Contents Wiring diagrams Section: Mode 6 All sections

Mode 6 - 2007 Acura Acura RDX I

Mode 6 ~791 words

INTRODUCTION

Mode 6 is designed to allow access to the results of onboard diagnostic monitoring tests of specific components/systems that are not continuously monitored. These systems include the catalytic converter, EVAP system, oxygen sensor, oxygen sensor heater, EGR system, secondary AIR system, and sometimes misfire.

Mode 6 data is output from the PCM/ECM in hexadecimal form. The $ sign indicates a hexadecimal number. Depending on the software in the scanner, the output could be displayed in hexadecimal numbers (no conversion), raw data (conversion to decimal numbers), or measurable values (applying conversion factor to raw data).

Before reading mode 6 information, ensure that the monitor for the information you are accessing has run to completion. If the monitor is not complete, the mode 6 data will not be accurate.

MODE $06 TEST IDENTIFICATION BY MODEL

MonitorTest IDTest Limit Type and Comp. IDRL
EGR Flow$01$80
$03$81X
$49$00X
$4A/$4B$80/$00
$4A$80X
Catalyst (Bank 1)$04$02
$05/$06$81/$81
$62$04X
Catalyst (Bank 2)$07/$0A$81/$81
$64$04X
AF Sensor (Bank 1)$76$80X
$78$80
$79$01X
AF Sensor (Bank 2)$77$80X
$7A$01X
A/F Sensor Heater (Bank 1)$70/$71/$72$80/$00/$00
PHO2S Heater (Bank 1)$10/$11$85/$05
$10/$11$88/$08
SHO2S Heater (Bank 1)$18/$19$85/$05
$18/$19$86/$06
$18/$19$89/$09
PHO2S Heater (Bank 2)$12/$13$85/$05
$12/$13$88/$08
SHO2S Heater (Bank 2)$1A/$1B$86/$06
$1A/$1B$89/$09
PCV$48$00
$48$01
Thermostat$4D/$4E/$4F/$50$80/$80/$80/$00
$4D/$4E/$4F/$50$81/$81/$81/$01
$5C/$5D/$5E/$5F$00/$00/$00/$00
Secondary Air System$58/$59/$5A$80/$00/$80
EVAP System$21/$26/$27/$38$83/$83/$83/$03
$29/$2E/$2F$83/$83/$83
$2D$03
$3A/$3B/$3C$83/$83/$03
$3E$83
$81$80X
$82/$8F$80/$80X
$83$00
$85$00
$86$00
$87$00
$88$00
$8B/$8D$00/$00
$90/$91/$92/$93$00/$80/$80/$00
$94/$95/$96/$97$00/$80/$00/$00
$98$00
$9A/$9B/$9C/$9D/$9E$00/$00/$00/$00/$00X
$B0$00X
$B1$00
$B2$00X
$B3$00
$B4$00
$B5$00X
$B6$00
$B7$00

Mode $06 Test ID by Model - Group 1

MonitorOBD Monitor IDTest IDUnit and Scaling IDRDXTLMDXTSX
AF Sensor (Bank 1)$01$80$11XXXX
$01$81$14XXXX
$01$82$0BXX
$01$83$8DXXXX
$01$84$8DXXXX
$01$85$01XXXX
$01$86$8DXXXX
$01$87$14XXXX
$01$88$0BXX
AF Sensor (Bank 2)$05$80$11XX
$05$81$14XX
$05$82$0BXX
$05$83$8DXX
$05$84$8DXX
$05$85$01XX
$05$86$8DXX
$05$87$14XX
$05$88$0BXX
Secondary HO2S (Bank 1)$02$98$0BXXXX
$02$99$0BXXXX
$02$9A$0BXXXX
$02$9B$10XXXX
$02$9C$0BXXXX
Secondary HO2S (Bank 2)$06$98$0BXX
$06$99$0BXX
$06$9A$0BXX
$06$9B$10XX
$06$9C$0BXX
Catalyst (Bank 1)$21$A0$01XXXX
$21$A1$0B
Catalyst (Bank 2)$22$A0$01XX
EGR System$31$D0$32XX
$31$D1$32XX
$31$D2$39XX
$31$D3$01
EVAP System$39$B2$FDX
$3A$B3$FDX
$3A$BA$12XXX
$3C$B4$06XXXX
$3C$B5$83XXXX
$3C$B6$12XXXX
$3C$B7$10XXXX
$3C$B8$FEXXXX
$3D$B0$FDX
$3D$B1$FDX
$3D$B9$30XXX
$3D$BB$30X
$3D$BC$10X
Fuel System (Bank 1)$81$D8$05XXXX
Fuel System (Bank 2)$82$D8$05XX
Misfire$A2$0C$24XXXX
$A3$0C$24XXXX
$A4$0C$24XXXX
$A5$0C$24XXXX
$A6$0C$24XX
$A7$0C$24XX

Mode $06 Test ID by Model - Group 2

EGR Flow

Test ID$03Test Limit Type and Component ID$81
DTCP0401
Test DescriptionCheck EGR flow by monitoring the change in intake manifold pressure between EGR valve open and closed during fuel cut.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.1 (%) The lowest limit value: Output value (Decimal) x 0.1 (%) The highest limit value: Not applicable

DTC P0401: Test ID $03: Component ID $81

Test ID$49Test Limit Type and Component ID$00
DTCP0404
Test DescriptionEGR valve check by comparing the difference between the actual valve lift and commanded valve lift.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.01 (mm) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.01 (mm)

DTC P0404: Test ID $49: Component ID $00

Test ID$4ATest Limit Type and Component ID$80
DTCP2413
Test DescriptionEGR valve check by comparing the difference between the actual valve lift and commanded valve lift.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.01 (mm) The lowest limit value: Output value (Decimal) x 0.01 (mm) The highest limit value: Not applicable

DTC P2413: Test ID $4A: Component ID $80

Catalyst (Bank 1)

Test ID$62Test Limit Type and Component ID$04
DTCP0420
Test DescriptionCatalyst capability, monitored by measuring the fluctuation of the secondary oxygen sensor.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: No unit The lowest limit value: Not applicable The highest limit value: No unit

DTC P0420: Test ID $62: Component ID $04

Catalyst (Bank 2)

Test ID$64Test Limit Type and Component ID$04
DTCP0430
Test DescriptionCatalyst capability, monitored by measuring the fluctuation of the secondary oxygen sensor.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: No unit The lowest limit value: Not applicable The highest limit value: No unit

DTC P0430: Test ID $64: Component ID $04

A/F Sensor (Bank 1)

Test ID$76Test Limit Type and Component ID$80
DTCP0133
Test DescriptionA/F sensor response check by monitoring the amplitude of the filtered sensor signal during a stable driving condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: No unit The lowest limit value: No unit The highest limit value: Not applicable

DTC P0133: Test ID $76: Component ID $80

Test ID$79Test Limit Type and Component ID$01
DTCP1172
Test DescriptionA/F Sensor out of range check based on sensor output.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.00390625 (mA) - 128 (mA) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.00390625 (mA) - 128 (mA)

DTC P1172: Test ID $79: Component ID $01

A/F Sensor (Bank 2)

Test ID$77Test Limit Type and Component ID$80
DTCP0153
Test DescriptionA/F sensor response check by monitoring the amplitude of the filtered sensor signal during a stable driving condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: No unit The lowest limit value: No unit The highest limit value: Not applicable

DTC P0153: Test ID $77: Component ID $80

Test ID$7ATest Limit Type and Component ID$01
DTCP1174
Test DescriptionA/F Sensor out of range check based on sensor output.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.00390625 (mA) - 128 (mA) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.00390625 (mA) - 128 (mA)

DTC P1174: Test ID $7A: Component ID $01

EVAP System

Test ID$81Test Limit Type and Component ID$80
DTCP0496
Test DescriptionEVAP canister purge valve "stuck open" check by monitoring fuel tank pressure sensor while the engine is running.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The highest limit value: Not applicable

DTC P0496: Test ID $81: Component ID $80

Test ID$82Test Limit Type and Component ID$80
DTCP2422
Test DescriptionEVAP canister purge valve "stuck close" check by monitoring fuel tank pressure sensor while the engine is running.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The highest limit value: Not applicable

DTC P2422: Test ID $82: Component ID $80

Test ID$8FTest Limit Type and Component ID$80
DTCP2422
Test DescriptionEVAP canister purge valve "stuck close" check by monitoring fuel tank pressure sensor at engine start.
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The highest limit value: Not applicable

DTC P2422: Test ID $8F: Component ID $80

Test ID$9ATest Limit Type and Component ID$00
DTCP0456
Test DescriptionLeak check of EVAP system by monitoring the fuel tank pressure sensor value during the soak period after the engine is turned off. (EONV)
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) / 1024 - 32 The lowest limit value: Not applicable The highest limit value: Output value (Decimal) / 1024 - 32

DTC P0456: Test ID $9A: Component ID $00

Test ID$9BTest Limit Type and Component ID$00
DTCP0456
Test DescriptionLeak check of EVAP system by monitoring the fuel tank pressure sensor value during the soak period after the engine is turned off. (EONV)
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) / 32 - 1024 The lowest limit value: Not applicable The highest limit value: Output value (Decimal) / 32 - 1024

DTC P0456: Test ID $9B: Component ID $00

Test ID$9CTest Limit Type and Component ID$00
DTCP0456
Test DescriptionLeak check of EVAP system by monitoring time it takes the fuel tank pressure sensor to equal atmosphere pressure after the engine off. (EONV)
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1.0 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1.0 (sec.)

DTC P0456: Test ID $9C: Component ID $00

Test ID$9DTest Limit Type and Component ID$00
DTCP0456
Test DescriptionCheck of fuel tank pressure sensor signal unstable after the engine off. (early EONV)
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.001 (mmHg)

DTC P0456: Test ID $9D: Component ID $00

Test ID$9ETest Limit Type and Component ID$00
DTCP0456
Test DescriptionLoose fuel cap check or gross leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompressing.
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.08 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.08 (sec.)

DTC P0456: Test ID $9E: Component ID $00

Test ID$B0Test Limit Type and Component ID$00
DTCP0497
Test DescriptionPurge flow check by monitoring fuel tank pressure sensor value when the EVAP canister purge valve is closed.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)

DTC P0497: Test ID $B0: Component ID $00

Test ID$B2Test Limit Type and Component ID$00
DTCP0457
Test DescriptionLoose fuel cap check or gross leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompressing.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)

DTC P0457: Test ID $B2: Component ID $00

Test ID$B5Test Limit Type and Component ID$00
DTCP0455
Test DescriptionGross leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompressing.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)

DTC P0455: Test ID $B5: Component ID $00

OBD Monitor ID$01Test ID$80Unit and Scaling ID$11
DTCP0134
Test DescriptionCheck of A/F sensor "non-activation" time. See Test ID $81 and $82 for "non-activation" criteria.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.1 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (sec.)

DTC P0134: Monitor ID $01: Test ID $80

OBD Monitor ID$01Test ID$81Unit and Scaling ID$14
DTCP0134
Test DescriptionCheck of A/F sensor "non-activation" by monitoring the sensor element resistance.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (ohms) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1 (ohms)

DTC P0134: Monitor ID $01: Test ID $81

OBD Monitor ID$01Test ID$82Unit and Scaling ID$0B
DTCP0134
Test DescriptionCheck of A/F sensor "non-activation" by monitoring the sensor cell voltage.
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.01 (V) The lowest limit value: Output value (Decimal) x 0.01 (V) The highest limit value: Output value (Decimal) x 0.01 (V)

DTC P0134: Monitor ID $01: Test ID $82

OBD Monitor ID$01Test ID$83Unit and Scaling ID$8D
DTCP2195
Test DescriptionCheck of the A/F sensor "too lean" by monitoring the A/F sensor signal.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.003906 (mA) The lowest limit value: Output value (Decimal) x 0.003906 (mA) The highest limit value: Not applicable

DTC P2195: Monitor ID $01: Test ID $83

OBD Monitor ID$01Test ID$84Unit and Scaling ID$8D
DTCP2A00
Test DescriptionCheck of A/F sensor rationality by monitoring the sensor signal during fuel cut condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.003906 (mA) The lowest limit value: Output value (Decimal) x 0.003906 (mA) The highest limit value: Output value (Decimal) x 0.003906 (mA)

DTC PA00: Monitor ID $01: Test ID $84

OBD Monitor ID$01Test ID$85Unit and Scaling ID$01
DTCP0133
Test DescriptionResponse check of A/F sensor by monitoring the amplitude of filtered sensor signal during stable driving condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: No unit The lowest limit value: No unit The highest limit value: Not applicable

DTC P0133: Monitor ID $01: Test ID $85

OBD Monitor ID$01Test ID$86Unit and Scaling ID$8D
DTCP1172
Test DescriptionCheck of A/F sensor "out of range" by monitoring the sensor signal.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.003906 (mA) The lowest limit value: Output value (Decimal) x 0.003906 (mA) The highest limit value: Not applicable

DTC P1172: Monitor ID $01: Test ID $86

OBD Monitor ID$01Test ID$87Unit and Scaling ID$14
DTCP0134
Test DescriptionCheck of A/F sensor "non-activation" by monitoring the sensor element resistance during A/F feedback control.
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (ohms) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1 (ohms)

DTC P0134: Monitor ID $01: Test ID $87

OBD Monitor ID$01Test ID$88Unit and Scaling ID$0B
DTCP0134
Test DescriptionCheck of A/F sensor "non-activation" by monitoring the sensor cell voltage during A/F feedback control.
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.01 (V) The lowest limit value: Output value (Decimal) x 0.01 (V) The highest limit value: Output value (Decimal) x 0.01 (V)

DTC P0134: Monitor ID $01: Test ID $88

OBD Monitor ID$05Test ID$80Unit and Scaling ID$11
DTCP0154
Test DescriptionCheck of A/F sensor "non-activation" by monitoring the sensor non-activation time.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.1 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (sec.)

DTC P0154: Monitor ID $05: Test ID $80

OBD Monitor ID$05Test ID$81Unit and Scaling ID$14
DTCP0154
Test DescriptionCheck of A/F sensor "non-activation" by monitoring the sensor element resistance.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (ohms) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1 (ohms)

DTC P0154: Monitor ID $05: Test ID $81

OBD Monitor ID$05Test ID$82Unit and Scaling ID$0B
DTCP0154
Test DescriptionCheck of A/F sensor "non-activation" by monitoring the sensor cell voltage.
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.01 (V) The lowest limit value: Output value (Decimal) x 0.01 (V) The highest limit value: Output value (Decimal) x 0.01 (V)

DTC P0154: Monitor ID $05: Test ID $82

OBD Monitor ID$05Test ID$83Unit and Scaling ID$8D
DTCP2197
Test DescriptionCheck of the A/F sensor "too lean" by monitoring the A/F sensor signal.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.003906 (mA) The lowest limit value: Output value (Decimal) x 0.003906 (mA) The highest limit value: Not applicable

DTC P2197: Monitor ID $05: Test ID $83

OBD Monitor ID$05Test ID$84Unit and Scaling ID$8D
DTCP2A03
Test DescriptionCheck of A/F sensor rationality by monitoring the sensor signal during fuel cut condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.003906 (mA) The lowest limit value: Output value (Decimal) x 0.003906 (mA) The highest limit value: Output value (Decimal) x 0.003906 (mA)

DTC P2A03: Monitor ID $05: Test ID $84

OBD Monitor ID$05Test ID$85Unit and Scaling ID$01
DTCP0153
Test DescriptionResponse check of A/F sensor by monitoring the amplitude of filtered sensor signal during stable driving condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: No unit The lowest limit value: No unit The highest limit value: Not applicable

DTC P0153: Monitor ID $05: Test ID $01

OBD Monitor ID$05Test ID$86Unit and Scaling ID$8D
DTCP1174
Test DescriptionCheck of A/F sensor "out of range" by monitoring the sensor signal.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.003906 (mA) The lowest limit value: Output value (Decimal) x 0.003906 (mA) The highest limit value: Not applicable

DTC P1174: Monitor ID $05: Test ID $86

OBD Monitor ID$05Test ID$87Unit and Scaling ID$14
DTCP0154
Test DescriptionCheck of A/F sensor "non-activation" by monitoring the sensor element resistance during A/F feedback control.
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (ohms) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1 (ohms)

DTC P0154: Monitor ID $05: Test ID $87

OBD Monitor ID$05Test ID$88Unit and Scaling ID$0B
DTCP0154
Test DescriptionCheck of A/F sensor "non-activation" by monitoring the sensor cell voltage during A/F feedback control.
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.01 (V) The lowest limit value: Output value (Decimal) x 0.01 (V) The highest limit value: Output value (Decimal) x 0.01 (V)

DTC P0154: Monitor ID $05: Test ID $88

Secondary HO2S (Bank 1)

OBD Monitor ID$02Test ID$98Unit and Scaling ID$0B
DTCP2270
Test DescriptionCheck of secondary oxygen sensor signal "lean" stuck by monitoring the sensor output voltage after fuel cut condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (V) The lowest limit value: Output value (Decimal) x 0.001 (V) The highest limit value: Not applicable

DTC P2270: Monitor ID $02: Test ID $98

OBD Monitor ID$02Test ID$99Unit and Scaling ID$0B
DTCP2271
Test DescriptionCheck of secondary oxygen sensor signal "rich" stuck by monitoring the sensor output voltage after fuel cut condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (V) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.001 (V)

DTC P2271: Monitor ID $02: Test ID $99

OBD Monitor ID$02Test ID$9AUnit and Scaling ID$0B
DTCP0137
Test DescriptionCircuit check of secondary oxygen sensor by monitoring the sensor output voltage.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (V) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.001 (V)

DTC P0137: Monitor ID $02: Test ID $9A

OBD Monitor ID$02Test ID$9BUnit and Scaling ID$10
DTCP0139
Test DescriptionResponse check of secondary oxygen sensor by monitoring the sensor output voltage after fuel cut condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1 (sec.)

DTC P0139: Monitor ID $02: Test ID $9B

OBD Monitor ID$02Test ID$9CUnit and Scaling ID$0B
DTCP0138
Test DescriptionCircuit check of secondary oxygen sensor by monitoring the sensor output voltage.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (V) The lowest limit value: Output value (Decimal) x 0.001 (V) The highest limit value: Not applicable

DTC P0138: Monitor ID $02: Test ID $9C

Secondary HO2S (Bank 2)

OBD Monitor ID$06Test ID$98Unit and Scaling ID$0B
DTCP2272
Test DescriptionCheck of secondary oxygen sensor signal "lean" stuck by monitoring the sensor output voltage after fuel cut condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (V) The lowest limit value: Output value (Decimal) x 0.001 (V) The highest limit value: Not applicable

DTC P2272: Monitor ID $06: Test ID $98

OBD Monitor ID$06Test ID$99Unit and Scaling ID$0B
DTCP2273
Test DescriptionCheck of secondary oxygen sensor signal "rich" stuck by monitoring the sensor output voltage after fuel cut condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (V) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.001 (V)

DTC P2273: Monitor ID $06: Test ID $99

OBD Monitor ID$06Test ID$9AUnit and Scaling ID$0B
DTCP0157
Test DescriptionCircuit check of secondary oxygen sensor by monitoring the sensor output voltage.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (V) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.001 (V)

DTC P0157: Monitor ID $06: Test ID $9A

OBD Monitor ID$06Test ID$9BUnit and Scaling ID$10
DTCP0159
Test DescriptionResponse check of secondary oxygen sensor by monitoring the sensor output voltage after fuel cut condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1 (sec.)

DTC P0159: Monitor ID $06: Test ID $9B

OBD Monitor ID$06Test ID$9CUnit and Scaling ID$0B
DTCP0158
Test DescriptionCircuit check of secondary oxygen sensor by monitoring the sensor output voltage.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (V) The lowest limit value: Output value (Decimal) x 0.001 (V) The highest limit value: Not applicable

DTC P0158: Monitor ID $06: Test ID $9C

OBD Monitor ID$21Test ID$A0Unit and Scaling ID$01
DTCP0420
Test DescriptionCatalyst capability, monitored by measuring the fluctuation of the secondary oxygen sensor output value.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: No unit The lowest limit value: Not applicable The highest limit value: No unit

DTC P0420: Monitor ID $21: Test ID $A0

OBD Monitor ID$22Test ID$A0Unit and Scaling ID$01
DTCP0430
Test DescriptionCheck of catalyst capability by monitoring the fluctuation of the secondary oxygen sensor output value.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: No unit The lowest limit value: Not applicable The highest limit value: No unit

DTC P0430: Monitor ID $22: Test ID $A0

EGR System

OBD Monitor ID$31Test ID$D0Unit and Scaling ID$32
DTCP0404
Test DescriptionCheck of EGR valve by comparing the actual valve lift value to the ECM/PCM commanded valve lift value.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.0000305 (inch) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.0000305 (inch)

DTC P0404: Monitor ID $31: Test ID $D0

OBD Monitor ID$31Test ID$D1Unit and Scaling ID$32
DTCP2413
Test DescriptionCheck of EGR valve by comparing the actual valve lift value to the ECM/PCM commanded valve lift value.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value lift: Output value (Decimal) x 0.0000305 (inch) The lowest limit value lift: Output value (Decimal) x 0.0000305 (inch) The highest limit value lift: Not applicable

DTC P2413: Monitor ID $31: Test ID $D1

OBD Monitor ID$31Test ID$D2Unit and Scaling ID$39
DTCP0401
Test DescriptionCheck EGR flow by monitoring the change in intake manifold pressure between EGR valve open and closed during fuel cut.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.01 (%) The lowest limit value: Output value (Decimal) x 0.01 (%) The highest limit value: Not applicable

DTC P0401: Monitor ID $31: Test ID $D2

OBD Monitor ID$39Test ID$B2Unit and Scaling ID$FD
DTCP0457
Test DescriptionLoose fuel cap check or gross leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompressing.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (kPa) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.001 (kPa)

DTC P0457: Monitor ID $39: Test ID $B2

OBD Monitor ID$3ATest ID$B3Unit and Scaling ID$FD
DTCP0455
Test DescriptionGross leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompressing.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (kPa) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.001 (kPa)

DTC P0455: Monitor ID $3A: Test ID $B3

OBD Monitor ID$3ATest ID$BAUnit and Scaling ID$12
DTCP0455
Test DescriptionGross leak check of EVAP system by monitoring time of the fuel tank pressure sensor value which is equal atmosphere after the engine off. (EONV)
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1.0 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1.0 (sec.)

DTC P0455: Monitor ID $3A: Test ID $BA

OBD Monitor ID$3CTest ID$B4Unit and Scaling ID$06
DTCP0456
Test DescriptionLeak check of EVAP system by monitoring the fuel tank pressure sensor value after the engine off. (EONV)
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.000305 The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.000305

DTC P0456: Monitor ID $3C: Test ID $B4

OBD Monitor ID$3CTest ID$B5Unit and Scaling ID$83
DTCP0456
Test DescriptionLeak check of EVAP system by monitoring the fuel tank pressure sensor value after the engine off. (EONV)
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.01 The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.01

DTC P0456: Monitor ID $3C: Test ID $B5

OBD Monitor ID$3CTest ID$B6Unit and Scaling ID$12
DTCP0456
Test DescriptionLeak check of EVAP system by monitoring time of the fuel tank pressure sensor value which is equal atmosphere after the engine off. (EONV)
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1.0 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1.0 (sec.)

DTC P0456: Monitor ID $3C: Test ID $B6

OBD Monitor ID$3CTest ID$B7Unit and Scaling ID$10
DTCP0456
Test DescriptionCheck of fuel tank pressure sensor signal unstable after the engine off. (early EONV)
Store TimingFailure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1.0 (msec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1.0 (msec.)

DTC P0456: Monitor ID $3C: Test ID $B7

OBD Monitor ID$3CTest ID$B8Unit and Scaling ID$FE
DTCP0456
Test DescriptionCheck of EVAP system by monitoring the fuel tank pressure sensor signal after the engine off. (comparison with atmosphere)
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.25 (Pa) The lowest limit value: Output value (Decimal) x 0.25 (Pa) The highest limit value: Output value (Decimal) x 0.25 (Pa)
NOTE: For the following vehicle: [RDX, TL, MDX, TSX] Incorrect output,. The lowest limit value: Not applicable. may be indicated. In spite of failure condition, some generic scan tool may be output as normal condition.
NOTE
For the following vehicle: [RDX, TL, MDX, TSX] Incorrect output,. The lowest limit value: Not applicable. may be indicated. In spite of failure condition, some generic scan tool may be output as normal condition.

DTC P0456: Monitor ID $3C: Test ID $B8

OBD Monitor ID$3DTest ID$B0Unit and Scaling ID$FD
DTCP0496
Test DescriptionEVAP canister purge valve "stuck open" check by monitoring fuel tank pressure sensor while the engine is running.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (kPa) The lowest limit value: Output value (Decimal) x 0.001 (kPa) The highest limit value: Not applicable

DTC P0496: Monitor ID $3D: Test ID $B0

OBD Monitor ID$3DTest ID$B1Unit and Scaling ID$FD
DTCP0497
Test DescriptionPurge flow check by monitoring fuel tank pressure sensor value when the EVAP canister purge valve is closed.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001 (kPa) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.001 (kPa)

DTC P0497: Monitor ID $3D: Test ID $B1

OBD Monitor ID$3DTest ID$B9Unit and Scaling ID$30
DTCP0457, P0496, P145C
Test DescriptionPurge flow and/or EVAP canister purge valve check by monitoring fuel tank pressure sensor value while the engine is running.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.001526 (%) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.001526 (%)

DTC P0457, P0496, P145C: Monitor ID $3D: Test ID $B9

OBD Monitor ID$3DTest ID$BBUnit and Scaling ID$30
DTCP145A, P145D
Test DescriptionPurge flow and/or EVAP canister purge valve check by monitoring fuel tank pressure sensor value while the engine is running with positive pressure condition.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value lift: Output value (Decimal) x 0.001526 (%) The lowest limit value lift: Not applicable The highest limit value lift: Output value (Decimal) x 0.001526 (%)

DTC P145A, P145D: Monitor ID $3D: Test ID $BB

OBD Monitor ID$3DTest ID$BCUnit and Scaling ID$10
DTCP145B
Test DescriptionPurge flow and/or check valve check by monitoring fuel tank pressure sensor value while the engine is running.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value lift: Output value (Decimal) x 1 (msec.) The lowest limit value lift: Output value (Decimal) x 1 (msec.) The highest limit value lift: Not applicable

DTC P145B: Monitor ID $3D: Test ID $BC

Fuel System (Bank 1)

OBD Monitor ID$81Test ID$D8Unit and Scaling ID$05
DTCP0171, P0172
Test DescriptionMonitoring long-term fuel trim value calculated by A/F sensor.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.0000305 The lowest limit value: Output value (Decimal) x 0.0000305 The highest limit value: Output value (Decimal) x 0.0000305

DTC P0171, P0172: Monitor ID $81: Test ID $D8

Fuel System (Bank 2)

OBD Monitor ID$82Test ID$D8Unit and Scaling ID$05
DTCP0174, P0175
Test DescriptionMonitoring long-term fuel trim value calculated by A/F sensor.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 0.0000305 The lowest limit value: Output value (Decimal) x 0.0000305 The highest limit value: Output value (Decimal) x 0.0000305

DTC P0174, P0175: Monitor ID $82: Test ID $D8

Misfire

OBD Monitor ID$A2Test ID$0CUnit and Scaling ID$24
DTCP0301
Test DescriptionMisfire counters in #1 cylinder for the last 200 revolutions.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (time) The lowest limit value: Not applicable The highest limit value: Not applicable
NOTE: This is not the total number of misfire for the drive cycle.
NOTE
This is not the total number of misfire for the drive cycle.

DTC P0301: Monitor ID $A2: Test ID $0C

OBD Monitor ID$A3Test ID$0CUnit and Scaling ID$24
DTCP0302
Test DescriptionMisfire counters in #2 cylinder for the last 200 revolutions.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (time) The lowest limit value: Not applicable The highest limit value: Not applicable
NOTE: This is not the total number of misfire for the drive cycle.
NOTE
This is not the total number of misfire for the drive cycle.

DTC P0302: Monitor ID $A3: Test ID $0C

OBD Monitor ID$A4Test ID$0CUnit and Scaling ID$24
DTCP0303
Test DescriptionMisfire counters in #3 cylinder for the last 200 revolutions.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (time) The lowest limit value: Not applicable The highest limit value: Not applicable
NOTE: This is not the total number of misfire for the drive cycle.
NOTE
This is not the total number of misfire for the drive cycle.

DTC P0303: Monitor ID $A4: Test ID $0C

OBD Monitor ID$A5Test ID$0CUnit and Scaling ID$24
DTCP0304
Test DescriptionMisfire counters in #4 cylinder for the last 200 revolutions.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (time) The lowest limit value: Not applicable The highest limit value: Not applicable
NOTE: This is not the total number of misfire for the drive cycle.
NOTE
This is not the total number of misfire for the drive cycle.

DTC P0304: Monitor ID $A5: Test ID $0C

OBD Monitor ID$A6Test ID$0CUnit and Scaling ID$24
DTCP0305
Test DescriptionMisfire counters in #5 cylinder for the last 200 revolutions.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (time) The lowest limit value: Not applicable The highest limit value: Not applicable
NOTE: This is not the total number of misfire for the drive cycle.
NOTE
This is not the total number of misfire for the drive cycle.

DTC P0305: Monitor ID $A6: Test ID $0C

OBD Monitor ID$A7Test ID$0CUnit and Scaling ID$24
DTCP0306
Test DescriptionMisfire counters in #6 cylinder for the last 200 revolutions.
Store TimingNormal judgement/Failure judgement
Conversion to Engineering UnitsMeasured value: Output value (Decimal) x 1 (time) The lowest limit value: Not applicable The highest limit value: Not applicable
NOTE: This is not the total number of misfire for the drive cycle.
NOTE
This is not the total number of misfire for the drive cycle.

DTC P0306: Monitor ID $A7: Test ID $0C