INTRODUCTION
Mode 6 is designed to allow access to the results of onboard diagnostic monitoring tests of specific components/systems that are not continuously monitored. These systems include the catalytic converter, EVAP system, oxygen sensor, oxygen sensor heater, EGR system, secondary AIR system, and sometimes misfire.
Mode 6 data is output from the PCM/ECM in hexadecimal form. The $ sign indicates a hexadecimal number. Depending on the software in the scanner, the output could be displayed in hexadecimal numbers (no conversion), raw data (conversion to decimal numbers), or measurable values (applying conversion factor to raw data).
Before reading mode 6 information, ensure that the monitor for the information you are accessing has run to completion. If the monitor is not complete, the mode 6 data will not be accurate.
Mode $06 Test ID by Model
| Monitor | Test ID | Test Limit Type and Comp. ID | 3.2 TL | 3.2 CL | MDX | 3.5 RL | NSX | RSX |
|---|---|---|---|---|---|---|---|---|
| EGR Flow Rate | $01 | $80 | X | X | X | X | X | |
| Catalyst (Bank 1) | $04 | $02 | X | |||||
| $05/$06 | $81/$81 | X | X | X | X | X | ||
| $06 | $80 | |||||||
| Catalyst (Bank 2) | $07 | $80 | ||||||
| $07/$0A | $81/$81 | X | ||||||
| PHO2S Heater (Bank 1) | $10/$11 | $80/$00 | ||||||
| $10/$11 | $81/$01 | |||||||
| $10/$11 | $84/$04 | |||||||
| $10/$11 | $85/$05 | X | ||||||
| $10/$11 | $86/$06 | X | X | X | X | |||
| $10/$11 | $87/$07 | |||||||
| PHO2S Heater (Bank 2) | $12/$13 | $81/$01 | X | |||||
| $12/$13 | $85/$05 | X | ||||||
| $12/$13 | $86/$06 | |||||||
| A/F Ratio Sensor Heater | $0E | $00 | X | |||||
| SHO2S Heater (Bank 1) | $18/$19 | $80$00 | ||||||
| $18/$19 | $81/$01 | |||||||
| $18/$19 | $85/$05 | |||||||
| $18/$19 | $86/$06 | X | X | X | X | X | X | |
| $18/$19 | $87/$07 | |||||||
| $18/$19 | $88/$08 | |||||||
| SHO2S Heater (Bank 2) | $1A/$1B | $81/$01 | ||||||
| $1A/$1B | $86/$06 | X | X | |||||
| EVAP System for tank leak check | $21/$26/$27 | $81/$81/$81 | X (1) | X | X | X | ||
| $21/$26/$27/$38/$3A/$3B/$3C | $82/$82/$82/$02/$82/$82/$02 | X (2) | X | X | ||||
| EVAP System for canister leak check | $29/$2D/$2E/$2F | $81/$01/$81/$81 | X (1) | X | X | X | ||
| $29/$2D/$2E/$2F/$3E | $82/$02/$82/$82/$82 | X (2) | X | X | ||||
| Thermostat | $4D/$4E/$4F/$50 | $80/$80/$80/$00 | X | X | ||||
| $5C/$5D/$5E/$5F | $00/$00/$00/$00 | X | X | X | X | |||
| Secondary Air System | $58/$59/$5A | $80/$00/$80 | X | |||||
| (1) LEV (2) ULEV | ||||||||
| (1) | LEV |
| (2) | ULEV |
Mode $06 Test ID by Model
EGR Flow Rate
| Test ID | $01 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0401 | ||
| Test Description | Check EGR flow by monitoring the change in intake manifold pressure between EGR valve open and closed during fuel cut. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 1.34 (mmHg) The lowest limit value: Output value (Decimal) x 1.34 (mmHg) The highest limit value: Not applicable | ||
DTC P0401: Test ID $01: Component ID $80
Catalyst (Bank 1)
| Test ID | $04 | Test Limit Type and Component ID | $02 |
|---|---|---|---|
| DTC | P0420 | ||
| Test Description | Catalyst capability, monitored by measuring the fluctuation of the secondary oxygen sensor output value. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: No unit The lowest limit value: Not applicable The highest limit value: No unit | ||
DTC P0420: Test ID $04: Component ID $02
| Test ID | $05 | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P0420 | ||
| Test Description | Catalyst capability monitored by OSC index. OSC index is calculated from the secondary oxygen sensor signal during the secondary oxygen sensor feedback control. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: No unit The lowest limit value: No unit The highest limit value: Not applicable | ||
DTC P0420: Test ID $05: Component ID $81
| Test ID | $06 | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P0420 | ||
| Test Description | Catalyst capability monitored by the secondary oxygen sensor signal during the secondary oxygen sensor feedback control. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 10 (msec.) The lowest limit value: Output value x 10 (msec.) The highest limit value: Not applicable | ||
DTC P0420: Test ID $05: Component ID $81
Catalyst (Bank 2)
| Test ID | $07 | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P0420 | ||
| Test Description | Catalyst capability monitored by the secondary oxygen sensor signal during the secondary oxygen sensor feedback control. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 10 (msec.) The lowest limit value: Output value x 10 (msec.) The highest limit value: Not applicable | ||
DTC P0420: Test ID $07: Component ID $81
| Test ID | $0A | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P0430 | ||
| Test Description | Catalyst capability monitored by measuring the fluctuation of the secondly oxygen sensor output value. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: No unit The lowest limit value: No unit The highest limit value: Not applicable | ||
DTC P0430: Test ID $0A: Component ID $81
PHO2S Heater (Bank 1)
| Test ID | $10 | Test Limit Type and Component ID | $85 |
|---|---|---|---|
| DTC | P0135 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 26.7 (mA) The lowest limit value: Output value x 26.7 (mA) The highest limit value: Not applicable | ||
DTC P0135: Test ID $10: Component ID $85
| Test ID | $11 | Test Limit Type and Component ID | $05 |
|---|---|---|---|
| DTC | P0135 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 26.7 (mA) The lowest limit value: Not applicable The highest limit value: Output value x 26.7 (mA) | ||
DTC P0135: Test ID $11: Component ID $05
| Test ID | $10 | Test Limit Type and Component ID | $86 |
|---|---|---|---|
| DTC | P0135 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 7.23 (mA) The lowest limit value: Output value x 7.23 (mA) The highest limit value: Not applicable | ||
DTC P0135: Test ID $10: Component ID $86
| Test ID | $11 | Test Limit Type and Component ID | $06 |
|---|---|---|---|
| DTC | P0135 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 7.23 (mA) The lowest limit value: Not applicable The highest limit value: Output value x 7.23 (mA) | ||
DTC P0135: Test ID $11: Component ID $06
PHO2S Heater (Bank 2)
| Test ID | $12 | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P0155 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 7.86 (mA) The lowest limit value: Output value (Decimal) x 7.86 (mA) The highest limit value: Not applicable | ||
DTC P0155: Test ID $12: Component ID $81
| Test ID | $13 | Test Limit Type and Component ID | $01 |
|---|---|---|---|
| DTC | P0155 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 7.86 (mA) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 7.86 (mA) | ||
DTC P0155: Test ID $13: Component ID $01
| Test ID | $12 | Test Limit Type and Component ID | $85 |
|---|---|---|---|
| DTC | P0155 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 26.7 (mA) The lowest limit value: Output value x 26.7 (mA) The highest limit value: Not applicable | ||
DTC P0155: Test ID $12: Component ID $85
| Test ID | $13 | Test Limit Type and Component ID | $05 |
|---|---|---|---|
| DTC | P0155 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 26.7 (mA) The lowest limit value: Not applicable The highest limit value: Output value x 26.7 (mA) | ||
DTC P0155: Test ID $13: Component ID $05
A/F Ratio Sensor
| Test ID | $0E | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P1167 | ||
| Test Description | Check of A/F sensor "non-activation" by monitoring the sensor non-activation time. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 1.0 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1.0 (sec.) | ||
DTC P1167: Test ID $0E: Component ID $00
SHO2S Heater (Bank 1)
| Test ID | $18 | Test Limit Type and Component ID | $86 |
|---|---|---|---|
| DTC | P0141 | ||
| Test Description | Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 7.23 (mA) The lowest limit value: Output value x 7.23 (mA) The highest limit value: Not applicable | ||
DTC P0141: Test ID $18: Component ID $86
| Test ID | $19 | Test Limit Type and Component ID | $06 |
|---|---|---|---|
| DTC | P0141 | ||
| Test Description | Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 7.23 (mA) The lowest limit value: Not applicable The highest limit value: Output value x 7.23 (mA) | ||
DTC P0141: Test ID $19: Component ID $06
SHO2S Heater (Bank 2)
| Test ID | $1A | Test Limit Type and Component ID | $86 |
|---|---|---|---|
| DTC | P0161 | ||
| Test Description | Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 7.23 (mA) The lowest limit value: Output value x 7.23 (mA) The highest limit value: Not applicable | ||
DTC P0161: Test ID $1A: Component ID $86
| Test ID | $1B | Test Limit Type and Component ID | $06 |
|---|---|---|---|
| DTC | P0161 | ||
| Test Description | Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 7.23 (mA) The lowest limit value: Not applicable The highest limit value: Output value x 7.23 (mA) | ||
DTC P0161: Test ID $1B: Component ID $06
EVAP System for tank leak check
| Test ID | $21 | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P1456 | ||
| Test Description | Monitoring the fluctuation of fuel tank pressure sensor output before and after the two-way bypass valve is opened after engine starting with cold condition. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.488281 (mmHg) The lowest limit value: Output value (Decimal) x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1456: Test ID $21: Component ID $81
| Test ID | $26 | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P1456 | ||
| Test Description | Monitoring either the difference between maximum and minimum of fuel tank pressure sensor output value in certain time after engine starting with cold condition or the difference between the sensor output value when valve is opened to air and that of monitoring. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.488281 (mmHg) The lowest limit value: Output value (Decimal) x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1456: Test ID $21: Component ID $81
| Test ID | $27 | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P1456 | ||
| Test Description | Monitoring the fluctuation of fuel tank pressure sensor output value. It should be monitored before and after the two-way bypass valve is opened, after fuel tank pressure is checked in certain time after engine starting with cold condition. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.488281 (mmHg) The lowest limit value: Output value (Decimal) x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1456: Test ID $27: Component ID $81
| Test ID | $21 | Test Limit Type and Component ID | $82 |
|---|---|---|---|
| DTC | P1456 | ||
| Test Description | Monitoring the fluctuation of fuel tank pressure sensor output before and after EVAP bypass solenoid valve is opened after engine starting with cold condition. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 (mmHg) The lowest limit value: Output value x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1456: Test ID $21: Component ID $82
| Test ID | $26 | Test Limit Type and Component ID | $82 |
|---|---|---|---|
| DTC | P1456 | ||
| Test Description | Monitoring either of: The difference between maximum and minimum of fuel tank pressure sensor output in predetermined time after engine starting with cold condition, or the difference between the sensor output when EVAP control canister vent shut and EVAP bypass solenoid valves are opened before performing tank leak check, and the sensor output during tank leak check. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 (mmHg) The lowest limit value: Output value x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1456: Test ID $26: Component ID $82
| Test ID | $27 | Test Limit Type and Component ID | $82 |
|---|---|---|---|
| DTC | P1456 | ||
| Test Description | Monitoring the fluctuation of fuel tank pressure sensor output before and after the EVAP bypass solenoid valve is opened, after fuel tank pressure check is completed in predetermined time after engine starting with cold condition | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 (mmHg) The lowest limit value: Output value x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1456: Test ID $27: Component ID $82
| Test ID | $38 | Test Limit Type and Component ID | $02 |
|---|---|---|---|
| DTC | P1456 | ||
| Test Description | Monitoring the difference of fuel tank pressure sensor output in pressure retention mode after decompressing the fuel tank. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value x 0.488281 (mmHg) | ||
DTC P1456: Test ID $38: Component ID $02
| Test ID | $3A | Test Limit Type and Component ID | $82 |
|---|---|---|---|
| DTC | P1456 | ||
| Test Description | Monitoring the fluctuation of fuel tank pressure sensor before and after the EVAP bypass solenoid valve is opened after engine starting with cold condition. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 (mmHg) The lowest limit value: Output value x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1456: Test ID $3A: Component ID $82
| Test ID | $3B | Test Limit Type and Component ID | $82 |
|---|---|---|---|
| DTC | P1456 | ||
| Test Description | Monitoring the difference between the sensor output when EVAP control canister vent shut and EVAP bypass solenoid valves are opened before performing tank leak check, and the sensor output during tank leak check. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 (mmHg) The lowest limit value: Output value x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1456: Test ID $3B: Component ID $82
| Test ID | $3C | Test Limit Type and Component ID | $02 |
|---|---|---|---|
| DTC | P1456 | ||
| Test Description | Monitoring the valve calculated by dividing the difference of fuel tank pressure sensor output in pressure retention mode after decompressing the fuel tank by EVAP leak monitoring time. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: No unit The lowest limit value: Not applicable The highest limit value: No unit | ||
DTC P1456: Test ID $3C: Component ID $02
EVAP System for canister leak check
| Test ID | $29 | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P1457 | ||
| Test Description | Monitoring the fuel tank pressure sensor output value when vent shut valve is closed while fuel tank pressure is equalized to same as atmospheric pressure before canister leak monitoring. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 - 62.500000 (mmHg) The lowest limit value: Output value x 0.488281 - 62.500000 (mmHg) The highest limit value: Not applicable | ||
DTC P1457: Test ID $29: Component ID $81
| Test ID | $2D | Test Limit Type and Component ID | $01 |
|---|---|---|---|
| DTC | P1457 | ||
| Test Description | Monitoring the fuel tank pressure sensor during decompressing pressure in EVAP vapor line | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 - 62.500000 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value x 0.488281 - 62.500000 (mmHg) | ||
DTC P1457: Test ID $2D: Component ID $01
| Test ID | $2E | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P1457 | ||
| Test Description | Monitoring the fluctuation of fuel tank pressure sensor output value before and after two-way bypass valve is opened. In this time canister side whose pressure is decreased and fuel tank whose pressure is not decreased are connected with. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 (mmHg) The lowest limit value: Output value x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1457: Test ID $2E: Component ID $81
| Test ID | $2F | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P1457 | ||
| Test Description | Monitoring the fuel tank pressure sensor output value when evaporative purge control solenoid valve is closed, two-way bypass valve and vent shut valve are opened before canister part decreasing. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 - 62.500000 (mmHg) The lowest limit value: Output value x 0.488281 - 62.500000 (mmHg) The highest limit value: Not applicable | ||
DTC P1457: Test ID $2F: Component ID $81
| Test ID | $29 | Test Limit Type and Component ID | $82 |
|---|---|---|---|
| DTC | P1457 | ||
| Test Description | Monitoring the fuel tank pressure sensor output when EVAP control canister vent shut valve is closed after releasing the pressure in EVAP vapor line. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.488281 - 62.500000 (mmHg) The lowest limit value: Output value (Decimal) x 0.488281 - 62.500000 (mmHg) The highest limit value: Not applicable | ||
DTC P1457: Test ID $29: Component ID $82
| Test ID | $2D | Test Limit Type and Component ID | $02 |
|---|---|---|---|
| DTC | P1457 | ||
| Test Description | Monitoring the fuel tank pressure sensor during decompressing pressure in EVAP vapor line. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 - 62.500000 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value x 0.488281 - 62.500000 (mmHg) | ||
DTC P1457: Test ID $2D: Component ID $02
| Test ID | $2E | Test Limit Type and Component ID | 82$ |
|---|---|---|---|
| DTC | P1457 | ||
| Test Description | Monitoring the fluctuation of fuel tank pressure sensor output after opening EVAP bypass solenoid valve while maintaining decompressed pressure in EVAP vapor line. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.488281 (mmHg) The lowest limit value: Output value (Decimal) x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1457: Test ID $2E: Component ID $82
| Test ID | $2F | Test Limit Type and Component ID | $82 |
|---|---|---|---|
| DTC | P1457 | ||
| Test Description | Monitoring the fuel tank pressure sensor output when EVAP canister purge valve is closed. and EVAP bypass solenoid and EVAP canister vent shut valves are opened before decompressing pressure in EVAP vapor line. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 - 62.500000 (mmHg) The lowest limit value: Output value x 0.488281 - 62.500000 (mmHg) The highest limit value: Not applicable | ||
DTC P1457: Test ID $2F: Component ID $82
| Test ID | $3E | Test Limit Type and Component ID | $82 |
|---|---|---|---|
| DTC | P1457 | ||
| Test Description | Monitoring the fluctuation of fuel tank pressure sensor output after opening EVAP bypass solenoid valve while maintaining decompressing pressure in EVAP vapor line. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.488281 (mmHg) The lowest limit value: Output value x 0.488281 (mmHg) The highest limit value: Not applicable | ||
DTC P1457: Test ID $3E: Component ID $82
Thermostat
| Test ID | $4D | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0128, P1486 | ||
| Test Description | Check of thermostat by monitoring the time interval until ECT sensor signal reaches target value. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value - 48 (°C) The lowest limit value: Output value - 48 (°C) The highest limit value: Not applicable | ||
DTC P0128, P1486: Test ID $4D: Component ID $80
| Test ID | $4E | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0128, P1486 | ||
| Test Description | Check of thermostat by monitoring the difference between actual ECT and predicted ECT. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value - 48 (°C) The lowest limit value: Output value - 48 (°C) The highest limit value: Not applicable | ||
DTC P0128, P1486: Test ID $4E: Component ID $80
| Test ID | $4F | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0128, P1486 | ||
| Test Description | Check of thermostat by monitoring the time interval until ECT sensor signal reaches target value. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value - 48 (°C) The lowest limit value: Output value - 48 (°C) The highest limit value: Not applicable | ||
DTC P0128, P1486: Test ID $4F: Component ID $80
| Test ID | $50 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0128, P1486 | ||
| Test Description | Check of thermostat by monitoring the difference between actual ECT and predicted ECT. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 1 (°C) The lowest limit value: Not applicable The highest limit value: Output value x 1 (°C) | ||
DTC P0128, P1486: Test ID $50: Component ID $00
| Test ID | $5C | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0128, P1486 | ||
| Test Description | Check of thermostat by monitoring the difference between actual ECT and predicted ECT. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.0195 (V) The lowest limit value: Not applicable The highest limit value: Output value x 0.0195 (V) | ||
DTC P0128, P1486: Test ID $5C: Component ID $00
| Test ID | $5D | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0128, P1486 | ||
| Test Description | Check of thermostat by monitoring the difference between actual ECT and predicted ECT. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.0195 (V) The lowest limit value: Not applicable The highest limit value: Output value x 0.0195 (V) | ||
DTC P0128, P1486: Test ID $5D: Component ID $00
| Test ID | $5E | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0128, P1486 | ||
| Test Description | Check of thermostat by monitoring the difference between actual ECT and predicted ECT. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.0195 (V) The lowest limit value: Not applicable The highest limit value: Output value x 0.0195 (V) | ||
DTC P0128, P1486: Test ID $5E: Component ID $00
| Test ID | $5F | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0128, P1486 | ||
| Test Description | Check of thermostat by monitoring the difference between actual ECT and predicted ECT. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 1 (°C) The lowest limit value: Not applicable The highest limit value: Output value x 1 (°C) | ||
DTC P0128, P1486: Test ID $5F: Component ID $00
Secondary Air System
| Test ID | $58 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0410 | ||
| Test Description | Check of secondary air system by monitoring the air pump electric current sensor output while the air pump is operated. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.2930 (A) The lowest limit value: Output value x 0.2930 (A) The highest limit value: Not applicable | ||
DTC P0410: Test ID $58: Component ID $80
| Test ID | $59 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P1410 | ||
| Test Description | Check of secondary air system by monitoring the air pump electric current sensor output while the air pump is operated. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.2930 (A) The lowest limit value: Not applicable The highest limit value: Output value x 0.2930 (A) | ||
DTC P1410: Test ID $59: Component ID $00
| Test ID | $5A | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0411 | ||
| Test Description | Check of secondary air system by monitoring the air pump electric current sensor output after the secondary air valve is opened. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.2930 (A) The lowest limit value: Output value x 0.2930 (A) The highest limit value: Not applicable | ||
DTC P0411: Test ID $5A: Component ID $80