Contents Wiring diagrams Section: Hydraulic Components - Brake System All sections

VACUUM, CHECKING Audi Q5 I

Hydraulic Components - Brake System 1 illustration ~222 words

VACUUM, CHECKING

Special tools and workshop equipment required

  1. Brake Servo Tester VAS 6721
  2. Hand Vacuum Pump VAS 6213

Note. The average earth atmospheric air pressure at sea level (N. N.) is 1013 mbar and it decreases dramatically at higher altitudes (approximately 100 mbar every 1000 meters higher) Local and time fluctuations will influence the vacuum. A cold engine, the A/C switched being on and even only the engine idling can negatively influence the vacuum.

Check all the vacuum hoses beforehand for damage (for example, tears or damaged caused by animals) and make sure they are secure.

Connect the VAS 6721. Refer to Brake Servo Tester VAS 6721, CONNECTING .

Open the shut-off valve -A-.

Close the shut-off valves -B+C-.

Scheme 11

Scheme 11

Start the warm (above 60° C) engine and press the accelerator pedal one time quickly (engine RPM higher than 2, 000).

Read the measured value displayed.

Normally (see note) the vacuum should be between 600 and 950 mbar (depending on the engine installed).

Check the vacuum system for leaks if the measured value is not reached, even though all requirements (see notes).

Create the vacuum using a VAS 6213 for comparison purposes. Refer to VACUUM, CREATING USING Hand Vacuum Pump VAS 6213 .

Opening the shut-off valve -B- makes it easier to remove the hose connections and the adapter.