INTRODUCTION
Mode 6 is designed to allow access to the results of onboard diagnostic monitoring tests of specific components/systems that are not continuously monitored. These systems include the catalytic converter, EVAP system, oxygen sensor, oxygen sensor heater, EGR system, secondary AIR system, and sometimes misfire.
Mode 6 data is output from the PCM/ECM in hexadecimal form. The $ sign indicates a hexadecimal number. Depending on the software in the scanner, the output could be displayed in hexadecimal numbers (no conversion), raw data (conversion to decimal numbers), or measurable values (applying conversion factor to raw data).
Before reading mode 6 information, ensure that the monitor for the information you are accessing has run to completion. If the monitor is not complete, the mode 6 data will not be accurate.
MODE $06 TEST IDENTIFICATION BY MODEL
| Monitor | Test ID | Test Limit Type and Comp. ID | RSX | TSX | TL | RL | MDX |
|---|---|---|---|---|---|---|---|
| EGR Flow | $01 | $80 | |||||
| $03 | $81 | X | X | X | |||
| $49 | $00 | X | X | X | |||
| $4A/$4B | $80/$00 | X | |||||
| $4A | $80 | X | X | ||||
| Catalyst (Bank 1) | $04 | $02 | |||||
| $05/$06 | $81/$81 | ||||||
| $62 | $04 | X | X | X | X | X | |
| Catalyst (Bank 2) | $07/$0A | $81/$81 | |||||
| $64 | $04 | X | X | X | |||
| A/F Sensor (Bank 1) | $76 | $80 | X | X | X | ||
| $78 | $80 | X | X | ||||
| $79 | $01 | X | X | X | |||
| A/F Sensor (Bank 2) | $77 | $80 | X | ||||
| $7A | $01 | X | X | X | |||
| A/F Sensor Heater (Bank 1) | $70/$71/$72 | $80/$00/$00 | X | ||||
| PHO2S Heater (Bank 1) | $10/$11 | $85/$05 | |||||
| $10/$11 | $88/$08 | ||||||
| SHO2S Heater (Bank 1) | $18/$19 | $85/$05 | |||||
| $18/$19 | $86/$06 | ||||||
| $18/$19 | $89/$09 | X | |||||
| PHO2S Heater (Bank 2) | $12/$13 | $85/$05 | |||||
| $12/$13 | $88/$08 | ||||||
| SHO2S Heater (Bank 2) | $1A/$1B | $86/$06 | |||||
| $1A/$1B | $89/$09 | ||||||
| PCV | $48 | $00 | |||||
| $48 | $01 | X | |||||
| Thermostat | $4D/$4E/$4F/$50 | $80/$80/$80/$00 | |||||
| $4D/$4E/$4F/$50 | $81/$81/$81/$01 | X | |||||
| $5C/$5D/$5E/$5F | $00/$00/$00/$00 | ||||||
| Secondary Air System | $58/$59/$5A | $80/$00/$80 | |||||
| EVAP System | $21/$26/$27/$38 | $83/$83/$83/$03 | |||||
| $29/$2E/$2F | $83/$83/$83 | ||||||
| $2D | $03 | ||||||
| $3A/$3B/$3C | $83/$83/$83 | ||||||
| $3E | $83 | ||||||
| $81 | $80 | X | X | X | X | X | |
| $82/$8F | $80/$80 | X | X | X | X | ||
| $83 | $00 | ||||||
| $85 | $00 | ||||||
| $86 | $00 | ||||||
| $87 | $00 | ||||||
| $88 | $00 | X | X | ||||
| $8B/$8D | $00/$00 | X | X | ||||
| $90/$91/$92/$93 | $00/$80/$80/$00 | X | X | ||||
| $94/$95/$96/$97 | $00/$80/$00/$00 | X | X | ||||
| $98 | $00 | ||||||
| $9A/$9B/$9C/$9D/$9E | $00/$00/$00/$00/$00 | X | X | X | |||
| $B0 | $00 | X | X | X | |||
| $B1 | $00 | ||||||
| $B2 | $00 | X | X | X | |||
| $B3 | $00 | ||||||
| $B4 | $00 | ||||||
| $B5 | $00 | X | X | X | |||
| $B6 | $00 | ||||||
| $B7 | $00 |
Mode $06 Test ID by Model
EGR Flow
| Test ID | $03 | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P0401 | ||
| Test Description | Check EGR flow by monitoring the change in intake manifold pressure between EGR valve open and closed during fuel cut. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (%) The lowest limit value: Output value (Decimal) x 0.1 (%) The highest limit value: Not applicable | ||
DTC P0401: Test ID $03: Component ID $81
| Test ID | $49 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0404 | ||
| Test Description | EGR valve check by comparing the difference between the actual valve lift and commanded valve lift. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (mm) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.01 (mm) | ||
DTC P0404: Test ID $49: Component ID $00
| Test ID | $4A | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P2413 | ||
| Test Description | EGR valve check by comparing the difference between the actual valve lift and commanded valve lift. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (mm) The lowest limit value: Output value (Decimal) x 0.01 (mm) The highest limit value: Not applicable | ||
DTC P2413: Test ID $4A: Component ID $80
| Test ID | $4B | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P2413 | ||
| Test Description | Check of EGR valve by comparing the actual valve lift value to the ECU commanded valve lift value. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value lift: Output value (Decimal) x 0.01 (mm) The lowest limit value lift: Not applicable The highest limit value lift: Output value (Decimal) x 0.01 (mm) | ||
DTC P2413: Test ID $4B: Component ID $00
Catalyst (Bank 1)
| Test ID | $62 | Test Limit Type and Component ID | $04 |
|---|---|---|---|
| DTC | P0420 | ||
| Test Description | Catalyst capability, monitored by measuring the fluctuation of the secondary oxygen sensor. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: No unit The lowest limit value: Not applicable The highest limit value: No unit | ||
DTC P0420: Test ID $62: Component ID $04
Catalyst (Bank 2)
| Test ID | $64 | Test Limit Type and Component ID | $04 |
|---|---|---|---|
| DTC | P0430 | ||
| Test Description | Catalyst capability, monitored by measuring the fluctuation of the secondary oxygen sensor. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: No unit The lowest limit value: Not applicable The highest limit value: No unit | ||
DTC P0430: Test ID $64: Component ID $04
A/F Sensor (Bank 1)
| Test ID | $76 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0133 | ||
| Test Description | A/F sensor response check by monitoring the amplitude of the filtered sensor signal during a stable driving condition. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: No unit The lowest limit value: No unit The highest limit value: Not applicable | ||
DTC P0133: Test ID $76: Component ID $80
| Test ID | $78 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P1172 | ||
| Test Description | A/F Sensor out of range check based on sensor output. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.00390625 - 128 (mA) The lowest limit value: Output value (Decimal) x 0.00390625 - 128 (mA) The highest limit value: Not applicable | ||
DTC P1172: Test ID $78: Component ID $80
| Test ID | $79 | Test Limit Type and Component ID | $01 |
|---|---|---|---|
| DTC | P1172 | ||
| Test Description | A/F Sensor out of range check based on sensor output. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.00390625 (mA) - 128 (mA) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.00390625 (mA) - 128 (mA) | ||
DTC P1172: Test ID $79: Component ID $01
A/F Sensor (Bank 2)
| Test ID | $77 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0153 | ||
| Test Description | A/F sensor response check by monitoring the amplitude of the filtered sensor signal during a stable driving condition. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: No unit The lowest limit value: No unit The highest limit value: Not applicable | ||
DTC P0153: Test ID $77: Component ID $80
| Test ID | $7A | Test Limit Type and Component ID | $01 |
|---|---|---|---|
| DTC | P1174 | ||
| Test Description | A/F Sensor out of range check based on sensor output. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.00390625 (mA) - 128 (mA) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.00390625 (mA) - 128 (mA) | ||
DTC P1174: Test ID $7A: Component ID $01
A/F Sensor Heater (Bank 1)
| Test ID | $70 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0135 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (A) The lowest limit value: Output value (Decimal) x 0.01 (A) The highest limit value: Not applicable | ||
DTC P0135: Test ID $70: Component ID $80
| Test ID | $71 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0135 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (A) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.01 (A) | ||
DTC P0135: Test ID $71: Component ID $00
| Test ID | $72 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0135 | ||
| Test Description | Circuit check of A/F sensor heater by monitoring the sensor output current during heater off. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (A) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.01 (A) | ||
DTC P0135: Test ID $72: Component ID $00
SHO2S Heater (Bank 1)
| Test ID | $18 | Test Limit Type and Component ID | $89 |
|---|---|---|---|
| DTC | P0141 | ||
| Test Description | Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (A) The lowest limit value: Output value (Decimal) x 0.01 (A) The highest limit value: Not applicable | ||
DTC P0141: Test ID $18: Component ID $89
| Test ID | $19 | Test Limit Type and Component ID | $09 |
|---|---|---|---|
| DTC | P0141 | ||
| Test Description | Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (A) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.01 (A) | ||
DTC P0141: Test ID $19: Component ID $09
PCV
| Test ID | $48 | Test Limit Type and Component ID | $01 |
|---|---|---|---|
| DTC | P2279 | ||
| Test Description | Check of PCV system by comparing the estimated intake air volume with the actual intake air volume during idle condition. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value x 0.10 (l/min.) The lowest limit value: Not applicable The highest limit value: Output value x 0.10 (l/min.) | ||
DTC P2279: Test ID $48: Component ID $01
Thermostat
| Test ID | $4D | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P0128 | ||
| Test Description | Check of thermostat by monitoring the time interval until ECT sensor signal reaches target value. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) - 40 (°C) The lowest limit value: Output value (Decimal) - 40 (°C) The highest limit value: Not applicable | ||
DTC P0128: Test ID $4D: Component ID $81
| Test ID | $4E | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P0128 | ||
| Test Description | Check of thermostat by monitoring the difference between actual ECT and predicted ECT. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) - 40 (°C) The lowest limit value: Output value (Decimal) - 40 (°C) The highest limit value: Not applicable | ||
DTC P0128: Test ID $4E: Component ID $81
| Test ID | $4F | Test Limit Type and Component ID | $81 |
|---|---|---|---|
| DTC | P0128 | ||
| Test Description | Check of thermostat by monitoring the difference between actual ECT and predicted ECT. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) - 40 (°C) The lowest limit value: Output value (Decimal) - 40 (°C) The highest limit value: Not applicable | ||
DTC P0128: Test ID $4F: Component ID $81
| Test ID | $50 | Test Limit Type and Component ID | $01 |
|---|---|---|---|
| DTC | P0128 | ||
| Test Description | Check of thermostat by monitoring the difference between actual ECT and predicted ECT. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 1 (°C) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1 (°C) | ||
DTC P0128: Test ID $50: Component ID $01
EVAP System
| Test ID | $81 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0496 | ||
| Test Description | EVAP canister purge valve "stuck open" check by monitoring fuel tank pressure sensor while the engine is running. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The highest limit value: Not applicable | ||
DTC P0496: Test ID $81: Component ID $80
| Test ID | $82 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P2422 | ||
| Test Description | EVAP canister purge valve "stuck close" check by monitoring fuel tank pressure sensor while the engine is running. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The highest limit value: Not applicable | ||
DTC P2422: Test ID $82: Component ID $80
| Test ID | $8F | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P2422 | ||
| Test Description | EVAP canister purge valve "stuck close" check by monitoring fuel tank pressure sensor at engine start. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The highest limit value: Not applicable | ||
DTC P2422: Test ID $8F: Component ID $80
| Test ID | $88 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0497 | ||
| Test Description | Purge flow check by monitoring fuel tank pressure sensor value while the engine is running. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) | ||
DTC P0497: Test ID $88: Component ID $00
| Test ID | $8B | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0457 | ||
| Test Description | Loose fuel cap check or gross leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompressing. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) | ||
DTC P0457: Test ID $8B: Component ID $00
| Test ID | $8D | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0457 | ||
| Test Description | Gross leak check of EVAP system by monitoring the fuel tank pressure sensor value after decompress mode. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) | ||
DTC P0457: Test ID $8D: Component ID $00
| Test ID | $90 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0442 | ||
| Test Description | Leak check of EVAP system by monitoring the fuel tank pressure sensor value before purge started. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) | ||
DTC P0442: Test ID $90: Component ID $00
| Test ID | $91 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0442 | ||
| Test Description | Leak check of EVAP system by monitoring the fuel tank pressure sensor value while the engine is running. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The highest limit value: Not applicable | ||
DTC P0442: Test ID $91: Component ID $80
| Test ID | $92 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0442 | ||
| Test Description | Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the decompression mode. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The highest limit value: Not applicable | ||
DTC P0442: Test ID $92: Component ID $80
| Test ID | $93 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0442 | ||
| Test Description | Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the decompression mode. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg/min.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg/min.) | ||
DTC P0442: Test ID $93: Component ID $00
| Test ID | $94 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0456 | ||
| Test Description | Leak check of EVAP system by monitoring the fuel tank pressure sensor value while the engine is running. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) | ||
DTC P0456: Test ID $94: Component ID $00
| Test ID | $95 | Test Limit Type and Component ID | $80 |
|---|---|---|---|
| DTC | P0456 | ||
| Test Description | Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the decompression mode. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The highest limit value: Not applicable | ||
DTC P0456: Test ID $95: Component ID $80
| Test ID | $96 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0456 | ||
| Test Description | Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the decompression mode. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg/min.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg/min.) | ||
DTC P0456: Test ID $96: Component ID $00
| Test ID | $97 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0456 | ||
| Test Description | Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the decompression mode. | ||
| Store Timing | Normal judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg/min.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg/min.) | ||
DTC P0456: Test ID $97: Component ID $00
| Test ID | $9A | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0456 | ||
| Test Description | Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the soak period after the engine is turned off. (EONV) | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) / 1024 - 32 The lowest limit value: Not applicable The highest limit value: Output value (Decimal) / 1024 - 32 | ||
DTC P0456: Test ID $9A: Component ID $00
| Test ID | $9B | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0456 | ||
| Test Description | Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the soak period after the engine is turned off. (EONV) | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) / 32 - 1024 The lowest limit value: Not applicable The highest limit value: Output value (Decimal) / 32 - 1024 | ||
DTC P0456: Test ID $9B: Component ID $00
| Test ID | $9C | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0456 | ||
| Test Description | Leak check of EVAP system by monitoring time it takes the fuel tank pressure sensor to equal atmosphere pressure after the engine off. (EONV) | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 1.0 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1.0 (sec.) | ||
DTC P0456: Test ID $9C: Component ID $00
| Test ID | $9D | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0456 | ||
| Test Description | Check of fuel tank pressure sensor signal unstable after the engine off. (early EONV) | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.001 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.001 (mmHg) | ||
DTC P0456: Test ID $9D: Component ID $00
| Test ID | $9E | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0456 | ||
| Test Description | Loose fuel cap check or gross leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompressing. | ||
| Store Timing | Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.08 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.08 (sec.) | ||
DTC P0456: Test ID $9E: Component ID $00
| Test ID | $B0 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0497 | ||
| Test Description | Purge flow check by monitoring fuel tank pressure sensor value when the EVAP canister purge valve is closed. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) | ||
DTC P0497: Test ID $B0: Component ID $00
| Test ID | $B2 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0457 | ||
| Test Description | Loose fuel cap check or gross leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompressing. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) | ||
DTC P0457: Test ID $B2: Component ID $00
| Test ID | $B5 | Test Limit Type and Component ID | $00 |
|---|---|---|---|
| DTC | P0455 | ||
| Test Description | Gross leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompressing. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) | ||
DTC P0455: Test ID $B5: Component ID $00