital
Y
Detecting a leak in the fuel system
- Check the fuel system for leaks/
- System test routine /
- HFM and charge path must be flawless./
- Defective fuel pressure sensor
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x27BC
10172
Cat. protection, bank 1
No Info.
No Info.
Cold temperature > K_KATS_TKAT_MESS_MAX in the period K_KATS_T_LAM_MIN
CAT temperature exceeds K_KATS_TKAT_MESS_MAX (1000 °C) for K_KATS_T_LAM_MIN (2s)
Engine running
none
none
> 1000 sec. (varies according to accompanying conditions)
none
none
Y
Catalyst temperature too high Invalid engine operation or engine malfunction (fuel trim)
- Conduct secondary air pump test routine
- Conduct fuel system test routine
- Check exhaust system for leaks
EML, CC message, backup program
none
CC message, Engine speed limited Reduced power
0x27BD
10173
Cat. protection, bank 2
No Info.
No Info.
Cold temperature > K_KATS_TKAT_MESS_MAX in the period K_KATS_T_LAM_MIN
CAT temperature exceeds K_KATS_TKAT_MESS_MAX (1000 °C) for K_KATS_T_LAM_MIN (2s)
Engine running
none
none
> 1000 sec. (varies according to accompanying conditions)
none
none
Y
Catalyst temperature too high Invalid engine operation or engine malfunction (fuel trim)
- Conduct secondary air pump test routine
- Conduct fuel system test routine
- Check exhaust system for leaks
EML, CC message, backup program
none
CC message, Engine speed limited Reduced power
0x27C1
10177
Info: Tank empty on fault entry
No Info.
No Info.
Error codes logged that could be traceable to lack of fuel
none
none
none
none
none
none
Fault memory entry related to incorrect fuel level
Y
No error, but supplementary information for other fault memory entry
Repair level sensor fault as well as primary malfunction
none
As supplementary information for error code entries that could be caused by lack of fuel
none
0x27BB
10171
Fuel system, lambda/charge plausibility, bank 2
Fuel System
Off Idle
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM_DELTA_ML_MAX
K_FPLAU_LAM_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
Tmot > 69 °C (K_FPLAU_OBD_TMOT_WARM)
>10 sec.
none
Digital
Y
Detecting a leak in the fuel system
- Check the fuel system for leaks/
- System test routine /
- HFM and charge path must be flawless./
- Defective fuel pressure sensor
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x27BB
10171
Fuel system, lambda/charge plausibility, bank 2
Fuel System
Off Idle
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM_DELTA_ML_MAX * expansion factor (KL_FPLAU_OBD_LAM_CSS_F)
K_FPLAU_LAM_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
18 °C < tmot < 68 °C (K_FPLAU_OBD_TMOT_CSS_MIN; K_FPLAU_OBD_TMOT_CSS_MAX)
>10 sec.
none
Digital
Y
Detecting a leak in the fuel system
- Check the fuel system for leaks/
- System test routine /
- HFM and charge path must be flawless./
- Defective fuel pressure sensor
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x2737
10039
Charge plausibility, diagnosis, cold-start strategy, bank 1
Fuel System
Higher Load
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM/AQ_DELTA _ML_MAX * expansion factors (K_FPLAU_OBD_TE_F, KL_FPLAU_OBD_AQ_PSAU_CSS_F)
K_FPLAU_LAM/AQ_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
18 °C < tmot68 °C (K_FPLAU_OBD_TMOT_CSS_MIN; K_FPLAU_OBD_TMOT_CSS_MAX)
>10 sec.
none
Digital
Y
Charge factor calculation from AQ is not plausible or incorrect fuel trim
- Check induction system B1 for leaks
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x27AA
10154
Charge plausibility, diagnosis hot - bank 1
Fuel System
Higher Load
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_AQ_DELTA_ML_MAX * expansion factor (K_FPLAU_OBD_TE_F)
K_FPLAU_LAM/AQ_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
Tmot > 69 °C (K_FPLAU_OBD_TMOT_WARM)
>10 sec.
none
none
Y
Charge factor calculation from AQ is not plausible or incorrect fuel trim
- Check induction system B1 for leaks
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x2738
10040
Charge plausibility, diagnosis, cold-start strategy, bank 2
Fuel System
Higher Load
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM/AQ_DELTA _ML_MAX * expansion factors (K_FPLAU_OBD_TE_F, KL_FPLAU_OBD_AQ_PSAU_CSS_F)
K_FPLAU_LAM/AQ_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
18 °C < tmot < 68 °C (K_FPLAU_OBD_TMOT_CSS_MIN; K_FPLAU_OBD_TMOT_CSS_MAX)
>10 sec.
none
Digital
Y
Charge factor calculation from AQ is not plausible or incorrect fuel trim
- Check induction system B1 for leaks
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x27AB
10155
Charge plausibility, diagnosis hot - bank 2
Fuel System
Higher Load
Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to RPM/load factor) KF_FPLAU_OBD_LAM_DELTA_ML_MAX * expansion factors (K_FPLAU_OBD_TE_F)
K_FPLAU_LAM/AQ_OBD_CNT * K_FPLAU_OBD_T_MAX (15 sec.)
Engine running
none
Tmot > 69 °C (K_FPLAU_OBD_TMOT_WARM)
>1500 ms
none
none
Y
Charge factor calculation from AQ is not plausible or incorrect fuel trim
- Check induction system B1 for leaks
MIL
* Engine running, no dynamic response * Engine running for 10 sec. (K_FPLAU_OBD_T_MIN) * K_FPLAU_OBD_N_MIN < Engine speed < K_FPLAU_OBD_N_MAX * No error - lamda control, WDK, DK, LLS, VANOS, PUMG, TAN) * Pre-cat oxygen sensor is available
MIL on after engine runs 2x
0x2726
10022
Oxygen sensor, plausibility before cat., bank 1
Oxygen Sensor, Front
Signal Check
Oxygen sensor voltage behind catalytic converter <= 88mV (K_LAVK_OBD_PLAU_LANK_MIN) (lean) and lamda value before catalytic converter <= 0.92 (K_LAVK_OBD_PLAU_LAM_FETT) (rich) for a number of 1 (K_LAVK_OBD_PLAU_F_CNT) following a lag period before function start of 10 sec. (K_LAVK_OBD_PLAU_T)
100 ms
Engine running - Condition idle or part-load
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) 150 °C < tkat < 950 °C (K_LAVK_OBD_PLAU_TKAT_MAX; K_LAVK_OBD_PLAU_TKAT_MIN)
>100 ms, after the entire system has stabilized (lag roughly 18 sec.)
none
Digital
Y
Lamda value is too LEAN / Mixture pilot control implausible / Correlation of signals from sensor before catalytic converter to sensor behind catalytic converter is implausible
- Clear fault memory, oxygen sensor system test
- Check plug and wiring harness to pre-cat oxygen sensor LSVK B1
- Check induction system and exhaust system for leaks
- Replace oxygen sensor
MIL
* relative charge within the limits K_LAVK_OBD_PLAU_RF_MAX and K_LAVK_OBD_PLAU_RF_MIN; no dynamic response
MIL on after engine runs 2x
0x2726
10022
Oxygen sensor, plausibility before cat., bank 1
Oxygen Sensor, Front
Signal Check
Oxygen sensor voltage behind catalytic converter >= 879 mV (K_LAVK_OBD_PLAU_LANK_MAX ) (rich) and lamda value before catalytic converter >= 1.08 (K_LAVK_OBD_PLAU_LAM_MAGE R) (lean) for a number of 1 (K_LAVK_OBD_PLAU_M_CNT) after a lag period before function star of 10 sec. (K_LAVK_OBD_PLAU_T)
100 ms
Engine running - Condition idle or part-load
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) 150 °C < tkat < 950 °C (K_LAVK_OBD_PLAU_TKAT_MAX; K_LAVK_OBD_PLAU_TKAT_MIN)
>100 ms, after the entire system has stabilized (lag roughly 18 sec.)
none
Digital
Y
Lamda value is too RICH / Mixture pilot control implausible / Correlation of signals from sensor before catalytic converter to sensor behind catalytic converter is implausible
- Clear fault memory, oxygen sensor system test
- Check plug and wiring harness to pre-cat oxygen sensor LSVK B1
- Check induction system and exhaust system for leaks
- Replace oxygen sensor
MIL
* relative charge within the limits K_LAVK_OBD_PLAU_RF_MAX and K_LAVK_OBD_PLAU_RF_MIN; no dynamic response
MIL on after engine runs 2x
0x2727
10023
Oxygen sensor, plausibility before cat., bank 2
Oxygen Sensor, Front
Signal Check
Oxygen sensor voltage behind catalytic converter <= 88mV (K_LAVK_OBD_PLAU_LANK_MIN) (lean) and lamda value before catalytic converter <= 0.92 (K_LAVK_OBD_PLAU_LAM_FETT) (rich) for a number of 1 (K_LAVK_OBD_PLAU_F_CNT) following a lag period before function start of 10 sec. (K_LAVK_OBD_PLAU_T)
100 ms
Engine running - Condition idle or part-load
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) 150 °C < tkat < 950 °C (K_LAVK_OBD_PLAU_TKAT_MAX; K_LAVK_OBD_PLAU_TKAT_MIN)
>100 ms, after the entire system has stabilized (lag roughly 18 sec.)
none
Digital
Y
Lamda value is too LEAN / Mixture pilot control implausible / Correlation of signals from sensor before catalytic converter to sensor behind catalytic converter is implausible
- Clear fault memory, oxygen sensor system test
- Check plug and wiring harness to pre-cat oxygen sensor LSVK B2
- Check induction system and exhaust system for leaks
- Replace oxygen sensor
MIL
* relative charge within the limits K_LAVK_OBD_PLAU_RF_MAX and K_LAVK_OBD_PLAU_RF_MIN; no dynamic response
MIL on after engine runs 2x
0x2727
10023
Oxygen sensor, plausibility before cat., bank 2
Oxygen Sensor, Front
Signal Check
Oxygen sensor voltage behind catalytic converter >= 879 mV (K_LAVK_OBD_PLAU_LANK_MAX ) (rich) and lamda value before catalytic converter >= 1.08 (K_LAVK_OBD_PLAU_LAM_MAGE R) (lean) for a number of 1 (K_LAVK_OBD_PLAU_M_CNT) after a lag period before function star of 10 sec. (K_LAVK_OBD_PLAU_T)
100 ms
Engine running - Condition idle or part-load
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) 150 °C < tkat < 950 °C (K_LAVK_OBD_PLAU_TKAT_MAX; K_LAVK_OBD_PLAU_TKAT_MIN)
>100 ms, after the entire system has stabilized (lag roughly 18 sec.)
none
Digital
Y
Lamda value is too RICH / Mixture pilot control implausible / Correlation of signals from sensor before catalytic converter to sensor behind catalytic converter is implausible
- Clear fault memory, oxygen sensor system test
- Check plug and wiring harness to pre-cat oxygen sensor LSVK B2
- Check induction system and exhaust system for leaks
- Replace oxygen sensor
MIL
* relative charge within the limits K_LAVK_OBD_PLAU_RF_MAX and K_LAVK_OBD_PLAU_RF_MIN; no dynamic response
MIL on after engine runs 2x
0x27C4
10180
Ambient pressure, plausibility
Ambient Pressure Sensor
Electrical
pumg_modell-pumg_roh| > K_PUMG_OBD_MODELL_DELTA_MAX
40000 ms
Engine running
none
tumg > -15 °C
>40000 ms
none
none
Y
pumg sensor indicates implausible value
- Clear fault memory
- Read analog data with SGBD and compare with current barometric pressure - Important: pumg is not calibrated to sea level, but to actual pressure, that is, starting with roughly 1000 hPa at sea level there is a continuous pressure drop of roughly 10mbar for every 100 meters of altitude.
- If still defective - with relation to deviation between DME barometric pressure and actual barometric pressure - replace DME as indicated
MIL
Cummulative VL time > 30 s (also possible in both P modes at low n in high gears) or B_ZUST_MS_A
pumg sensor value is within plausible range, but shows substantial deviation from model value, or displays an implausibly steep gradient
0x2711
10001
Ambient-pressure sensor
Ambient Pressure Sensor
Electrical
Measured value <= 1100mbar K_PUMG_DIAG_MIN
2000 ms
Wakeup
none
none
>2000 ms
none
none
N
Barometric pressure sensor - Maximum pressure implausible/signal short to ground
- Clear fault memory
- If error codes are still present replace the DME
MIL, CC message
none
MIL on after engine runs 2x
0x2711
10001
Ambient-pressure sensor
Ambient Pressure Sensor
Electrical
Measured value >= 400 mbar K_PUMG_DIAG_MAX
2000 ms
Wakeup
none
none
>2000 ms
none
none
N
Barometric pressure sensor - Maximum pressure implausible/ signal short to battery voltage or open circuit
- Clear fault memory
- If error codes are still present replace the DME
MIL, CC message
none
MIL on after engine runs 2x
0x274E
10062
Oxygen sensor fault, cable before catalytic converter bank 1
Oxygen Sensor, Front
Reference Voltage
*Query at controller at MIN limit with oxygen sensor cold (heater error) => leads to oscillation deactivation *Check whether oxygen sensor voltage is less than threshold of 98 mV (K_LAVK_OBD_PLAU_UN_SCHW)
No Info.
Engine running - Condition idle or part-load
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) 150 °C < tabg < 950 °C (K_LAVK_OBD_PLAU_TKAT_MAX; K_LAVK_OBD_PLAU_TKAT_MIN) after renewed insertion
No Info.
none
Digital
Y
Open wire for cell voltage supply
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B1 (especially UN for Nernst cell voltage supply)
- If OK, replace oxygen sensor
MIL
*relative charge within the limits K_LAVK_OBD_PLAU_RF_MAX and K_LAVK_OBD_PLAU_RF_MIN; no dynamic response
MIL lamp on after engine runs 2x /Small influence on driveability
0x274F
10063
Oxygen sensor fault Nernst cable before catalytic converter, bank 2
Oxygen Sensor, Front
Reference Voltage
*Query at controller at MIN limit with oxygen sensor cold (heater error) => leads to oscillation deactivation *Check whether oxygen sensor voltage is less than threshold of 98 mV (K_LAVK_OBD_PLAU_UN_SCHW)
No Info.
Engine running - Condition idle or part-load
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) 150 °C < tabg < 950 °C (K_LAVK_OBD_PLAU_TKAT_MAX; K_LAVK_OBD_PLAU_TKAT_MIN) after renewed insertion
No Info.
none
Digital
Y
Open wire for Nernst cell voltage supply
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B2 (especially UN for Nernst cell voltage supply)
- If OK, replace oxygen sensor
MIL
*relative charge within the limits K_LAVK_OBD_PLAU_RF_MAX and K_LAVK_OBD_PLAU_RF_MIN; no dynamic response
MIL lamp on after engine runs 2x /Small influence on driveability
0x273A
10042
Oxygen sensor vibration check behind catalytic converter, bank 1
Oxygen Sensor, Rear
Signal Check
Trim control suspicion with observation of P component and I component leads to guided RICH control; if the post-cat oxygen sensor signal fails to respond accordingly, the error is assigned to the post-cat oxygen sensor
After K_LAVK_OBD_ACT_NK_F_CNT (1x) RICH control events the oxygen sensor sticks at LEAN
Engine running
none
CAT must have started (CAT temp. >350 °C)
>100 ms
none
Analog; 0--5V
N
Following RICH control event (active plausibility diagnosis) the oxygen sensor sticks at LEAN
- Check exhaust system for leaks
- If OK, replace post-cat oxygen sensor LSNK B1
MIL
Active trim control (steady-state operation between 2000 and 3000 RPM in part-load range. ... min. 120 sec.)
MIL on after engine runs 2x / no effects on driveability
0x273A
10042
Oxygen sensor vibration check behind catalytic converter, bank 1
Oxygen Sensor, Rear
Signal Check
Trim control suspicion with observation of P component and I component leads to guided LEAN control; if the post-cat oxygen sensor signal fails to respond accordingly, the error is assigned to the post-cat oxygen sensor
After K_LAVK_OBD_ACT_NK_M_CNT (1x) LEAN control events the oxygen sensor remains stuck at RICH
Engine running
none
CAT must have started (CAT temp. >350 °C)
>100 ms
none
Analog; 0--5V
N
Following LEAN control event (active plausibility diagnosis) the oxygen sensor sticks at RICH
- Check exhaust system for leaks
- If OK, replace post-cat oxygen sensor LSNK B1
MIL
Active trim control (steady-state operation between 2000 and 3000 RPM in part-load range. ... min. 120 sec.)
MIL on after engine runs 2x / no effects on driveability
0x273B
10043
Oxygen sensor vibration check behind catalytic converter, bank 2
Oxygen Sensor, Rear
Signal Check
Trim control suspicion with observation of P component and I component leads to guided RICH control; if the post-cat oxygen sensor signal fails to respond accordingly, the error is assigned to the post-cat oxygen sensor
After K_LAVK_OBD_ACT_NK_F_CNT (1x) RICH control events the oxygen sensor sticks at LEAN
Engine running
none
CAT must have started (CAT temp. >350 °C)
>100 ms
none
Analog; 0--5V
N
Following RICH control event (active plausibility diagnosis) the oxygen sensor sticks at LEAN
- Check exhaust system for leaks
- If OK, replace post-cat oxygen sensor LSNK B2
MIL
Active trim control (steady-state operation between 2000 and 3000 RPM in part-load range. ... min. 120 sec.)
MIL on after engine runs 2x / no effects on driveability
0x273B
10043
Oxygen sensor vibration check behind catalytic converter, bank 2
Oxygen Sensor, Rear
Signal Check
Trim control suspicion with observation of P component and I component leads to guided LEAN control; if the post-cat oxygen sensor signal fails to respond accordingly, the error is assigned to the post-cat oxygen sensor
After K_LAVK_OBD_ACT_NK_M_CNT (1x) LEAN control events the oxygen sensor remains stuck at RICH
Engine running
none
CAT must have started (CAT temp. >350 °C)
>100 ms
none
Analog; 0--5V
N
Following LEAN control event (active plausibility diagnosis) the oxygen sensor sticks at RICH
- Check exhaust system for leaks
- If OK, replace post-cat oxygen sensor LSNK B2
MIL
Active trim control (steady-state operation between 2000 and 3000 RPM in part-load range. ... min. 120 sec.)
MIL on after engine runs 2x / no effects on driveability
0x2788
10120
Fuel pressure, setpoint/actual-value comparison at maximum pressure
No Info.
No Info.
Fuel pressure too high at maximum pressure Deviation between specified/actual pressure > 20 % (K_PKS_OBD_Q_MAX)
No Info.
Engine running
Battery voltage > 10.9V (K_PKS_OBD_UB_MIN)
Tmot > -10 °C (K_PKS_OBD_TMOT_MIN)
No Info.
No Info.
No Info.
No Info.
Fuel pressure at 100 % - maximum pressure exceeded
- Carry out test routine
- Check fuel filter, replace as indicated
- Check plug and wiring harness at fuel pressure sensor, replace as indicated
- Check plug and wiring harness at the fuel pump, check pump and replace as indicated
MIL, EML, CC message, backup program
&& !ekp_obd_vl_t && !B_ZUST_SA && !B_ZUST_SB && pumg > K_PKS_OBD_PUMG_MIN && (!B_ED_PKS_PUMG_FEHLER) && !B_EGAS_FEHLER && (time_ml > K_PKS_OBD_TIME_ML_MIN) && abs (can_ay) < K_PKS_OBD_AY && can fst sum
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2788
10120
Fuel pressure, setpoint/actual-value comparison at maximum pressure
No Info.
No Info.
Fuel pressure too low at maximum pressure Deviation between specified/actual pressure > -20 % (K_PKS_OBD_Q_MIN)
No Info.
Engine running
Battery voltage > 10.9V (K_PKS_OBD_UB_MIN)
Tmot > -10 °C (K_PKS_OBD_TMOT_MIN)
No Info.
No Info.
No Info.
No Info.
Fuel pressure at 100 % - pressure too low
- Carry out test routine
- Check fuel filter, replace as indicated
- Check plug and wiring harness at fuel pressure sensor, replace as indicated
- Check plug and wiring harness at the fuel pump, check pump and replace as indicated
MIL, EML, CC message, backup program
&& !ekp_obd_vl_t && !B_ZUST_SA && !B_ZUST_SB && pumg > K_PKS_OBD_PUMG_MIN && (!B_ED_PKS_PUMG_FEHLER) && !B_EGAS_FEHLER && (time_ml > K_PKS_OBD_TIME_ML_MIN) && abs(can_ay) < K_PKS_OBD_AY && can fst sum
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2728
10024
Oxygen sensor, coast-mode diagnosis before cat., bank 1
Oxygen Sensor, Front
Deceleration
Oxygen sensor is available (via sensor temperature, no error code entries, etc.) but the AD value is less than 3398mV (K_LAVK_OBD_SA_SCHW) for a number of 2 (K_LAVK_OBD_SA_CNT) measurements
No Info.
Engine running - overrun condition
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) oxygen sensor temperature > K_LAVK_OBD_VK_TEMP
K_LAVK_OBD_SA_CNT-SA phases (2x), each with K_LAVK_OBD_SA_T-seconds (2.5s) lag period until the entire system is stabilized
none
Digital
Y
Signal too rich on overrun / Oxygen sensor is poisoned or open wire from VM or IP
- Check plug and wiring harness to pre-cat oxygen sensor LSVK B1 (focus on opens in wires for virtual ground and pumping current)
- Replace oxygen sensor
MIL
* The air mass K_LAVK_OBD_SA_ML_SUM must flow through after recognition of overrun status
MIL on after engine runs 2x
0x2729
10025
Oxygen sensor, coast-mode diagnosis before cat., bank 2
Oxygen Sensor, Front
Deceleration
Oxygen sensor is available (via sensor temperature, no error code entries, etc.) but the AD value is less than 3398mV (K_LAVK_OBD_SA_SCHW) for a number of 2 (K_LAVK_OBD_SA_CNT) measurements
No Info.
Engine running - overrun condition
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) oxygen sensor temperature > K_LAVK_OBD_VK_TEMP
K_LAVK_OBD_SA_CNT-SA phases (2x), each with K_LAVK_OBD_SA_T-seconds (2.5s) lag period until the entire system is stabilized
none
Digital
Y
Signal too rich on overrun / Oxygen sensor is poisoned or open wire from VM or IP
- Check plug and wiring harness to pre-cat oxygen sensor LSVK B2 (focus on opens in wires for virtual ground and pumping current)
- Replace oxygen sensor
MIL
* The air mass K_LAVK_OBD_SA_ML_SUM must flow through after recognition of overrun status
MIL on after engine runs 2x
0x2753
10067
ignition cylinder 1, activation
Ignition Coil
A Primary Circuit
Voltage at PIN A_S_ICC too low, ignition channel inactive
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to ground
- Check plug and wiring harness on M ignition coil
- Check M ignition coil as indicated
- If shorts to ground are entered for all cylinders check fuse for TERM87 power supply
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2753
10067
ignition cylinder 1, activation
Ignition Coil
A Primary Circuit
Current on PIN A_S_ICC too high with active ignition pulse
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness at M ignition coil
- Replace M ignition coil as indicated
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2754
10068
ignition cylinder 2, activation
Ignition Coil
B Primary Circuit
Voltage at PIN A_S_ICC too low, ignition channel inactive
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to ground
- Check plug and wiring harness on M ignition coil
- Check M ignition coil as indicated
- If shorts to ground are entered for all cylinders check fuse for TERM87 power supply
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2754
10068
ignition cylinder 2, activation
Ignition Coil
B Primary Circuit
Current on PIN A_S_ICC too high with active ignition pulse
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness at M ignition coil
- Replace M ignition coil as indicated
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2755
10069
ignition cylinder 3, activation
Ignition Coil
C Primary Circuit
Voltage at PIN A_S_ICC too low, ignition channel inactive
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to ground
- Check plug and wiring harness on M ignition coil
- Check M ignition coil as indicated
- If shorts to ground are entered for all cylinders check fuse for TERM87 power supply
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2755
10069
ignition cylinder 3, activation
Ignition Coil
C Primary Circuit
Current on PIN A_S_ICC too high with active ignition pulse
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness at M ignition coil
- Replace M ignition coil as indicated
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2756
10070
ignition cylinder 4, activation
Ignition Coil
D Primary Circuit
Voltage at PIN A_S_ICC too low, ignition channel inactive
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to ground
- Check plug and wiring harness on M ignition coil
- Check M ignition coil as indicated
- If shorts to ground are entered for all cylinders check fuse for TERM87 power supply
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2756
10070
ignition cylinder 4, activation
Ignition Coil
D Primary Circuit
Current on PIN A_S_ICC too high with active ignition pulse
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness at M ignition coil
- Replace M ignition coil as indicated
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2757
10071
ignition cylinder 5, activation
Ignition Coil
E Primary Circuit
Voltage at PIN A_S_ICC too low, ignition channel inactive
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to ground
- Check plug and wiring harness on M ignition coil
- Check M ignition coil as indicated
- If shorts to ground are entered for all cylinders check fuse for TERM87 power supply
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2757
10071
ignition cylinder 5, activation
Ignition Coil
E Primary Circuit
Current on PIN A_S_ICC too high with active ignition pulse
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness at M ignition coil
- Replace M ignition coil as indicated
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2758
10072
ignition cylinder 6, activation
Ignition Coil
F Primary Circuit
Voltage at PIN A_S_ICC too low, ignition channel inactive
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to ground
- Check plug and wiring harness on M ignition coil
- Check M ignition coil as indicated
- If shorts to ground are entered for all cylinders check fuse for TERM87 power supply
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2758
10072
ignition cylinder 6, activation
Ignition Coil
F Primary Circuit
Current on PIN A_S_ICC too high with active ignition pulse
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness at M ignition coil
- Replace M ignition coil as indicated
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2759
10073
ignition cylinder 7, activation
Ignition Coil
G Primary Circuit
Voltage at PIN A_S_ICC too low, ignition channel inactive
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to ground
- Check plug and wiring harness on M ignition coil
- Check M ignition coil as indicated
- If shorts to ground are entered for all cylinders check fuse for TERM87 power supply
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2759
10073
ignition cylinder 7, activation
Ignition Coil
G Primary Circuit
Current on PIN A_S_ICC too high with active ignition pulse
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness at M ignition coil
- Replace M ignition coil as indicated
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x275A
10074
ignition cylinder 8, activation
Ignition Coil
H Primary Circuit
Voltage at PIN A_S_ICC too low, ignition channel inactive
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to ground
- Check plug and wiring harness on M ignition coil
- Check M ignition coil as indicated
- If shorts to ground are entered for all cylinders check fuse for TERM87 power supply
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x275A
10074
ignition cylinder 8, activation
Ignition Coil
H Primary Circuit
Current on PIN A_S_ICC too high with active ignition pulse
8 operating cycles
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
> 8 operating cycles
none
Digital
N
Control-activation wire shorted to battery voltage
- Check plug and wiring harness at M ignition coil
- Replace M ignition coil as indicated
MIL, EML, CC message, backup program
Designation - Driver info is present
CC message, Engine speed limited Power reduction Rough idle
0x2776
10102
DMTL pump
EVAP System
Pump
Pumping current > 108 mA (K_DMTL_I_KURZSCHL)
Errors recognized 10x consecutively
TERM87
11V < ub < 14.5V (k_dmtl_ub_min; k_dmtl_ub_max) When started with tester: none.
2 °C < tumg < 38 °C (K_DMTL_TEMP_MIN; K_DMTL_TEMP_MAX) tmot_start > -15 °C (K_DMTL_TEMP_START_MIN); When started with tester: none.
50 ms after short circuit with pump active
DMTL
Measured pumping current
N
Pumping current short circuit deactivation / activation wire has short to battery voltage
- Clear fault memory, DMTL system test
- Check plug and wiring harness on DMTL module
- Replace DMTL module
MIL
Pump receiving activation signal
Driver cannot feel problem / no tank leakage diagnosis routines
0x2778
10104
DMTL heating
EVAP System
DMTL Heater
Driver diagnosis ATIC39 (current too low)
Errors recognized 10x consecutively
Terminal 15
Battery voltage >10V (K_DIAG_TR_ED_UB_MIN)
none
roughly 1s when heater is triggered
none
Internal driver diagnosis
N
Open wire
- Clear fault memory, DMTL system test
- Check plug and wiring harness on DMTL module
- Replace DMTL module
MIL
Engine running (heater triggered)
Driver does not notice Error code be logged in ECU DMTL pump moisture cancellation with MIL
0x2778
10104
DMTL heating
EVAP System
DMTL Heater
Driver diagnosis ATIC39 (voltage too low)
Errors recognized 10x consecutively
none
Battery voltage >10V (K_DIAG_TR_ED_UB_MIN)
none
Roughly 1s when heater is not triggered
none
Internal driver diagnosis
N
Wire has short to ground
- Clear fault memory, DMTL system test
- Check plug and wiring harness on DMTL module
- Replace DMTL module
MIL
Engine not running (heater not triggered)
Driver does not notice Error code be logged in ECU DMTL pump moisture cancellation with MIL
0x2778
10104
DMTL heating
EVAP System
DMTL Heater
Driver diagnosis ATIC39 (excessive current)
Errors recognized 10x consecutively
Terminal 15
Battery voltage >10V (K_DIAG_TR_ED_UB_MIN)
none
roughly 1s when heater is triggered
none
Internal driver diagnosis
N
Wire has short to battery voltage
- Clear fault memory, DMTL system test
- Check plug and wiring harness on DMTL module
- Replace DMTL module
MIL
Engine running (heater triggered)
Driver does not notice Error code be logged in ECU DMTL pump moisture cancellation with MIL
0x273C
10044
Oxygen sensor, part/full-load diagnosis, before cat., bank 1
Oxygen Sensor, Front
Exhaust Sample Error
Oxygen sensor voltage less than 4800 mV (K_LAVK_OBD_TL_SCHW_MAX) and greater than 3149 mV (K_LAVK_OBD_TL_SCHW_MIN) for a total of 1 (K_LAVK_OBD_TL_CNT) after a lag period before active functionality of 8s (K_LAVK_OBD_TL_T) seconds
K_LAVK_OBD_TL_T- seconds (8s) lag frr K_LAVK_OBD_TL_CNT-attempts (1x)
Engine running - Condition part-load or full-load
none
Engine temperature > -14 °C (K_LAVK_OBD_TMOT) oxygen sensor temperature > K_LAVK_OBD_VK_TEMP
>800 ms
none
Digital
Y
Oxygen sensor exposed to ambient air
- Install oxygen sensor in exhaust system (oxygen sensor exposed to ambient air)
MIL
*Since detection of reinstallation an air mass flow of K_LAVK_OBD_TL_ML_SUM has occurred
MIL on after engine runs 2x Possible negative effects on driveability
0x273D
10045
Oxygen sensor, part/full-load diagnosis, before cat., bank 2
Oxygen Sensor, Front
Exhaust Sample Error
Oxygen sensor voltage less than 4800 mV (K_LAVK_OBD_TL_SCHW_MAX) and greater than 3149 mV (K_LAVK_OBD_TL_SCHW_MIN) for a total of 1 (K_LAVK_OBD_TL_CNT) after a lag period before active functionality of 8s (K_LAVK_OBD_TL_T) seconds
K_LAVK_OBD_TL_T- seconds (8s) lag frr K_LAVK_OBD_TL_CNT-attempts (1x)
Engine running - Condition part-load or full-load
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) oxygen sensor temperature > K_LAVK_OBD_VK_TEMP
>800 ms
none
Digital
Y
Oxygen sensor exposed to ambient air
- Install oxygen sensor in exhaust system (oxygen sensor exposed to ambient air)
MIL
*Since detection of reinstallation an air mass flow of K_LAVK_OBD_TL_ML_SUM has occurred
MIL on after engine runs 2x Possible negative effects on driveability
0x2777
10103
DMTL valve
EVAP System
Switching Valve
Driver diagnosis ATIC39 (current too low)
Errors recognized 10x consecutively
TERM87
11V < ub < 14.5V (k_dmtl_ub_min; k_dmtl_ub_max) When started with tester: >10 V (K_DIAG_TR_ED_UB_MIN)
2 °C < tumg < 38 °C (K_DMTL_TEMP_MIN; K_DMTL_TEMP_MAX) tmot_start > -15 °C (K_DMTL_TEMP_START_MIN); None when started with tester.
roughly 1 sec. with activation signal to valve
DMTL
Internal driver diagnosis
N
Open control-activation power supply wire/defective valve
- Clear fault memory, DMTL system test
- Check plug and wiring harness on DMTL module
- Replace DMTL module
MIL
Valve triggered
Driver cannot feel problem / no tank leakage diagnosis routines
0x2777
10103
DMTL valve
EVAP System
Switching Valve
Driver diagnosis ATIC39 (voltage too low)
Errors recognized 10x consecutively
TERM87
11V < ub < 14.5V (k_dmtl_ub_min; k_dmtl_ub_max) When started with tester: >10 V (K_DIAG_TR_ED_UB_MIN)
2 °C < tumg < 38 °C (K_DMTL_TEMP_MIN; K_DMTL_TEMP_MAX) tmot_start > -15 °C (K_DMTL_TEMP_START_MIN); None when started with tester.
roughly 1 sec. with no activation signal to valve
DMTL
Internal driver diagnosis
N
Control-activation wire shorted to ground7 / defective valve
- Clear fault memory, DMTL system test
- Check plug and wiring harness on DMTL module
- Replace DMTL module
MIL
Valve not triggered
Driver cannot feel problem / no tank leakage diagnosis routines
0x2777
10103
DMTL valve
EVAP System
Switching Valve
Driver diagnosis ATIC39 (excessive current)
Errors recognized 10x consecutively
TERM87
11V < ub < 14.5V (k_dmtl_ub_min; k_dmtl_ub_max) When started with tester: >10 V (K_DIAG_TR_ED_UB_MIN)
2 °C < tumg < 38 °C (K_DMTL_TEMP_MIN; K_DMTL_TEMP_MAX) tmot_start > -15 °C (K_DMTL_TEMP_START_MIN); None when started with tester.
roughly 1 sec. with activation signal to valve
DMTL
Internal driver diagnosis
N
Control wire shorted to battery voltage/defective valve
- Clear fault memory, DMTL system test
- Check plug and wiring harness on DMTL module
- Replace DMTL module
MIL
Valve triggered
Driver cannot feel problem / no tank leakage diagnosis routines
0x2739
10041
Air-mass sensor, secondary air, electrical diagnosis
Secondary Mass Air Flow Sensor/Pressure Sensor
Electrical
Air mass > 0.5 kg/h (K_SL_ML_HFM_OFFSET_MIN)
5 ms
Engine off
none
No Info.
>5 ms
SLS test routine
Analog; 0--5V
N
Sensor signal indicates air mass value > 0.5 kg/h from
- Check plug and wiring harness on Mini-HFM
- Replace Mini-HFM
MIL
TERM87 on time_ms > K_SL_HFM_DIAG_T_MIN
MIL on after engine runs 2x
0x27C5
10181
Air-mass sensor, secondary air, plausibility
Secondary Mass Air Flow Sensor/Pressure Sensor
Electrical
sls_obd_max after 10 sec. SLS operation under KL_SLS_OBD_HFM_DIAG_MIN or after 20 sec. SLS_operation sls_obdh_mdf_max_intg_norm < K_SLS_OBDH_EUV_MIN_DEF and higher exhaust gas lamda
30000 ms
Engine running
Battery voltage > 10.8V (k_sls_obd_ub_min)
tmot(start) > -3 °C
>30000 ms
SLS test routine
none
Y
Mini-HFM defective
- Remove secondary air line from secondary air pump
- Conduct test routine
- If secondary air pump runs/air flows out, and error is still logged, replace the mini-HFM
MIL
SLS conditions continuously satisfied SLS has run at least 10s
MIL is on after 2x engine cold start
0x2739
10041
Air-mass sensor, secondary air, electrical diagnosis
Secondary Mass Air Flow Sensor/Pressure Sensor
Electrical
Air mass < -10kg/h K_SL_ML_HFM_DIAG_MIN
5 ms
Engine running
none
none
>5 ms
SLS test routine
Analog; 0--5V
N
Sensor voltage too low / signal shorted to ground / no Term 87 power supply / no reference voltage / open wire
- Check plug and wiring harness on Mini-HFM
- Replace Mini-HFM
MIL
none
MIL on after engine runs 2x
0x2739
10041
Air-mass sensor, secondary air, electrical diagnosis
Secondary Mass Air Flow Sensor/Pressure Sensor
Electrical
Air mass > 70 kg/h K_SL_ML_HFM_DIAG_MAX
5 ms
Engine running
none
none
>5 ms
SLS test routine
Analog; 0--5V
N
Sensor voltage too high / signal shorted to battery voltage / no ground / reference voltage shorted to battery voltage
- Check plug and wiring harness on Mini-HFM
- Replace Mini-HFM
MIL
none
MIL on after engine runs 2x
0x27B0
10160
Secondary air system flow rate, bank 1
Secondary Air System
Valve
sls_obdh_mdf_max_intg_norm (after end of SLS operation)>K_SLS_OBDH_SLV_MA X sls_obdh_lam_asv_intg_norm above threshold
30000 ms
Engine running
Battery voltage > 10.8V (k_sls_obd_ub_min)
tmot(start) > -3 °C
>30000 ms
SLS test routine
none
Y
Bank 1 shut-off valve seized open / ASV seized open / long-term danger of soot accumulation
- Conduct test routine
- Replace ASV air switching valve as indicated
MIL
continuously satisfies SLS conditions
MIL is on after 2x engine cold start
0x27B2
10162
Secondary air system flow rate, main branch
Secondary Air System
Valve
sls_obdh_lam_asv_intg_norm above threshold
30000 ms
Engine running
Battery voltage > 10.8V (k_sls_obd_ub_min)
tmot(start) > -3 °C
>30000 ms
SLS test routine
none
Y
Electric pilot valve sticks open
- Replace electric pilot valve
- If fault is still present, look for leaks in main line.
MIL
continuously satisfies SLS conditions
MIL is on after 2x engine cold start
0x27B1
10161
Secondary air system flow rate, bank 2
Secondary Air System
Valve
sls_obdh_mdf_max_intg_norm (after end of SLS operation)>K_SLS_OBDH_SLV_MA X sls_obdh_lam_asv_intg_norm above threshold
30000 ms
Engine running
Battery voltage > 10.8V (k_sls_obd_ub_min)
tmot(start) > -3 °C
>30000 ms
SLS test routine
none
Y
Bank 2 shut-off valve seized open / ASV seized open / long-term danger of soot accumulation
- Conduct test routine
- Replace ASV air switching valve as indicated
MIL
continuously satisfies SLS conditions
MIL is on after 2x engine cold start
0x27B0
10160
Secondary air system flow rate, bank 1
No Info.
No Info.
sls_obdh_mdf_max_intg_norm (after roughly 30 s.)>K_SLS_OBDH_MDF_MIN_DEF and sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_MDF_2_MAG or sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_ASV_LI_OPE and K_SLS_OBDH_MDF_MIN_DEF<K_SLS_OBDH_MDF_MAX_DEF
30000 ms
Engine running
Battery voltage > 10.8V (k_sls_obd_ub_min)
tmot(start) > -3 °C
>30000 ms
SLS test routine
none
Y
Secondary air ground too high: Leak in Bank 1 line
- Check Bank 1 secondary air line for tight fit on ASV air switching valve / check for leaks.
MIL
continuously satisfies SLS conditions
MIL is on after 2x engine cold start
0x27B1
10161
Secondary air system flow rate, bank 2
No Info.
No Info.
sls_obdh_mdf_max_intg_norm (after roughly 30 s.)>K_SLS_OBDH_MDF_MIN_DEF and sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_MDF_2_MAG or sls_obdh_lam_asv_intg_norm > k_SLS_OBDH_ASV_RE_OPE and K_SLS_OBDH_MDF_MIN_DEF<K_SLS_OBDH_MDF_MAX_DEF
30000 ms
Engine running
Battery voltage > 10.8V (k_sls_obd_ub_min)
tmot(start) > -3 °C
>30000 ms
SLS test routine
none
Y
Secondary air ground too high: Bank 2 line leaking
- Check Bank 2 secondary air line for tight fit on ASV/check for leaks.
MIL
continuously satisfies SLS conditions
MIL is on after 2x engine cold start
0x279E
10142
Oil condition sensor
Engine Oil Level
Level
B_oz_oelverlust_CC = TRUE (also: Oz_anzeige_kombi < K_OZ_CC_OELVERLUST)
20000 ms
Engine running
Battery voltage > 9.985V (k_dtog_ubmin)
toel > 60 °C
>20000 ms
none
Digital
N
Engine oil below level of K_OZ_CC_OELVERLUST
Top up engine oil; check with short-period measurement
CC status report
BSD bit serial data interface communications with QLT OK; K_OZDIAGNMOT < n < K_OZDIAGNMOT2
CC status report: Engine oil level below minimum ! Top up engine oil
0x27E3
10211
Vacuum sensor, brake booster, plausibility
No Info.
No Info.
Sensor value deviates substantially from model value, with sensor value > Model value ensuring that ELUP activation threshold remains valid
1 min
Engine running
none
none
>1 min
MVAC test routine
none
Y
Vacuum line, RSV or hose connection defective
- Check vacuum line
- Check 1-way check valves
- Check brake booster
MIL
No catalyst heating, no braking
MIL on after engine runs 2x
0x27E3
10211
Vacuum sensor, brake booster, plausibility
No Info.
No Info.
Sensor value displays substantial deviation from model value, with model value < Model value, at which ELUP activation threshold is not ensured
1 min
Engine running
none
none
>1 min
MVAC test routine
none
Y
Differential pressure sensor seizes
- Check plug and wire to differential pressure sensor
- Replace differential pressure sensor
MIL, EML, CC message, backup program
No catalyst heating, no braking, B_SA or B_ZUST_LL
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2794
10132
Vacuum sensor, brake booster, signal
No Info.
No Info.
mvac_p >= K MVAC P DIAG MAX
500 ms
Engine running
none
none
>500 ms.
MVAC test routine
Analog; 0.3--4.8V
N
Differential pressure sensor - Maximum pressure implausible/signal short to ground
- Check electrical wiring
- Use tester to read out sensor data
- Replace differential pressure sensor
MIL, EML, CC message, backup program
none
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2796
10134
not translated
No Info.
No Info.
Safety-critical malfunction
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Not a malfunction, only the response: Torque is limited
This fault memory entry is always a collateral error. The only way to rectify it is by resolving the malfunctions behind any other displayed fault memory entries.
EML, CC message, backup program
This fault memory entry is always a collateral error
CC message, Engine speed limited Reduced power
0x2798
10136
not translated
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2799
10137
not translated
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2794
10132
Vacuum sensor, brake booster, signal
No Info.
No Info.
mvac_p <= K_MVAC_P_DIAG_MIN
500 ms
Engine running in CAT heating phase
none
none
>500 ms.
MVAC test routine
Analog; 0.3--4.8V
N
Differential pressure sensor - Minimum pressure implausible / signal shorted to battery voltage or open circuit
- Check electrical wiring
- Use tester to read out sensor data
- Replace differential pressure sensor
MIL, EML, CC message, backup program
Condition for heating catalyst
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2796
10134
not translated
No Info.
No Info.
Safety-critical malfunction
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Not a malfunction, only the response: Cylinders are suppressed
This fault memory entry is always a collateral error. The only way to rectify it is by resolving the malfunctions behind any other displayed fault memory entries.
EML, CC message, backup program
This fault memory entry is always a collateral error
CC message, Engine speed limited Reduced power
0x2798
10136
not translated
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2799
10137
not translated
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2796
10134
not translated
No Info.
No Info.
Safety-critical malfunction
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Not a malfunction, only the response: E-Gas is deactivated
This fault memory entry is always a collateral error. The only way to rectify it is by resolving the malfunctions behind any other displayed fault memory entries.
EML, CC message, backup program
This fault memory entry is always a collateral error
CC message, Engine speed limited Reduced power
0x2798
10136
not translated
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2799
10137
not translated
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2796
10134
not translated
No Info.
No Info.
Safety-critical malfunction
10 ms
Terminal 15
none
none
>10 ms
none
none
Y
Not a malfunction, only the response: Reset was triggered
This fault memory entry is always a collateral error. The only way to rectify it is by resolving the malfunctions behind any other displayed fault memory entries.
EML, CC message, backup program
This fault memory entry is always a collateral error
CC message, Engine speed limited Reduced power
0x2798
10136
not translated
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x2799
10137
not translated
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x279F
10143
Electronics-box fan, activation
No Info.
No Info.
Current > ???A
1000 ms
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
>1000 ms
none
Digital
N
Current too high / control-activation wire shorted to positive
- Check plug and wiring harness at fan
- Replace E-box fan
none
If triggered
Driver does not notice. Control module overheating possible
0x279F
10143
Electronics-box fan, activation
No Info.
No Info.
Voltage < ???A
1000 ms
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
>1000 ms
none
Digital
N
Voltage too low / short to ground in control-activation wire
- Check plug and wiring harness at fan
- Replace E-box fan
none
if not triggered
Driver does not notice.
0x279E
10142
Oil condition sensor
Engine Oil Quality Sensor
Electrical
none
20000 ms
Engine running
Battery voltage > 9.985V (k_dtog_ubmin)
toel > 60 °C
>20000 ms
none
Digital
N
- Oil sensor (BSD BUS) not connected
- Open wire (BSD BUS) between oil sensor and DME
- Defective oil sensor
Check oil quality sensor (plug and wire)
CC status report
This error location is not used for QLT (instead 1_126 / 0x278E)
none
0x279F
10143
Electronics-box fan, activation
No Info.
No Info.
Current < ???A
1000 ms
TERM87
Battery voltage > 9.8 V (k_diag_tr_ub_min)
none
>1000 ms
none
Digital
N
Current too low / open control activation wire / Versor
- Check plug and wiring harness at fan
- Replace E-box fan
none
If triggered
Driver does not notice. Control module overheating possible
0x279E
10142
Oil condition sensor
Engine Oil Quality Sensor
Electrical
none
20000 ms
Engine running
Battery voltage > 9.985V (k_dtog_ubmin)
toel > 60 °C
>20000 ms
none
Digital
N
Error in oil level measurement / Permitivity measurement error (oil sensor self-diagnosis)
Check oil quality sensor (plug and wire)
none
This error location is not used for QLT (instead 1_126 / 0x278E)
none
0x274A
10058
Oxygen sensor pump current calibration fault before cat. converter, bank 1
Oxygen Sensor, Front
Pumping Current
Oxygen sensor is available, oxygen sensor voltage > 4951 mV (K_LAVK_OBD_SA_DIAG_OL)
after a defined SA phase the lag period K_LAVK_OBD_SA_T (2.5 sec) must be completed
Engine running - overrun condition
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) Oxygen sensor temperature > 300 °C (K_LAVK_OBD_VK_TEMP)
No logical time definition, as a defined SA phase is required
none
Digital
Y
Open oxygen sensor trim circuit wire IA
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B1 (especially trim circuit wire IA)
- If OK, replace oxygen sensor, replace DME as indicated
MIL
*the flow since overrun was detected must have an air mass of K_LAVK_OBD_SA_ML_SUM
MIL lamp on after engine runs 2x /Small influence on driveability
0x274B
10059
Oxygen sensor pump current calibration fault before cat. converter, bank 2
Oxygen Sensor, Front
Pumping Current
Oxygen sensor is available, oxygen sensor voltage > 4951 mV (K_LAVK_OBD_SA_DIAG_OL)
after a defined SA phase the lag period K_LAVK_OBD_SA_T (2.5 sec) must be completed
Engine running - overrun condition
none
Tmot > -14 °C (K_LAVK_OBD_TMOT) Oxygen sensor temperature > 300 °C (K_LAVK_OBD_VK_TEMP)
No logical time definition, as a defined SA phase is required
none
Digital
Y
Open oxygen sensor trim circuit wire IA
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B2 (especially trim circuit wire IA)
- If OK, replace oxygen sensor
MIL
*the flow since overrun was detected must have an air mass of K_LAVK_OBD_SA_ML_SUM
MIL lamp on after engine runs 2x /Small influence on driveability
0x2787
10119
Fuel pressure, setpoint/actual-value comparison, controlled operation
No Info.
No Info.
Deviation between specified/actual pressure > 20 % (K_PKS_OBD_LL_MAX)
10000 ms
Engine running
Battery voltage > 10.9V (K_PKS_OBD_UB_MIN)
Tmot > -10 °C (K_PKS_OBD_TMOT_MIN)
>10000 ms
No Info.
No Info.
No Info.
Fuel pressure too low / activation wire shorted to ground or open wire / filter plugged / defective EKP electric fuel pump / defective sensor
- Carry out test routine
- Check fuel filter, replace as indicated
- Check plug and wiring harness at fuel pressure sensor, replace as indicated
- Check plug and wiring harness at the fuel pump, check pump and replace as indicated
MIL, EML, CC message, backup program
&& !ekp_obd_vl_t && !B_ZUST_SA && !B_ZUST_SB && pumg > K_PKS_OBD_PUMG_MIN && (!B_ED_PKS_PUMG_FEHLER) && !B_EGAS_FEHLER && (time_ml > K_PKS_OBD_TIME_ML_MIN) && abs(can_ay) < K_PKS_OBD_AY && can fst sum
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2787
10119
Fuel pressure, setpoint/actual-value comparison, controlled operation
No Info.
No Info.
Deviation between actual/specified pressure < -15 % (K_PKS_OBD_LL_MIN)
10000 ms
Engine running
Battery voltage > 10.9V (K_PKS_OBD_UB_MIN)
Tmot > -10 °C (K_PKS_OBD_TMOT_MIN)
>10000 ms
No Info.
No Info.
No Info.
Fuel pressure too high / activation wire shorted to positive / defective EKP electric fuel pump / defective sensor
- Carry out test routine
- Check fuel filter, replace as indicated
- Check plug and wiring harness at fuel pressure sensor, replace as indicated
- Check plug and wiring harness at the fuel pump, check pump and replace as indicated
MIL, EML, CC message, backup program
&& !ekp_obd_vl_t && !B_ZUST_SA && !B_ZUST_SB && pumg > K_PKS_OBD_PUMG_MIN && (!B_ED_PKS_PUMG_FEHLER) && !B_EGAS_FEHLER && (time_ml > K_PKS_OBD_TIME_ML_MIN) && abs(can_ay) < K_PKS_OBD_AY && can_fst_sum
CC message, Engine speed limited Reduced power MIL after engine runs 2x
0x2746
10054
Oxygen sensor, reference-resistance diagnosis, before cat., bank 1
Oxygen Sensor, Front
ECM Self-Test
LA-Ri offset adaptation value less than -73 mV (K_LSRVK_OBD_REF_OFFS_MIN) or greater than 73 mV (K_LSRVK_OBD_REF_OFFS_MAX ) for 3 (K_LSRVK_OBD_REF_OFFS_CNT ) offset adaptations
K_LSRVK_OBD_REF_OFFS_CNT (2x) incorrect diagnostic results
Engine running - Condition idle or part-load
Battery voltage > 9V (k_ed_ubmin)
none
>200 sec. (varies according to accompanying conditions)
none
none
Y
With oxygen sensor disconnected output voltage of processing chip ATIC42 is implausible relative to reference voltage
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B1
- If OK, replace oxygen sensor, replace DME as indicated
MIL
Oxygen sensor Ri-OFFSET adaptation in progress
MIL lamp on after engine runs 2x /Small influence on driveability
0x2747
10055
Oxygen sensor, reference-resistance diagnosis, before cat., bank 2
Oxygen Sensor, Front
ECM Self-Test
LA-Ri offset adaptation value less than -73 mV (K_LSRVK_OBD_REF_OFFS_MIN) or greater than 73 mV (K_LSRVK_OBD_REF_OFFS_MAX ) for 3 (K_LSRVK_OBD_REF_OFFS_CNT ) offset adaptations
K_LSRVK_OBD_REF_OFFS_CNT (2x) incorrect diagnostic results
Engine running - Condition idle or part-load
Battery voltage > 9V (k_ed_ubmin)
none
>200 sec. (varies according to accompanying conditions)
none
none
Y
With oxygen sensor disconnected output voltage of processing chip ATIC42 is implausible relative to reference voltage
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B2
- If OK, replace oxygen sensor, or replace DME as indicated
MIL
Oxygen sensor Ri-OFFSET adaptation in progress
MIL lamp on after engine runs 2x /Small influence on driveability
0x27D2
10194
Oxygen sensor before cat., bank 1, evaluation module in control module
Oxygen Sensor, Front
ECM Self-Test
No SPI communications
2000 ms
Terminal 15
none
none
>2000 ms
none
Digital
N
SPI communications error from driver chip in oxygen sensor
- Check oxygen sensor plug and wiring harness
- Replace oxygen sensor
- Replace engine-management unit
MIL
none
No Info.
0x27D4
10196
Oxygen sensor before cat., bank 2, evaluation module in control module
Oxygen Sensor, Front
ECM Self-Test
No SPI communications
2000 ms
Terminal 15
none
none
>2000 ms
none
Digital
N
SPI communications error from driver chip in oxygen sensor
- Check oxygen sensor plug and wiring harness
- Replace oxygen sensor
- Replace engine-management unit
MIL
none
No Info.
0x2740
10048
Oxygen sensor heating control diagnosis before catalytic converter, bank 1
Oxygen Sensor, Front
Heater
Heater controller hangs up for a certain period 10s (K_LSRVK_OBD_REG_T) at limit
10000 ms
Engine running - Condition idle or part-load
Battery voltage > 9V (k_ed_ubmin)
200 °C < tkat < 850 °C (K_LSRVK_OBD_TKAT_MAX; K_LSRVK_OBD_TKAT_MAX)
>10000 ms
none
PWM
N
Open signal wire / defective oxygen sensor
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B1
- If OK replace oxygen sensor
MIL
*Engine running for at the time K_LSRVK_OBD_TML *min. superimposed integrated air mass after WE K_LSRVK_OBD_ML_SUM *Oxygen sensor heater controller is active
MIL lamp on after engine runs 2x /Small influence on driveability
0x2741
10049
Oxygen sensor heating control diagnosis before catalytic converter, bank 2
Oxygen Sensor, Front
Heater
Heater controller hangs up for a certain period 10s (K_LSRVK_OBD_REG_T) at limit
10000 ms
Engine running - Condition idle or part-load
Battery voltage > 9V (k_ed_ubmin)
200 °C < tkat < 850 °C (K_LSRVK_OBD_TKAT_MAX; K_LSRVK_OBD_TKAT_MAX)
>10000 ms
none
PWM
N
Open signal wire / defective oxygen sensor
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B2
- If OK, replace oxygen sensor
MIL
*Engine running for at the time K_LSRVK_OBD_TML *min. superimposed integrated air mass after WE K_LSRVK_OBD_ML_SUM *Oxygen sensor heater controller is active
MIL lamp on after engine runs 2x /Small influence on driveability
0x2746
10054
Oxygen sensor, reference-resistance diagnosis, before cat., bank 1
Oxygen Sensor, Front
Resistance
LA-Ri offset adaptation value less than -73 mV (K_LSRVK_OBD_REF_OFFS_MIN) or greater than 73 mV (K_LSRVK_OBD_REF_OFFS_MAX ) for 3 (K_LSRVK_OBD_REF_OFFS_CNT ) offset adaptations
K_LSRVK_OBD_REF_CNT (2x) incorrect diagnostic results
Engine running - Condition idle or part-load
Battery voltage > 9V (k_ed_ubmin)
none
>200 sec. (varies according to accompanying conditions)
none
none
Y
Reference resistance in control module is not equal to measured value of Nernst cell
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B1
- If OK, replace oxygen sensor, replace DME as indicated
MIL
Oxygen sensor Ri-GAIN adaptation in progress
MIL lamp on after engine runs 2x /Small influence on driveability
0x2748
10056
Oxygen sensor before cat., evaluation module in control module, bank 1
No Info.
No Info.
lavk_atic42_diag_byte_b1 BIT4 is set
3 sec.
none
none
none
>3 sec.
none
Digital
N
ATIC42 chip detects defective oxygen sensor / Collateral error when virtual ground is shorted to positive
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B1
- If OK replace oxygen sensor
none
Chip designates a received telegram
MIL lamp on after engine runs 2x /Small influence on driveability
0x2749
10057
Oxygen sensor before cat., evaluation module in control module, bank 2
No Info.
No Info.
lavk_atic42_diag_byte_b2 BIT4 is set
3 sec.
none
none
none
>3 sec.
none
Digital
N
ATIC42 chip detects defective oxygen sensor / Collateral error when virtual ground is shorted to positive
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B2
- If OK, replace oxygen sensor
none
Chip designates a received telegram
MIL lamp on after engine runs 2x /Small influence on driveability
0x2748
10056
Oxygen sensor before cat., evaluation module in control module, bank 1
No Info.
No Info.
lavk_atic42_diag_byte_b1 BIT3 is set
3 sec.
none
none
none
>3 sec.
none
Digital
N
ATIC42 chip detects defective oxygen sensor
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B1
- If OK replace oxygen sensor
none
Chip designates a received telegram
MIL lamp on after engine runs 2x /Small influence on driveability
0x2749
10057
Oxygen sensor before cat., evaluation module in control module, bank 2
No Info.
No Info.
lavk_atic42_diag_byte_b2 BIT3 is set
3 sec.
none
none
none
>3 sec.
none
Digital
N
ATIC42 chip detects defective oxygen sensor
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B2
- If OK, replace oxygen sensor
none
Chip designates a received telegram
MIL lamp on after engine runs 2x /Small influence on driveability
0x2748
10056
Oxygen sensor before cat., evaluation module in control module, bank 1
No Info.
No Info.
lavk_atic42_diag_byte_b1 BIT1 or BIT2 is set
3 sec.
none
none
none
>3 sec.
none
Digital
N
ATIC42 chip detects defective oxygen sensor
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B1
- If OK replace oxygen sensor
none
Chip designates a received telegram
MIL lamp on after engine runs 2x /Small influence on driveability
0x2749
10057
Oxygen sensor before cat., evaluation module in control module, bank 2
No Info.
No Info.
lavk_atic42_diag_byte_b2 BIT1 or BIT2 is set
3 sec.
none
none
none
>3 sec.
none
Digital
N
ATIC42 chip detects defective oxygen sensor
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B2
- If OK, replace oxygen sensor
none
Chip designates a received telegram
MIL lamp on after engine runs 2x /Small influence on driveability
0x2747
10055
Oxygen sensor, reference-resistance diagnosis, before cat., bank 2
Oxygen Sensor, Front
Resistance
LA-Ri offset adaptation value less than -73 mV (K_LSRVK_OBD_REF_OFFS_MIN) or greater than 73 mV (K_LSRVK_OBD_REF_OFFS_MAX ) for 3 (K_LSRVK_OBD_REF_OFFS_CNT ) offset adaptations
K_LSRVK_OBD_REF_CNT (2x) incorrect diagnostic results
Engine running - Condition idle or part-load
Battery voltage > 9V (k_ed_ubmin)
none
>200 sec. (varies according to accompanying conditions)
none
none
Y
Reference resistance in control module is not equal to measured value of Nernst cell
- Check plug and wiring harness on pre-cat oxygen sensor LSVK B2
- If OK, replace oxygen sensor, or replace DME as indicated
MIL
Oxygen sensor Ri-GAIN adaptation in progress
MIL lamp on after engine runs 2x /Small influence on driveability
0x2B66
11110
Parallel connection, coolant temperature sensor
Engine Coolant
Temperature
Following extended time with the vehicle parked K_TMOT_OBD_HIGH_TIME (10 hrs.) the sensor still indicates a high coolant temperature K_TMOT_OBD_HIGH (68 °C)
2000 ms
B_ZUST_MS_A && B EMPF ATEMP
none
Tmot > 68 °C
>2000 ms
none
analog
N
Sensor continues to measure high coolant temperature even after vehicle is parked a considerable time
- Check plug and wiring harness
- Replace coolant temperature sensor
MIL
Engine off
Idle speed may be brielfy higher after engine start
0x2AF9
11001
Coolant temperature sensor
Engine Coolant
Temperature
Measured value gradient > K_TMOT_DIAG_GRAD_MAX
2000 ms
none
none
none
>2000 ms
none
analog
N
Measured value gradient exceeds K_TMOT_DIAG_GRAD_MAX
- Check plug and wiring harness
- Replace coolant temperature sensor
MIL
none
MIL lamp comes on after engine runs 2x / idle may be high for brief period after engine start
0xCD94
52628
Message 0x310 (outside temperature)
Communication
Powertrain
100 (K_ED_PT_ATEMP.ERROR THRESHOLD)
19900 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>19900 ms
none
PT CAN
N
Internal DME ECU fault
- Replace SGM ECU
MIL
Bus active
Outside temperature display failed
0xCD87
52615
PT-CAN bus communication fault
Communication
Powertrain
20 (K_ED_PT_BUSOFF.ERROR THRESHOLD)
100 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>100 ms
none
PT CAN
N
PT CAN shorted High with Low/ PT CAN-High short to battery voltage/ PT CAN-Low shorted to ground
was E60 series AG
none
Bus active
CC message, / power reduction / no engine speed-gear-speed-coolant temperature display / higher idle / starter does not disengage if shutdown phase not awaited / not possible to read out stored error codes
0xCD94
52628
Message 0x310 (outside temperature)
Communication
Powertrain
No new messages
19900 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>19900 ms
none
PT CAN
N
No power supply to SGM security and gateway module ECU / open wire SGM-CAN / CAN wire defective / defective I-cluster
- Check plug and wiring harness at security gateway module SGM ECU
- Replace security gateway module SGM ECU
MIL
Bus active
Outside temperature display failed
0x27E7
10215
Limp-home operation, 100 % el. fuel pump activation
No Info.
No Info.
CAN link - Alive counter
1
none
none
none
>10 ms
none
none
Y
Problem with local CAN link between DME and electric fuel pump module
Check wiring and plug-in contacts for CAN connection
MIL, CC message
Diagnosis running in the DME
CC status report
0xCDB8
52664
Message 0xB8 (twin-clutch transmission)
No Info.
No Info.
Internal error
145 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>145 ms
none
PT CAN
N
Internal DME
- Replace DME ECU
none
Bus active
Rough shifting
0xCDB4
52660
Message (gearbox data, 3B1)
No Info.
No Info.
K_ED_PT_GRB 3rd ERROR THRESHOLD
500 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>500 ms.
none
PT CAN
N
Internal DME ECU fault
- Replace DME ECU
none
Bus active
CC message, error, DKG throttle valve sensor not operating / DKG lamp
0xCDB4
52660
Message (gearbox data, 3B1)
No Info.
No Info.
Checksum incorrect for K_CAN_CHKSUM_ERR_MAX cycles
500 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>500 ms.
none
PT CAN
N
Internal malfunction in DKG throttle valve sensor ECU or in DME ECU
- Replace DKG throttle valve sensor ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCDAF
52655
Message 0x24e (trailer status)
No Info.
No Info.
No new messages
200000 ms.
Terminal 15
Battery voltage > 9 V
none
>200000 ms.
none
PT CAN
N
No power to AHM / open wire between AHM-CAN / CAN wire defective, defective transmitter
- Check plug and wiring harness on AHM
- Replace AHM
none
none
Driver does not notice
0xCDB0
52656
Message (display, transmission data, 1D2)
No Info.
No Info.
No new messages
2400 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>2400 ms
none
PT CAN
N
No power supply to DKG throttle valve sensor ECU/ Open wire DKG-CAN, internal fault in DKG throttle valve sensor ECU
- Check plug and wiring harness at DKG throttle valve sensor ECU
- Replace DKG throttle valve sensor ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCDB4
52660
Message (gearbox data, 3B1)
No Info.
No Info.
No new messages
1000 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>1000 ms
none
PT CAN
N
No power supply to DKG throttle valve sensor ECU/ Open wire DKG-CAN, internal fault in DKG throttle valve sensor ECU
- Check plug and wiring harness at DKG throttle valve sensor ECU
- Replace DKG throttle valve sensor ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCDB8
52664
Message 0xB8 (twin-clutch transmission)
No Info.
No Info.
Alive counter stops for 5 (K_CAN_ALIVE_ERR_MAX) cycles
145 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>145 ms
none
PT CAN
N
DKG throttle valve sensor error
- Check/replace DKG throttle valve sensor ECU
none
Bus active
Rough shifting
0xCDB4
52660
Message (gearbox data, 3B1)
No Info.
No Info.
Alive counter stops for K_CAN_ALIVE_ERR_MAX cycles
500 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>500 ms.
none
PT CAN
N
Internal DKG throttle valve sensor ECU fault
- Replace DKG throttle valve sensor ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCDB8
52664
Message 0xB8 (twin-clutch transmission)
No Info.
No Info.
Checksum error for 5 (K_CAN_CHKSUM_ERR_MAX) cycles
145 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>145 ms
none
PT CAN
N
DKG throttle valve sensor error
- Check/replace DKG throttle valve sensor ECU
none
Bus active
Rough shifting
0xCDB8
52664
Message 0xB8 (twin-clutch transmission)
No Info.
No Info.
No new messages
295 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>295 ms
none
PT CAN
N
DKG throttle valve sensor error, wiring harness
- Check plug and wiring harness to throttle valve sensor DKG
- Check/replace DKG ECU
none
Bus active
Rough shifting
0xCDBB
52667
Message 0xCE (wheel speeds)
No Info.
No Info.
80 (K_ED_PT_VRAD.ERROR THRESHOLD)
795 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>795 ms
none
PT CAN
N
Internal DME ECU fault
- Replace DME ECU
none
Bus active
CC status report: DSC failure / DSC lamp
0x27E8
10216
EWS4 Secret Key Memory
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
EWS4 Status
none
N
All 3 Secret Key stations occupied
Replace control module
none
Cannot occur in field, only relevant for factory
No engine start possible
0x27E9
10217
EWS4 manipulation
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
EWS4 Status
none
N
Flash write/read error
Replace control module
none
No EWS4 enable
No engine start possible
0x27EA
10218
EWS4 CAS communication
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
none
none
N
Open wire (D_EWS4) DME - CAS
Check the connection between D_EWS4 DME ECU and CAS ECU, repair open wire, clear fault memory
none
Standard engine operation, as redundant signal transmission is expedited via CAN bus
none
0x27EC
10220
EWS4 internal fault
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x27E8
10216
EWS4 Secret Key Memory
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
EWS4 Status
none
N
Flash writing error
Replace control module
none
Cannot occur in field, only relevant for factory
No engine start possible
0x27E9
10217
EWS4 manipulation
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
EWS4 Status
none
N
No secret key yet programmed
Factory: Program secret key / Service: Replace control module
none
No EWS4 enable
No engine start possible
0x27EA
10218
EWS4 CAS communication
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
none
none
N
Open wire (D_EWS4) DME - CAS
Check the connection between D_EWS4 DME ECU and CAS ECU, repair open wire, clear fault memory
none
Standard engine operation, as redundant signal transmission is expedited via CAN bus
none
0x27EB
10219
EWS4 CAN communication
No Info.
No Info.
none
none
Terminal 15
Battery voltage > 9 V
none
none
none
none
N
Problem with CAN link
Check PT CAN communications with DME SD, check K CAN communications with CAS ECU, clear fault memory
none
Standard engine operation, as redundant signal transmission is expedited via CAS bus
none
0x27EC
10220
EWS4 internal fault
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0x27E8
10216
EWS4 Secret Key Memory
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
EWS4 Status
none
N
Flash writing error
Replace control module
none
Cannot occur in field, only relevant for factory
No engine start possible
0x27E9
10217
EWS4 manipulation
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
EWS4 Status
none
N
Flash write/read error
Replace control module
none
No EWS4 enable
No engine start possible
0x27EA
10218
EWS4 CAS communication
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
none
none
N
Open wire (D_EWS4) DME - CAS
- DME software release must be more recent than 07--06--510, fix incorporated starting with 08--03--500
- Check connection between D_EWS4 DME ECU and CAS ECU
- Repair open wire
- Clear fault memory
none
Standard engine operation, as redundant signal transmission is expedited via CAN bus
none
0x27EB
10219
EWS4 CAN communication
No Info.
No Info.
none
none
Terminal 15
Battery voltage > 9 V
none
none
none
none
N
Problem with CAN link
- DME software release must be more recent than 07--06--510, fix incorporated since 08--03--500
- Check PT CAN communications with DME ECU
- Check K CAN communications with CAS ECU
- Clear fault memory
none
Standard engine operation, as redundant signal transmission is expedited via CAS bus
none
0x27EC
10220
EWS4 internal fault
No Info.
No Info.
none
none
Terminal 15
Battery voltage > 9 V
none
none
none
none
Y
Internal DME
Replace DME ECU
none
No EWS4 enable
Engine start not possible
0x27E7
10215
Limp-home operation, 100 % el. fuel pump activation
No Info.
No Info.
pks_can_diag_st == EKP_BEMF_FEHLER
1
none
none
none
>10 ms
none
none
Y
Fuel pump RPM signal cannot be assessed by electric fuel pump module
- Use tester to trigger electric fuel pump module at 100 % pulse-duty factor
- If error is logged and pump runs - replace electric fuel pump module
- If error is logged and pump does not run - replace pump
MIL, CC message
Diagnosis running in electric fuel pump module
CC status report
0x27E8
10216
EWS4 Secret Key Memory
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
EWS4 Status
none
N
Flash write/read error
Replace control module
none
Cannot occur in field, only relevant for factory
No engine start possible
0x27E9
10217
EWS4 manipulation
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
EWS4 Status
none
N
Response error
Factory: Program same secret key for DME ECU and CAS Car Access System ECU / Service: Replace control module
none
No EWS4 enable
Engine start not possible
0x27EA
10218
EWS4 CAS communication
No Info.
No Info.
none
none
K15
Battery voltage > 9 V
none
none
none
none
N
Open wire (D_EWS4) DME - CAS
Check the connection between D_EWS4 DME ECU and CAS ECU, repair open wire, clear fault memory
none
Standard engine operation, as redundant signal transmission is expedited via CAN bus
none
0x27EC
10220
EWS4 internal fault
No Info.
No Info.
none
none
Terminal 15
Battery voltage > 9 V
none
none
none
none
Y
Internal DME
Factory: Program secret key again, clear fault memory
none
Normal engine operation, but DME ECU is not protected against manipulation through debugger interface
Engine start possible
0xCD94
52628
Message 0x310 (outside temperature)
Communication
Ambient Temperature/Relative Time
100 (K_ED_PT_ATEMP.ERROR THRESHOLD)
19900 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>19900 ms
none
PT CAN
N
Internal DME ECU fault
- Replace SGM ECU
MIL
Bus active
Outside temperature display failed
0xCD95
52629
Message 0x194 (operation cruise control)
No Info.
No Info.
No new messages
100 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
1000 ms
none
PT CAN
N
Internal DME ECU fault
- Replace DME ECU
CC status report
Bus active
FGR cruise control inoperative / possible CC message-FGR failure
0xCD94
52628
Message 0x310 (outside temperature)
Communication
Ambient Temperature/Relative Time
No new messages
19900 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>19900 ms
none
PT CAN
N
No power supply to SGM security and gateway module ECU / open wire SGM-CAN / CAN wire defective / defective I-cluster
- Check plug and wiring harness at security gateway module SGM ECU
- Replace security gateway module SGM ECU
MIL
Bus active
Outside temperature display failed
0xCD98
52632
Message 0xB6 (torque request DSC)
No Info.
No Info.
80 (K_ED_PT_TORQDSC.ERROR THRESHOLD)
495 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>495 ms
none
PT CAN
N
Internal error in DME ECU / DME or DSC fault
- Replace DME ECU
DSC, CC message
Bus active
CC status report: DSC failure / DSC lamp
0xCD95
52629
Message 0x194 (operation cruise control)
No Info.
No Info.
Alive error > 5 (K_CAN_ALIVE_ERR_MAX)
100 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
1000 ms
none
PT CAN
N
Internal malfunction in SZL steering column switch center ECU / malfunction in DME or sensor
- Check plug and wiring harness to SZL steering column switch center ECU
- Replace SZL ECU
CC status report
Bus active
FGR cruise control inoperative / possible CC message-FGR failure
0xCD95
52629
Message 0x194 (operation cruise control)
No Info.
No Info.
No new messages
100 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
1000 ms
none
PT CAN
N
No power supply to SZL steering column switch center ECU / open wire between SZL-CAN / defective sensor
- Check plug and wiring harness to SZL steering column switch center ECU
- Replace SZL ECU
CC status report
Bus active
FGR inoperative / possible CC message-FGR cruise control failure
0xCD95
52629
Message 0x194 (operation cruise control)
No Info.
No Info.
Checksum error > 5 (K_CAN_CHKSUM_ERR_MAX)
100 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
1000 ms
none
PT CAN
N
Internal malfunction in SZL steering column switch center ECU / Malfunction in DME or sensor
- Check plug and wiring harness to SZL steering column switch center ECU
- Replace SZL ECU
CC status report
Bus active
FGR cruise control inoperative / possible CC message-FGR failure
0xCD9B
52635
Message 0x315 (vehicle mode)
No Info.
No Info.
none
none
none
none
none
none
none
PT CAN
N
Internal DME ECU fault
none
none
No Info.
0xCD9C
52636
Message 0x1A0 (vehicle speed)
No Info.
No Info.
80 (K_ED_PT_VFZG.ERROR THRESHOLD)
795 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>795 ms
none
PT CAN
N
Internal DME ECU fault
- Replace DME ECU
none
Bus active
CC status report: DSC failure / DSC lamp
0xCD9B
52635
Message 0x315 (vehicle mode)
No Info.
No Info.
none
none
none
none
none
none
none
PT CAN
N
Internal SGM security and gateway module ECU malfunction
none
none
No Info.
0xCD9C
52636
Message 0x1A0 (vehicle speed)
No Info.
No Info.
Checkum error for 5 (K_CAN_CHKSUM_ERR_MAX) cycles
795 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>795 ms
none
PT CAN
N
Internal malfunction in DSC ECU or internal malfunction in DME ECU
- Replace DSC ECU
none
Bus active
CC status report: DSC failure / DSC lamp
0xCD9B
52635
Message 0x315 (vehicle mode)
No Info.
No Info.
none
none
none
none
none
none
none
PT CAN
N
No power supply to SGM security and gateway module ECU / open wire between SGM-CAN
none
none
No Info.
0xCD98
52632
Message 0xB6 (torque request DSC)
No Info.
No Info.
Alive counter stops for 5 (K_CAN_ALIVE_ERR_MAX) cycles
395 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>395 ms
none
PT CAN
N
Internal DSC ECU malfunction
- Replace DSC ECU
DSC, CC message
Bus active
CC status report: DSC failure / DSC lamp
0xCD9B
52635
Message 0x315 (vehicle mode)
No Info.
No Info.
none
none
none
none
none
none
none
PT CAN
N
Internal SGM security and gateway module ECU malfunction
none
none
No Info.
0xCD98
52632
Message 0xB6 (torque request DSC)
No Info.
No Info.
No new messages
495 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>495 ms
none
PT CAN
N
No power to DSC ECU/open wire between DSC-CAN, internal DSC ECU malfunction / defective CAN wire, DSC defective
- Check plug and wiring harness at DSC
- Replace DSC control module
DSC, CC message
Bus active
CC status report: DSC failure / DSC lamp
0xCD98
52632
Message 0xB6 (torque request DSC)
No Info.
Checksum error for 5 (K_CAN_CHKSUM_ERR_MAX) cycles
395 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>395 ms
none
PT CAN
N
Internal error in DME ECU / DME or DSC fault
- Replace DSC ECU
DSC, CC message
Bus active
CC status report: DSC failure / DSC lamp
No Info.
0xCD9D
52637
Message 0xBA (transmission data)
No Info.
No Info.
80 (K_ED_PT_GRB.ERROR THRESHOLD)
225 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>225 ms
none
PT CAN
N
Internal DME ECU fault
- Replace DME ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCD9E
52638
Message 0x1A2 (transmission data 2)
No Info.
No Info.
80 (K_ED_PT_GRB.ERROR THRESHOLD)
140 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>140 ms
none
PT CAN
N
Internal DME ECU fault
- Replace DME ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCD9D
52637
Message 0xBA (transmission data)
No Info.
No Info.
Checkum error for 5 (K_CAN_CHKSUM_ERR_MAX) cycles
225 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>225 ms
none
PT CAN
N
Internal malfunction in DKG throttle valve sensor ECU or in DME ECU
- Replace DKG throttle valve sensor ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCD9E
52638
Message 0x1A2 (transmission data 2)
No Info.
No Info.
Checkum error for 5 (K_CAN_CHKSUM_ERR_MAX) cycles
700 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>700 ms
none
PT CAN
N
Internal malfunction in DKG throttle valve sensor ECU or in DME ECU
- Replace DKG throttle valve sensor ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCD9C
52636
Message 0x1A0 (vehicle speed)
Communication
Speed
No new messages
795 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>795 ms
none
PT CAN
N
No power supply to DSC ECU/open wire DSC-CAN, internal malfunction in DSC ECU
- Check plug and wiring harness at DSC ECU
- Replace DSC control module
none
Bus active
CC message-DSC error and FGR cruise control not operating / DSC lamp
0xCD9D
52637
Message 0xBA (transmission data)
No Info.
No Info.
No new messages
395 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>395 ms
none
PT CAN
N
No power supply to DKG throttle valve sensor ECU/ Open wire DKG-CAN, internal fault in DKG throttle valve sensor ECU
- Check plug and wiring harness at DKG throttle valve sensor ECU
- Replace DKG throttle valve sensor ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCD9E
52638
Message 0x1A2 (transmission data 2)
No Info.
No Info.
No new messages
140 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>140 ms
none
PT CAN
N
No power supply to DKG throttle valve sensor ECU/ Open wire DKG-CAN, internal fault in DKG throttle valve sensor ECU
- Check plug and wiring harness at DKG throttle valve sensor ECU
- Replace DKG throttle valve sensor ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCD9C
52636
Message 0x1A0 (vehicle speed)
No Info.
No Info.
Alive counter stops for 5 (K_CAN_ALIVE_ERR_MAX) cycles
795 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>795 ms
none
PT CAN
N
Internal DSC ECU malfunction
- Replace DSC ECU
none
Bus active
CC status report: DSC failure / DSC lamp
0xCD9D
52637
Message 0xBA (transmission data)
No Info.
No Info.
Alive counter stops for 5 (K_CAN_ALIVE_ERR_MAX) cycles
225 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>225 ms
none
PT CAN
N
Internal DKG throttle valve sensor ECU fault
- Replace DKG throttle valve sensor ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCD9E
52638
Message 0x1A2 (transmission data 2)
No Info.
No Info.
Alive counter stops for 5 (K_CAN_ALIVE_ERR_MAX) cycles
140 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>140 ms
none
PT CAN
N
Internal DKG throttle valve sensor ECU fault
- Replace DKG throttle valve sensor ECU
none
Bus active
CC message error, DKG throttle valve sensor not operating / DKG lamp
0xCD9F
52639
Message 0x330 (kilometre reading)
No Info.
No Info.
No new messages
119000 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>119000 ms
none
PT CAN
N
No power supply to SGM security and gateway module ECU / open wire SGM-CAN / CAN wire defective, defective sensor
- Check plug and wiring harness at security gateway module SGM ECU
- Replace security gateway module SGM ECU
none
Bus active
All displays in instrument cluster stop operating
0xCDA1
52641
Message 0xC4 (steering angle)
No Info.
No Info.
100 (K_ED_PT_LRW.ERROR THRESHOLD)
395 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>395 ms
none
PT CAN
N
Internal DME ECU fault
- Replace DSC ECU
none
Bus active
CC message-DSC error and FGR cruise control not operating / DSC lamp
0xCDA0
52640
Message 0x130 (terminal status)
No Info.
No Info.
Alive counter stops for 5 (K_CAN_ALIVE_ERR_MAX) cycles
800 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>800 ms
none
PT CAN
N
SGM security and gateway module ECU internal fault / Fault with DME or DSC
- Replace SGM ECU
none
Bus active
All displays in instrument cluster stop operating
0xCDA0
52640
Message 0x130 (terminal status)
No Info.
No Info.
No new messages
1500 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>1500 ms
none
PT CAN
N
No power supply to SGM security and gateway module ECU / open wire SGM-CAN / CAS /ZGM
- Check plug and wiring harness at security gateway module SGM ECU
- Replace security gateway module SGM ECU
none
Bus active
All displays in instrument cluster stop operating
0xCDA0
52640
Message 0x130 (terminal status)
No Info.
No Info.
Checkum error for 5 (K_CAN_CHKSUM_ERR_MAX) cycles
800 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>800 ms
none
PT CAN
N
Internal fault in SGM security and gateway module ECU / DME fault / CAS / ZGM
- Replace SGM ECU
none
Bus active
All displays in instrument cluster stop operating
0xCDA1
52641
Message 0xC4 (steering angle)
No Info.
No Info.
No new messages
395 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>395 ms
none
PT CAN
N
No power supply to LWS latent warmth storage / open wire LWS-CAN / defect in CAN wire / LWS defective
- Check plug and wiring harness on LWS and DSC ECU
- Replace LWS
- Replace DSC ECU
none
Bus active
CC message-DSC error and FGR cruise control not operating / DSC lamp
0xCDA5
52645
Message 0x19E (status DSC)
No Info.
No Info.
80 (K_ED_PT_STDSC.ERROR THRESHOLD)
795 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>795 ms
none
PT CAN
N
Internal DME ECU fault
- Replace DME ECU
MIL
Bus active
CC status report: DSC failure / DSC lamp
0xCDA5
52645
Message 0x19E (status DSC)
No Info.
No Info.
No new messages
795 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>795 ms
none
PT CAN
N
No power supply to DSC ECU/open wire DSC-CAN, internal malfunction in DSC ECU
- Check plug and wiring harness at DSC
- Replace DSC control module
MIL
Bus active
CC message-DSC error and FGR cruise control not operating / DSC lamp
0xCDA7
52647
Message 0x3B0 (status, reverse gear)
No Info.
No Info.
No new messages
15 sec.
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>15 sec.
none
PT CAN
N
No power supply to FRMFA ECU/K or PT CAN has open wire, internal error in FRMFA ECU / Defective CAN wire, defective FRMFA
- Check plug and wiring harness on FRMFA
- Replace FRMFA ECU
none
Bus active
Cannot be felt
0xCDA8
52648
Message 0x1B4 (status, instrument cluster)
Communication
Instrument Pack
Alive error > 5 (K_CAN_ALIVE_ERR_MAX)
500 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>500 ms.
none
PT CAN
N
SGM security and gateway module ECU internal fault / malfunction in sensor or DME
- Replace SGM ECU
MIL
Bus active
All displays in instrument cluster stop operating
0xCDA8
52648
Message 0x1B4 (status, instrument cluster)
Communication
Instrument Pack
No new messages
100 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>100 ms
none
PT CAN
N
Internal DME ECU fault
- Replace DME ECU
MIL
Bus active
All displays in instrument cluster stop operating
0xCDA8
52648
Message 0x1B4 (status, instrument cluster)
Communication
Instrument Pack
No new messages
700 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>700 ms
none
PT CAN
N
No power supply to SGM security and gateway module ECU / open wire SGM-CAN / CAN wire defective, defective sensor
- Check plug and wiring harness at security gateway module SGM ECU
- Replace security gateway module SGM ECU
MIL
Bus active
All displays in instrument cluster stop operating
0xCDAA
52650
Message 0x135 (crash deactivation)
No Info.
No Info.
No new messages
70 sec.
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>70 sec.
none
PT CAN
N
No power supply ACSM ECU / open wire ACSM-CAN, internal malfunction in ACSM ECU
- Check plug and wiring harness on ACSM ECU
- Replace ACSM ECU
none
Bus active
Cannot be felt
0xCDA9
52649
Message 0x1B5 (A/C request)
No Info.
No Info.
No new messages
39000 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>39000 ms
none
PT CAN
N
No power supply to IHKA ECU / open wire KKOS-CAN / CAN wire defect / defective a/c
- Check plug and wiring harness to a/c ECU
- Replace a/c ECU
none
Bus active
Air conditioner does not operate
0xCDAA
52650
Message 0x135 (crash deactivation)
No Info.
No Info.
No new messages
none
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
none
none
PT CAN
N
No power supply to SGM security and gateway module ECU / open wire between SGM-CAN
- Check plug and wiring harness on SGM security and gateway module ECU
- Check SI bus
- Replace SGM ECU
none
none
Driver does not notice
0xCDBC
52668
Message 0x1D6 (operation, M-Drive button)
No Info.
No Info.
Checksum error > K_CAN_CHKSUM_ERR_MAX
8000 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>8000 ms
none
PT CAN
N
Internal malfunction in SGM security gateway module ECU / sensor or DME malfunction
- Check plug and wiring harness at security gateway module SGM ECU
- Replace security gateway module SGM ECU
none
none
Operational failure of mobile phone controls / M-Drive
0xCDBB
52667
Message 0xCE (wheel speeds)
No Info.
No Info.
No new messages
795 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>795 ms
none
PT CAN
N
No power supply to DSC ECU/open wire DSC-CAN, internal malfunction in DSC ECU
- Check plug and wiring harness at DSC
- Replace DSC control module
none
Bus active
CC message-DSC error and FGR cruise control not operating / DSC lamp
0xCDBC
52668
Message 0x1D6 (operation, M-Drive button)
No Info.
No Info.
No new messages
13000 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>13000 ms
none
PT CAN
N
No power supply to SGM ECU / open wire between SGM-CAN /defective sensor
- Check plug and wiring harness at security gateway module SGM ECU
- Replace security gateway module SGM ECU
none
none
Operational failure of mobile phone controls / M-Drive
0xCDBC
52668
Message 0x1D6 (operation, M-Drive button)
No Info.
No Info.
Alive error > K_CAN_ALIVE_ERR_MAX
8000 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
none
>8000 ms
none
PT CAN
N
Internal malfunction in SGM security gateway module ECU / sensor or DME malfunction
- Check plug and wiring harness at security gateway module SGM ECU
- Replace security gateway module SGM ECU
none
none
Operational failure of mobile phone controls / M-Drive
0xCDBD
52669
Idle actuator CAN message, bank 1
No Info.
No Info.
No new messages
150 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>150 ms
LLS test routine
CAN LLS/electric fuel pump
N
No messages / open CAN or power supply wires, or wires shorted to positive or ground
- Clear fault memory, LLS system test
- Check fuse, plug and wiring harness at LLS1, check SMG ECU and DME
- Replace LLS1
MIL, EML, CC message, backup program
none
DSC lamp / CC message / engine speed limited to 5000 RPM / reduced power / engine start may be possible only with use of accelerator pedal
0xCDBE
52670
Message 0x1A3 (longitudinal acceleration)
No Info.
No Info.
No Info.
700 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
No Info.
>700 ms
none
PT CAN
N
Internal DME ECU fault
- Replace DME ECU
none
No Info.
No Info.
0xCDBE
52670
Message 0x1A3 (longitudinal acceleration)
No Info.
No Info.
No Info.
700 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
No Info.
>700 ms
none
PT CAN
N
Internal malfunction in DSC ECU or internal malfunction in DME ECU
- Replace DSC ECU
none
No Info.
No Info.
0xCDBE
52670
Message 0x1A3 (longitudinal acceleration)
No Info.
No Info.
No Info.
700 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
No Info.
>700 ms
none
PT CAN
N
No power supply to DSC ECU/open wire DSC-CAN, internal malfunction in DSC ECU
- Check plug and wiring harness on throttle valve sensor DKG ECU
- Check cluster sensor
- Replace DSC ECU
none
No Info.
No Info.
0xCDBD
52669
Idle actuator CAN message, bank 1
No Info.
No Info.
Alive error > K_CAN_ALIVE_ERR_MAX
50 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>50 ms
LLS test routine
CAN LLS/electric fuel pump
N
Internal ECU error - counter error
- Clear fault memory, LLS system test
- Check fuse, plug and wiring harness at LLS1, check SMG ECU and DME
- Replace LLS1
MIL, EML, CC message, backup program
none
DSC lamp / CC message / engine speed limited to 5000 RPM / reduced power / engine start may be possible only with use of accelerator pedal
0xCDBE
52670
Message 0x1A3 (longitudinal acceleration)
No Info.
No Info.
No Info.
700 ms
Terminal 15
Battery voltage > 9V (k_can_ed_ub_min)
No Info.
>700 ms
none
PT CAN
N
Internal DSC ECU malfunction
- Replace DSC ECU
none
No Info.
No Info.
0xCDBD
52669
Idle actuator CAN message, bank 1
No Info.
No Info.
Checksum error > K_CAN_CHKSUM_ERR_MAX
50 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>50 ms
LLS test routine
CAN LLS/electric fuel pump
N
Internal control module malfunction
- Clear fault memory, LLS idle actuator system test
- Program DME
- Replace DME
MIL, EML, CC message, backup program
none
DSC lamp / CC message / engine speed limited to 5000 RPM / reduced power / engine start may be possible only with use of accelerator pedal
0xCDBD
52669
Idle actuator CAN message, bank 1
No Info.
No Info.
No new messages
10 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>10 ms
LLS test routine
CAN LLS/electric fuel pump
N
Internal control module malfunction
- Clear fault memory, LLS idle actuator system test
- Program DME
- Replace DME
MIL, EML, CC message, backup program
none
DSC lamp / CC message / engine speed limited to 5000 RPM / reduced power / engine start may be possible only with use of accelerator pedal
0xCD8B
52619
Bus Off idle-controller CAN
No Info.
No Info.
Bus-off from CAN driver
150 ms
Wakeup
max (ub, u_wakeup) <= K_SMG_CAN_ED_UB_MIN
none
>150 ms
LLS test routine
CAN LLS/electric fuel pump
N
SMG-CAN wire / short to ground / short to battery voltage
- Clear fault memory, LLS idle actuator system test
- Check wiring harness at LLS1 and LLS2, check SMG ECU and DME
- Disconnect SMG ECU, clear fault memory, perform LLS idle actuator system test
- Disconnect LLS individually and clear fault memory, perform LLS system test
MIL, EML, CC message, backup program
Bus active && (egas_can_ed_tsperr_lls == 0)
DSC lamp/ CC message/power reduction/high idle/displayed RPM limit at 2500 RPM/poor throttle response/ MIL after engine runs 2x
0xCD93
52627
Bus Off throttle-valve CAN
No Info.
No Info.
Bus-off from CAN driver
150 ms
Wakeup
max (ub, u_wakeup) <= K_SMG_CAN_ED_UB_MIN
none
>150 ms
DK test routine
CAN DK throttle valve
N
DK CAN wire shorted to ground / short to battery voltage
- Clear fault memory, EDR system test
- Check wiring harness to EDR1, EDR2 and DME
MIL, EML, CC message, backup program
Bus active && (egas_can_ed_tsperr_lls == 0)
CC message RPM limited Power reduction DSC lamp
0xCDBF
52671
Throttle-valve actuator CAN message, bank 1
No Info.
No Info.
No new messages
150 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>150 ms
DK test routine
CAN DK throttle valve
N
No messages / open CAN or power supply wires, or wires shorted to positive or ground
- Clear fault memory, EDR electronic throttle valve system test
- Check fuse, plug and wiring harness at EDR1 and DME
- Replace EDR 1
MIL, EML, CC message, backup program
none
CC message Engine speed limited Reduced power MIL after engine runs 2x
0xCDBF
52671
Throttle-valve actuator CAN message, bank 1
No Info.
No Info.
Alive error > K_CAN_ALIVE_ERR_MAX
50 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>50 ms
DK test routine
CAN DK throttle valve
N
Internal ECU error - counter error
- Clear fault memory, EDR electronic throttle valve system test
- Check fuse, plug and wiring harness at EDR1 and DME
- Replace EDR 1
MIL, EML, CC message, backup program
none
CC message Engine speed limited Reduced power MIL after engine runs 2x
0xCDBF
52671
Throttle-valve actuator CAN message, bank 1
No Info.
No Info.
No new messages
10 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>10 ms
DK test routine
CAN DK throttle valve
N
Internal control module malfunction
- Clear fault memory, EDR electronic throttle valve system test
- Program DME
- Replace DME
MIL, EML, CC message, backup program
none
CC message Engine speed limited Reduced power MIL after engine runs 2x
0xCDBF
52671
Throttle-valve actuator CAN message, bank 1
No Info.
No Info.
Checksum error > K_CAN_CHKSUM_ERR_MAX
50 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>50 ms
DK test routine
CAN DK throttle valve
N
Internal control module malfunction
- Clear fault memory, EDR electronic throttle valve system test
- Check fuse, plug and wiring harness at EDR1 and DME
- Replace EDR 1
MIL, EML, CC message, backup program
none
CC message Engine speed limited Reduced power
0xCDC0
52672
CDBD Throttle-valve actuator CAN message, bank 2
No Info.
No Info.
No new messages
150 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>150 ms
DK test routine
CAN DK throttle valve
N
No messages / open CAN or power supply wires, or wires shorted to positive or ground
- Clear fault memory, EDR electronic throttle valve system test
- Check fuse, plug and wiring harness at EDR2 and DME
- Replace EDR2
MIL, EML, CC message, backup program
none
CC message Engine speed limited Reduced power MIL after engine runs 2x
0xCDC1
52673
Message 0x580--0x5FF (CAS response)
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0xCDC1
52673
Message 0x580--0x5FF (CAS response)
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0xCDC2
52674
Message 0x580--0x5FF (OBD fault class)
No Info.
No Info.
No new messages
80s
Terminal 15
Battery voltage >9 V
none
>80s
none
PT CAN
N
No new messages
- Check plug and wiring harness at I-cluster
- Replace I-cluster ECU
none
none
Cannot be felt
0xCDC3
52675
Message 0x374 (wheel-tolerance calibration)
No Info.
No Info.
No new messages
700 ms
Wakeup
Battery voltage > 9V (k_can_ed_ub_min)
none
>700 ms
none
PT CAN
N
No power to DSC ECU/open wire between DSC-CAN, internal DSC ECU malfunction / defective CAN wire, DSC defective
- Check plug and wiring harness at DSC
- Replace DSC control module
none
Bus active
Cannot be felt
0xCDC0
52672
CDBD Throttle-valve actuator CAN message, bank 2
No Info.
No Info.
Alive error > K_CAN_ALIVE_ERR_MAX
50 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>50 ms
DK test routine
CAN DK throttle valve
N
Internal ECU error - counter error
- Clear fault memory, EDR electronic throttle valve system test
- Check fuse, plug and wiring harness at EDR2 and DME
- Replace EDR2
MIL, EML, CC message, backup program
none
CC message Engine speed limited Reduced power MIL after engine runs 2x
0xCDC1
52673
Message 0x580--0x5FF (CAS response)
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
No Info.
0xCDC0
52672
CDBD Throttle-valve actuator CAN message, bank 2
No Info.
No Info.
No new messages
10 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>10 ms
DK test routine
CAN DK throttle valve
N
Internal control module malfunction
- Clear fault memory, EDR electronic throttle valve system test
- Program DME
- Replace DME
MIL, EML, CC message, backup program
none
CC message Engine speed limited Reduced power MIL after engine runs 2x
0xCDC0
52672
CDBD Throttle-valve actuator CAN message, bank 2
No Info.
No Info.
Checksum error > K_CAN_CHKSUM_ERR_MAX
50 ms
TERM87
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
none
>50 ms
DK test routine
CAN DK throttle valve
N
Internal control module malfunction
- Clear fault memory, EDR electronic throttle valve system test
- Program DME
- Replace DME
MIL, EML, CC message, backup program
none
CC message Engine speed limited Reduced power