Contents Wiring diagrams Section: 2.0l - Cooling System - Engine Code(s): Caeb (avant) All sections

RADIATOR FAN CONTROL MODULE Audi A4 B8

RADIATOR FAN CONTROL MODULE

Removing

Note. During installation, all cable ties must be installed at the same location.

Remove the noise insulation. Refer to Description and Operation .

Remove the coolant fan electrical connector -1- from the bracket and disconnect it by sliding the retainer back -arrow- and pressing the release down.

Free up the electrical wiring harness to the radiator fan control module.

Disconnect electrical connectors -2- and -3-.

Scheme 106

Scheme 106

Remove the bolt -arrow- and the coolant fan control module -1-.

Installing

Install in reverse order of removal. Note the following

  1. Tightening specifications, refer to «RADIATOR AND RADIATOR FAN OVERVIEW»(/audi/a4/b8-2007-2012/remont/cooling-fan/#20l-cooling-system-engine-codes-caeb-avant__radiator-and-radiator-fan-overview) .

Install the front noise insulation. Refer to Description and Operation .